Differential Diagnosis of Parkinson Disease, Essential Tremor, and Enhanced Physiological Tremor with the Tremor Analysis of EMG
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index; none of the 7 sources its claims cite is checked for support yet.
Abstract
We investigate the differential diagnostic value of tremor analysis of EMG on Parkinson's disease (PD), essential tremor (ET), and enhanced physiological tremor (EPT). Clinical data from 25 patients with PD, 20 patients with ET, and 20 patients with EPT were collected. The tremor frequency and muscle contraction pattern of the resting, posture, and 500 g and 1000 g overload were recorded. The frequency of PD tremor was 4-6 Hz, and the frequency of ET was also in this range; the frequency of EPT is 6-12 hz having some overlap with PD. The muscle contraction patterns of the ET and EPT group were mainly synchronous contraction, and the muscle contraction mode of the PD group was mainly alternating contraction. Having tremor latency from rest to postural position and having changes in tremor amplitude after mental concentration in PD might distinguish ET. Tremor analysis of EMG was able to distinguish PD from ET and EPT by varying the tremor frequency and muscle contraction pattern. It can also differentiate between PD and ET by the latency and concentration effect and ET and EPT by weight load effect.
Overview
CoChat Summary
TL;DR
This study evaluated tremor analysis of EMG as a way to distinguish Parkinson disease (PD), essential tremor (ET), and enhanced physiological tremor (EPT). In 25 PD, 20 ET, and 20 EPT patients, EMG features such as frequency, muscle contraction pattern, latency, mental concentration effect, and weight loading helped separate these tremor types.
Key findings
- Tremor frequency overlapped between PD and ET: PD tremor was 4–6 Hz and ET tremor was also about 5–8 Hz; EPT was 6–12 Hz and had some overlap with PD.
- Muscle contraction patterns differed: PD was mainly alternating contraction, while ET and EPT were mainly synchronous contraction.
- PD showed tremor latency when moving from rest to posture and increased tremor amplitude with mental concentration, which the authors say can help distinguish PD from ET.
- EPT tremor frequency was significantly reduced by weight load, with a reduction of about 50%; the authors say this helps distinguish ET from EPT.
Methods
- Clinical data were collected from January 2015 to November 2015 at Aviation General Hospital from 25 PD, 20 ET, and 20 EPT patients.
- Tremor was recorded with a Medelec Synergy EMG machine using surface electrodes over the flexor carpi ulnaris and extensor carpi ulnaris, at rest, posture, and with 500 g and 1000 g loads; each recording lasted 30 s.
- Tremor frequency and amplitude were analyzed with TRAS software, and group comparisons used the t-test in SPSS 16 with P < 0.05 considered significant.
Limitations
- The authors explicitly state that the study had a small sample size and that further large-sample research is needed.
- The text also makes evident that the study was single-center and based on a relatively short collection period; this is not stated as a limitation by the authors, but it is clear from the methods.
- The paper does not report detailed outcome tables in the provided text section, so some results are summarized qualitatively in the narrative; this is an evident reporting limitation in the supplied text.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
0 Valid · 0 Not valid · 6 Not checked · 23 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The tremor frequency of ET patients at rest, posture, and weight was about 5–8 Hz.”
§ Differential Diagnosis of Parkinson Disease, Essential Tremor, and Enhanced Physiological Tremor with the Tremor Analysis of EMG > 3. Result
plainn = 20- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The muscle contraction patterns of the ET and EPT group were mainly synchronous contraction”
- Also stated in: § 3. Result · plain
“ET was for synchronization (Figure 2)”
- Also stated in: § 4. Discussion · plain
“ET muscle contraction was mainly synchronous contraction”
§ Differential Diagnosis of Parkinson Disease, Essential Tremor, and Enhanced Physiological Tremor with the Tremor Analysis of EMG > Abstract
plainn = 20- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
- Also stated in: § 3. Result · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Compared with the ET and EPT groups, postural tremor in PD patients was significantly delayed”
- Also stated in: § 4. Discussion · plain
“PD had obvious delay”
§ Differential Diagnosis of Parkinson Disease, Essential Tremor, and Enhanced Physiological Tremor with the Tremor Analysis of EMG > 3. Result
plainstates an associationn = 25- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
- Also stated in: § 4. Discussion · plain
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“mental activity significantly increased the amplitude of PD tremor”
- Also stated in: § 4. Discussion · hedged
“if there was postural tremor in PD patients, most would have increased tremor amplitude during mental activity”
§ Differential Diagnosis of Parkinson Disease, Essential Tremor, and Enhanced Physiological Tremor with the Tremor Analysis of EMG > 3. Result
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
- Also stated in: § 4. Discussion · hedged
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“we found no delay of postural tremor from resting to lifting upper limb in ET”
§ Differential Diagnosis of Parkinson Disease, Essential Tremor, and Enhanced Physiological Tremor with the Tremor Analysis of EMG > 4. Discussion
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
16 more claims
Create a free account to see all 29 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 6
- The quote only partly states this claim. 1
- Probably not a substantial claim. 2
Citations
Cites
Cohen, O., Pullman, S., Jurewicz, E., Watner, D., & Louis, E. D. (2003) · Archives of Neurology · doi:10.1001/archneur.60.3.405 · Cited by 298 · cited 1×
“Traditionally, PD is equal to resting tremor, and ET is postural tremor, which is quite one-sided [7].”
