The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Cobb Angle Measurement of Spine from X-Ray Images Using Convolutional Neural Network
Open accessAbstract
Scoliosis is a common spinal condition where the spine curves to the side and thus deforms the spine. Curvature estimation provides a powerful index to evaluate the deformation severity of scoliosis. In current clinical diagnosis, the standard curvature estimation method for assessing the curvature quantitatively is done by measuring the Cobb angle, which is the angle between two lines, drawn perpendicular to the upper endplate of the uppermost vertebra involved and the lower endplate of the lowest vertebra involved. However, manual measurement of spine curvature requires considerable time and effort, along with associated problems such as interobserver and intraobserver variations. In this article, we propose an automatic system for measuring spine curvature using the anterior-posterior (AP) view spinal X-ray images. Due to the characteristic of AP view images, we first reduced the image size and then used horizontal and vertical intensity projection histograms to define the region of interest of the spine which is then cropped for sequential processing. Next, the boundaries of the spine, the central spinal curve line, and the spine foreground are detected by using intensity and gradient information of the region of interest, and a progressive thresholding approach is then employed to detect the locations of the vertebrae. In order to reduce the influences of inconsistent intensity distribution of vertebrae in the spine AP image, we applied the deep learning convolutional neural network (CNN) approaches which include the U-Net, the Dense U-Net, and Residual U-Net, to segment the vertebrae. Finally, the segmentation results of the vertebrae are reconstructed into a complete segmented spine image, and the spine curvature is calculated based on the Cobb angle criterion. In the experiments, we showed the results for spine segmentation and spine curvature; the results were then compared to manual measurements by specialists. The segmentation results of the Residual U-Net were superior to the other two convolutional neural networks. The one-way ANOVA test also demonstrated that the three measurements including the manual records of two different physicians and our proposed measured record were not significantly different in terms of spine curvature measurement. Looking forward, the proposed system can be applied in clinical diagnosis to assist doctors for a better understanding of scoliosis severity and for clinical treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distinctive Image Features from Scale-Invariant Keypoints
Lowe, D. G. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000029664.99615.94 · Cited by 55,589
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190
THE DISTRIBUTION OF THE FLORA IN THE ALPINE ZONE. 1
Jaccard, P. (1912) · New Phytologist · doi:10.1111/j.1469-8137.1912.tb05611.x · Cited by 4,561
Road Extraction by Deep Residual U-Net
Zhang, Z., Liu, Q., & Wang, Y. (2018) · IEEE Geoscience and Remote Sensing Letters · doi:10.1109/lgrs.2018.2802944 · Cited by 3,179 · cited 3×
“-ese results reveal that the performance of our proposed work is very close to the one in [24] and should be better than the abovementioned methods [21–23].”
MethodResultRegression Towards Mediocrity in Hereditary Stature.
Galton, F. (1886) · The Journal of the Anthropological Institute of Great Britain and Ireland · doi:10.2307/2841583 · Cited by 1,454
Outlines for the study of scoliosis
Cobb, Cobb, J. L., & Cobb, J. R. (1948) · Journal of Bone and Joint Surgery · Cited by 1,150
Principal Neighborhood Dictionaries for Nonlocal Means Image Denoising
Tasdizen, T. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2028259 · Cited by 235
The role of measurement reliability in clinical trials
Lachin, J. M. (2004) · Clinical Trials · doi:10.1191/1740774504cn057oa · Cited by 234
Zhang, J., Li, H., Lv, L., et al. (2017) · International Journal of Biomedical Imaging · doi:10.1155/2017/9083916 · Cited by 85
Cited by
Using deep transfer learning to detect scoliosis and spondylolisthesis from x-ray images
Fraiwan, M., Audat, Z., Fraiwan, L., & Manasreh, T. (2022) · PLOS ONE · doi:10.1371/journal.pone.0267851 · Cited by 90
Metadata
- Authors
- Horng, M.-H., Kuok, C.-P., Fu, M.-J., Lin, C.-J., & Sun, Y.-N.
- Venue
- Computational and Mathematical Methods in Medicine
- Publisher
- Wiley
- Published
- 2019-02-19
- Volume
- 2019
- Pages
- 1-18
- ISSN
- 1748-670X (ISSN-L)
- 1748-6718
- OpenAlex
- W2916452242
- Cited by
- 305
- References
- 14
- FWCI
- 8.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cobb Angle Measurement of Spine from X-Ray Images Using Convolutional Neural Network. https://app.cochat.ai/papers/10.1155/2019/6357171
- The paper
- Horng, M.-H., Kuok, C.-P., Fu, M.-J., Lin, C.-J., & Sun, Y.-N. (2019). Cobb Angle Measurement of Spine from X-Ray Images Using Convolutional Neural Network. Computational and Mathematical Methods in Medicine. https://doi.org/10.1155/2019/6357171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.