Cited by 22Non-Invasive Vital Sign MonitoringOptical Imaging and Spectroscopy TechniquesAnalytical Chemistry and Sensors

The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare

Open access
Baek, Hyun Jae, Shin, JaeWook, Cho, Jaegeol·2018·Journal of Healthcare Engineering

Abstract

According to the theoretical equation of the pulse oximeter expressed by the ratio of amplitude (AC) and baseline (DC) obtained from the photoplethysmographic signal of two wavelengths, the difference of the amount of light absorbed depending on the melanin indicating the skin color is canceled by normalizing the AC value to the DC value of each wavelength. Therefore, theoretically, skin color does not affect the accuracy of oxygen saturation measurement. However, if there is a direct path for the light emitting unit to the light receiving unit instead of passing through the human body, the amount of light reflected by the surface of the skin changes depending on the color of the skin. As a result, the amount of crosstalk that varies depending on the skin color affects the ratio of AC to DC, resulting in errors in the calculation of the oxygen saturation value. We made crosstalk sensors and crosstalk-free sensors and performed desaturation experiments with respiratory gas control on subjects with various skin colors to perform oxygen saturation measurements ranging from 60 to 100%. Experimental results showed that there was no difference in the measurement error of oxygen saturation according to skin color in the case of the sensor which prevented crosstalk (-0.8824 ± 2.2859 for Asian subjects, 0.6741 ± 3.2822 for Caucasian subjects, and 0.9669 ± 2.2268 for African American subjects). However, a sensor that did not prevent crosstalk showed a large error in dark skin subjects (0.8258 ± 2.1603 for Asian subjects, 0.8733 ± 1.9716 for Caucasian subjects, and -3.0591 ± 3.9925 for African Americans). Based on these results, we reiterate the importance of sensor design in the development of pulse oximeters using reflectance-type sensors.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2018/3521738

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Baek et al. performed desaturation experiments at 60% to 100% on healthy adults with different skin pigmentation; conventional sensors showed a large error in dark-skinned subjects, while the crosstalk-free sensor did not present SpO2 measurement errors according to skin color.

    “Accuracy improvements were found with a crosstalk-free sensor designed by Baek et al. who performed desaturation experiments at 60% to 100% on healthy adults with different skin pigmentation [75]. The conventional sensors showed a large error in dark-skinned subjects, while the sensor which prevented optical crosstalk did not present SpO2 measurement errors according to skin color.”
  • Ancestry descriptors were used in 11 studies (29.73%).

    “On the other hand, ancestry descriptors were used in 11 studies (29.73%) [17,21,23,24,41,51,53,61,75,82,93]”
  • Baek et al. found large errors in the dark-skinned subjects with the pulse oximeter that did not prevent crosstalk.

    “They found large errors in the dark-skinned subjects with the pulse oximeter that did not prevent crosstalk.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 20 · Cited by 22

Research works printed but not linked: 1

  1. [21]Tsai H.-Y. Huang K.-C. Chang H.-C. Chang C.-H. A study on oxygen saturation images constructed from the skin tissue of human hand Proceedings of IEEE International Instrumentation and Measurement Technology Conference (I2MTC) May 2013 Minneapolis, MN, USA 58 62

Authors
Baek, H. J., Shin, J., & Cho, J.
Affiliations
Soonchunhyang University (KR)
Corresponding author
Cho, Jaegeol
Venue
Journal of Healthcare Engineering
Publisher
Wiley
Published
2018-10-21
Volume
2018
Pages
1-8
ISSN
  • 2040-2295 (ISSN-L)
  • 2040-2309
OpenAlex
W2897310138
Cited by
22
References
20
Citations by year
2026: 1 · 2025: 2 · 2024: 5 · 2023: 4 · 2022: 4 · 2021: 3 · 2020: 2 · 2019: 1
FWCI
0.60
Type
journal article
Language
en
Open access
Locations
  • Journal of Healthcare Engineering (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Soonchunhyang University
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
pulse oximetry, optical crosstalk, skin color, oxygen saturation measurement, photoplethysmography, melanin, mobile health, measurement error
MeSH terms
Fingers, Humans, Oximetry, Oxygen, Signal Processing, Computer-Assisted, Skin Pigmentation, Photoplethysmography, Telemedicine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review