BackgroundHutchison, W. D., Lozano, A. M., Tasker, R. R., Lang, A. E., & Dostrovsky, J. O. (1997) · Experimental Brain Research · doi:10.1007/pl00005606 · Cited by 222 · cited 1×
“The origin of the tremor of PD is located in the globus pallidus; some scholars believe that the subthalamic nucleus hyperexcitability leads to increased number of cells in the posterior part of the globus pallidus [10].”
BackgroundClinical Criteria for the Diagnosis of Parkinson’s Disease
Reichmann, H. (2010) · Neurodegenerative Diseases · doi:10.1159/000314478 · Cited by 145 · cited 1×
“On the other hand, tremor at rest is not pathognomonic for PD [2], for it has been observed in ET [3].”
BackgroundEssential pitfalls in “essential” tremor
Espay, A. J., Lang, A. E., Erro, R., Merola, A., Fasano, A., Berardelli, A., & Bhatia, K. P. (2017) · Movement Disorders · doi:10.1002/mds.26919 · Cited by 102
Beutin, L., Strauch, E., & Fischer, I. (1999) · The Lancet · doi:10.1016/s0140-6736(99)00961-7 · Cited by 85
Comparison of clinical vs. electrophysiological methods of diagnosing of essential tremor
Louis, E. D., & Pullman, S. L. (2001) · Movement Disorders · doi:10.1002/mds.1144 · Cited by 82 · cited 1×
“The diagnosis of PD and its differentiation from other types of tremor such as ET and EPT are frequently difficult [1].”
BackgroundGenetics of essential tremor: Meta-analysis and review
Kuhlenbäumer, G., Hopfner, F., & Deuschl, G. (2014) · Neurology · doi:10.1212/wnl.0000000000000211 · Cited by 74
Gironell, A., Kulisevsky, J., Pascual-Sedano, B., & Barbanoj, M. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200411000-00009 · Cited by 59 · cited 2×
“of PD, in which rest tremor, bradykinesia, rigidity, and postural stability may be slight or inexistent [8].”
BackgroundA software for recording and analysis of human tremor
Lauk, M., Timmer, J., Lücking, C. H., Honerkamp, J., & Deuschl, G. (1999) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(99)00012-7 · Cited by 56 · cited 1×
“TheMedelec Synergy EMGmachine of Oxford company was used in this study with 4 EMG surface electrodes and 1 pressure accelerator [6].”
MethodBoose, A., Spieker, S., Jentgens, C., & DICHGANS, J. (1996) · Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control · doi:10.1016/0924-980x(96)95533-2 · Cited by 44 · cited 1×
“But some scholars believe that the pattern of muscle contraction can show different burst at different times by long-term recording [9].”
Background
Research works printed but not linked: 4
- 2010, Neurodegenerative Diseases, 7, 284
- 1984, Tremor and rhythmical involuntary movements in Parkinsons diease, 295
- 1999, Lancet, 353, 1498
- 2014, Neurology, 82, 176
Cited by
Shawen, N., O’Brien, M. K., Venkatesan, S., Lonini, L., Simuni, T., Hamilton, J. L., Ghaffari, R., Rogers, J. A., & Jayaraman, A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00684-4 · Cited by 116
“Previous studies have noted that characteristic PD tremor frequency is 4–6 Hz [28, 29], but may have additional frequency components in the range 1–30 Hz [29].”
