Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 305

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Cobb Angle Measurement of Spine from X-Ray Images Using Convolutional Neural Network

Open access
Horng, Ming-Huwi, Kuok, Chan-Pang, Fu, Min-Jun, Lin, Chii-Jen, Sun, Yung-Nien·2019·Computational and Mathematical Methods in Medicine

Abstract

Scoliosis is a common spinal condition where the spine curves to the side and thus deforms the spine. Curvature estimation provides a powerful index to evaluate the deformation severity of scoliosis. In current clinical diagnosis, the standard curvature estimation method for assessing the curvature quantitatively is done by measuring the Cobb angle, which is the angle between two lines, drawn perpendicular to the upper endplate of the uppermost vertebra involved and the lower endplate of the lowest vertebra involved. However, manual measurement of spine curvature requires considerable time and effort, along with associated problems such as interobserver and intraobserver variations. In this article, we propose an automatic system for measuring spine curvature using the anterior-posterior (AP) view spinal X-ray images. Due to the characteristic of AP view images, we first reduced the image size and then used horizontal and vertical intensity projection histograms to define the region of interest of the spine which is then cropped for sequential processing. Next, the boundaries of the spine, the central spinal curve line, and the spine foreground are detected by using intensity and gradient information of the region of interest, and a progressive thresholding approach is then employed to detect the locations of the vertebrae. In order to reduce the influences of inconsistent intensity distribution of vertebrae in the spine AP image, we applied the deep learning convolutional neural network (CNN) approaches which include the U-Net, the Dense U-Net, and Residual U-Net, to segment the vertebrae. Finally, the segmentation results of the vertebrae are reconstructed into a complete segmented spine image, and the spine curvature is calculated based on the Cobb angle criterion. In the experiments, we showed the results for spine segmentation and spine curvature; the results were then compared to manual measurements by specialists. The segmentation results of the Residual U-Net were superior to the other two convolutional neural networks. The one-way ANOVA test also demonstrated that the three measurements including the manual records of two different physicians and our proposed measured record were not significantly different in terms of spine curvature measurement. Looking forward, the proposed system can be applied in clinical diagnosis to assist doctors for a better understanding of scoliosis severity and for clinical treatments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2019/6357171

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 305

Metadata

Authors
Horng, M.-H., Kuok, C.-P., Fu, M.-J., Lin, C.-J., & Sun, Y.-N.
Venue
Computational and Mathematical Methods in Medicine
Publisher
Wiley
Published
2019-02-19
Volume
2019
Pages
1-18
ISSN
  • 1748-670X (ISSN-L)
  • 1748-6718
OpenAlex
W2916452242
Cited by
305
References
14
FWCI
8.29
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cobb Angle Measurement of Spine from X-Ray Images Using Convolutional Neural Network. https://app.cochat.ai/papers/10.1155/2019/6357171
The paper
Horng, M.-H., Kuok, C.-P., Fu, M.-J., Lin, C.-J., & Sun, Y.-N. (2019). Cobb Angle Measurement of Spine from X-Ray Images Using Convolutional Neural Network. Computational and Mathematical Methods in Medicine. https://doi.org/10.1155/2019/6357171

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.