BackgroundKumar, S., Goyal, L., & Singh, S. (2021) · CNS & Neurological Disorders - Drug Targets · doi:10.2174/1871527320666211006142100 · Cited by 97
Essential Tremor and Parkinson’s Disease: Exploring the Relationship
Tarakad, A., & Jankovic, J. J. (2018) · Europe PMC (PubMed Central) · doi:10.7916/d8md0gvr · Cited by 58
“Some electrophysiologic studies have also found distinctions between the two conditions including that the muscle contractions in patients with rest tremor associated with ET are mainly synchronous whereas those in PD-related rest tremor are mainly alternating, though these patterns do not always differentiate the two…”
Resultvan der Veen, S., Klamer, M. R., Elting, J. W. J., Koelman, J. H. T. M., van der Stouwe, A. M. M., & Tijssen, M. A. J. (2021) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2021.07.033 · Cited by 57
Hashim, H. A., Mohammed, S. L., & Gharghan, S. K. (2020) · Measurement · doi:10.1016/j.measurement.2020.107573 · Cited by 54
Essential tremor: Clinical perspectives and pathophysiology
Pan, M., & Kuo, S. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120198 · Cited by 56
Verri, É. D., da Silva, G. P., Fioco, E. M., da Silva, N. S., Fabrin, S., Zanella, C. A. B., Garrefa, C. R., Faria, M., Siéssere, S., Hallak, J. E. C., et al. (2019) · Journal of Oral Rehabilitation · doi:10.1111/joor.12824 · Cited by 38
Tremor-Suppression Orthoses for the Upper Limb: Current Developments and Future Challenges
Nguyen, S. H., & Luu, T. P. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.622535 · Cited by 40
Evolving Landscape of Parkinson’s Disease Research: Challenges and Perspectives
Tenchov, R., Sasso, J. M., & Zhou, Q. A. (2025) · ACS Omega · doi:10.1021/acsomega.4c09114 · Cited by 45
Evaluation of rest tremor in different positions in Parkinson’s disease and essential tremor plus
Nisticò, R., Quattrone, A., Crasà, M., Maria, M. D., Vescio, B., & Quattrone, A. (2022) · Neurological Sciences · doi:10.1007/s10072-022-05885-4 · Cited by 24
Distinguishing essential tremor from Parkinson’s disease: clinical and experimental tools
Angelini, L., Paparella, G., & Bologna, M. (2024) · Expert Review of Neurotherapeutics · doi:10.1080/14737175.2024.2372339 · Cited by 24
“Postural tremor in PD is significantly delayed from rest to lifting of the upper limbs in a large percentage of patients, although not in all, and mental activity significantly increases the amplitude of tremor especially in PD [13,81].”
Gauthier-Lafrenière, E., Aljassar, M., Rymar, V. V., MILTON, J. G., & Sadikot, A. F. (2022) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2022.878279 · Cited by 22
“These include electromyograms that assess changes in voltage over active muscle groups as a surrogate for tremor amplitude and frequency (Breit et al., 2008; Zhang et al., 2017), electromagnetic motion capture (Charles et al.”
BackgroundChang, C., Tsai, C., Lu, M., Tseng, H.-C., Lu, G., Liu, B.-L., & Lin, H.-C. (2022) · BMC Complementary Medicine and Therapies · doi:10.1186/s12906-021-03481-1 · Cited by 17
Quattrone, A., Zappia, M., & Quattrone, A. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1460576 · Cited by 17
“…through visual evaluation of surface EMG recordings, usually performed by neurologists or expert technicians, and classified as synchronous (when antagonist muscles contract at the same time) or alternating (when the bursts of antagonist muscles are shifted), as shown in Figure 2 (74, 81, 87).”
BackgroundRest Tremor Pattern Predicts DaTscan ( 123I‐Ioflupane ) Result in Tremulous Disorders
Quattrone, A., Nisticò, R., Morelli, M., Arabia, G., Crasà, M., Vescio, B., Mechelli, A., Cascini, G. L., & Quattrone, A. (2021) · Movement Disorders · doi:10.1002/mds.28797 · Cited by 14
Characteristics of Tremor Induced by Lesions of the Cerebellum
Kovács, A., Kiss, M., Pinter, N. K., Szirmai, I. G., & Kamondi, A. (2019) · The Cerebellum · doi:10.1007/s12311-019-01027-3 · Cited by 14
“tion tremor [2] with a peak frequency of 5–9 Hz [70, 71], while acute cerebellar tremor is present only ipsilaterally to the lesion and it has lower peak frequency (below 3 Hz).”
BackgroundThe Rehapiano—Detecting, Measuring, and Analyzing Action Tremor Using Strain Gauges
Ferenčík, N., Jaščur, M., Bundzel, M., & Cavallo, F. (2020) · Sensors · doi:10.3390/s20030663 · Cited by 11
Kılınç, B., Cetisli-Korkmaz, N., Bir, L. S., Marangoz, A. D., & Şenol, H. (2023) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2023.2236691 · Cited by 10
“EMG has proven to be a reliable method to distinguish different types of tremor, measure the pathological tremors and the changes that occur under the influence of weight loading or concentration (Spieker, Jentgens, Boose, and Dichgans, 1995; Zhang, Xing, Ma, and Feng, 2017).”
Multimodal imaging and electrophysiological study in the differential diagnosis of rest tremor
Aracri, F., Quattrone, A., Bianco, M. G., Sarica, A., Maria, M. D., Calomino, C., Crasà, M., Nisticò, R., Buonocore, J., Vescio, B., et al. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1399124 · Cited by 9
Sanderson, J. B., Yu, J. Y. H., Liu, D. D., Amaya, D. E., Lauro, P. M., D’Abreu, A., Akbar, U., Lee, S., & Asaad, W. F. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00886 · Cited by 10
Tremor: Clinical Frameworks, Network Dysfunction and Therapeutics
Ortega‐Robles, E., & Arias-Carrión, Ó. (2025) · Brain Sciences · doi:10.3390/brainsci15080799 · Cited by 13
“Loading the limb with a 500–1000 g weight often results in a notable reduction in tremor frequency, observed in 42% of patients with EPT, whereas such a response is rare in other tremor types [90].”
Sushkova, O. S., Morozov, A. A., Kershner, I. A., Khokhlova, M., Gabova, A. V., Karabanov, A. V., Chigaleichick, L. A., & Illarioshkin, S. N. (2023) · Sensors · doi:10.3390/s23031531 · Cited by 10
Wu, H., Zhang, Y., Wu, X. L., & Yang, F. (2020) · International Conference on Automation, Control and Robotics Engineering (CACRE) · doi:10.1109/cacre50138.2020.9230024 · Cited by 10
Real-time classification of movement patterns of tremor patients
Piepjohn, P., Bald, C., Kuhlenbäumer, G., Becktepe, J. S., Deuschl, G., & Schmidt, G. (2022) · Biomedical Engineering / Biomedizinische Technik · doi:10.1515/bmt-2021-0140 · Cited by 5
Targeting the fundamentals for tremors: the frequency and amplitude coding in essential tremor
Pan, M. (2025) · Journal of Biomedical Science · doi:10.1186/s12929-024-01112-8 · Cited by 11
Model-based closed-loop control of thalamic deep brain stimulation
Tian, Y., Saradhi, S., Bello, E. M., Johnson, M. D., D’Eleuterio, G. M. T., Popović, M. R., & Lankarany, M. (2024) · Frontiers in Network Physiology · doi:10.3389/fnetp.2024.1356653 · Cited by 12
“The parameters K p , K i , and K d of the PID controller were chosen to be 10 3 (Hz/mV 2 ), 10 5 Hz/(mV 2 · min), and 5 × 10 3 (Hz · min/mV 2 ), respectively; parameter tuning was performed to increase the ef fi cacy of the controller (Supplementary Figure S2 and Supplementary Note).”
BackgroundMethodA Miniaturized Flexible Surface Electromyography Sensor With an Integrated Localization Concept
Balbach, S., Kolpak, J., Dorn, C., Brückner, S., Schlechtweg, N., Gambietz, M., Koelewijn, A. D., Vossiek, M., & Hagelauer, A. (2025) · IEEE Microwave Magazine · doi:10.1109/mmm.2024.3494717 · Cited by 5
“For example, sEMG measurements allow to differentiate from among different types of tremors in PD [11].”
Jensen, B. R., Malling, A. S. B., Morberg, B. M., Gredal, O., Bech, P., & Wermuth, L. (2018) · Case Reports in Neurology · doi:10.1159/000492486 · Cited by 4
Validation and Discussion of Severity Evaluation and Disease Classification Using Tremor Video
Hayashida, T., Sugiyama, T., Sakai, K., Ishii, N., Mochizuki, H., & Zin, T. T. (2023) · Electronics · doi:10.3390/electronics12071674 · Cited by 2
Chen, J., Zhou, X., Lü, Q., Jin, L., & Huang, Y. (2021) · Neurological Sciences · doi:10.1007/s10072-021-05053-0 · Cited by 2
Tarianyk, K. А. (2021) · World of Medicine and Biology · doi:10.26724/2079-8334-2021-4-78-160-165 · Cited by 2
Parkinsonian hand tremor characterization from magnified video sequences
Martínez, F., Contreras-Corredor, S. A., & Acosta, I. S. (2018) · International Symposium on Medical Information Processing and Analysis (SIPAIM) · doi:10.1117/12.2512109 · Cited by 2
Zhu, H., Tan, Z., Li, Y., Sun, Q., & Qi, H. (2025) · Sensor Review · doi:10.1108/sr-06-2025-0418 · Cited by 2
Kumar, V. V., Sivaji, A. R., Singh, S., et al. (2025) · Epileptic Disorders · doi:10.1002/epd2.70035 · Cited by 1
Model-Based Closed-Loop Control of Thalamic Deep Brain StimulationPreprint
Tian, Y., Saradhi, S., Bello, E. M., et al. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.12.20.572569 · Cited by 1
najim, N. S., Ameer, A. H., & Mohammed, A. A. (2022) · Journal of the Faculty of Medicine Baghdad · doi:10.32007/jfacmedbagdad.6421921 · Cited by 1
“%) of enhanced physiological tremor and physiological tremor patients, was a synchronized pattern with more fine low amplitude muscle bursts as illustrated in Figures (2), and (3).”
BackgroundInfluentialSong, C., Park, C., Lee, J., Kim, H., Kang, J., Lee, B., Park, C., Kim, J., Lee, H., Lee, Y. J., et al. (2026) · Advancement of science · doi:10.1002/advs.76724
Evolution and trends in tremor diagnosis and differential diagnosis—a bibliometric study
Liu, J., Xu, X., Liu, J., Bian, R., Zheng, J., Dong, K., Zhu, X., & Xh, C. (2026) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2026.1829580
Feature Extraction to Classify Parkinsonian Tremor in EMG Signals
Krishnan, S. R. A., Maiti, R., Chandra, S., & Biswas, A. (2025) · Lecture notes in mechanical engineering · doi:10.1007/978-981-96-6414-6_22
Early Detection of Parkinson’s Disease Using Machine Learning and Wearable Sensors
Biju, S. M., Chawla, M. D., & Al-Khatib, O. (2025) · Lecture notes in networks and systems · doi:10.1007/978-981-96-9242-2_44
A Review on Internet of Things (IoT): Parkinson’s Disease Monitoring Device
Lokeshwari, J., & Kumar, R. S. (2024) · Lecture notes in networks and systems · doi:10.1007/978-3-031-61929-8_10
Daneault, J., & Duval, C. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_7
Superficial Electromyographic Signal Segmentation Through Spectral EntropyPreprint
Mendez-Moreno, S., Espinosa, L., Vital-Ochoa, O., Espinosa‐Tanguma, R., & Acosta‐Elías, J. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4183377
Analyzing the Effect of Visual Cue on Physiological Hand Tremor Using Wearable Accelerometer Sensors
Kannan, V., Adalarasu, K., Natarajan, P., & Balasubramanian, V. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-74614-8_66
L’analyse de signaux EMG et leur application au diagnostic de la maladie de Parkinson
Bengacemi, H. (2021) · theses.fr (ABES) · doi:10.70675/c9e9d83azeffez4851zbe06z6e079bd7ee64
Verri, É. D. (2018) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.58.2018.tde-23022018-143734
Metadata
- Authors
- Zhang, J., Xing, Y., Ma, X., & Feng, L.
- Affiliations
- Aviation General Hospital (CN)
- Capital Medical University (CN)
- Corresponding author
- Zhang, Jie
- Venue
- Parkinson's Disease
- Publisher
- Wiley
- Published
- 2017
- Volume
- 2017
- Pages
- 1-4
- ISSN
- 2042-0080 (ISSN-L)
- 2090-8083
- PMC
- PMC5573102
- OpenAlex
- W2749605746
- Semantic Scholar
- ded3175bff456265fad3968c81f249f88f2e55c8
- Cited by
- 47
- References
- 11
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 5 · 2023: 4 · 2022: 7 · 2021: 8 · 2020: 5 · 2019: 2 · 2018: 4
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Parkinson s Disease (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- Parkinson's disease, essential tremor, tremor analysis, electromyography, differential diagnosis, tremor frequency, muscle contraction patterns, postural tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.

