The Accuracy of Computer-Assisted Implant Surgery Performed Using Fully Guided Templates versus Pilot-Drill Guided Templates
Open accessThe DOI matches its Crossref record.
Abstract
Purpose. Computer-assisted stereolithographically guided surgery allows an ideal implant placement for prosthetic restoration. Two types of stereolithographic templates are currently available: a fully guided template and a pilot-drill guided template. The purpose of this study was (i) to evaluate the accuracy of implant insertion using these types of surgical templates and (ii) to define parameters influencing accuracy. Materials and Methods. 20 patients were enrolled and divided into 2 study groups: in group A, implants were placed using CAD-CAM templates with fully guided sleeves; in group B, implants were placed with a template with only pilot-drill guided sleeves. Pre- and postoperative computed tomographies were used to measure differences between final positions of implants and virtually planned positions. Three linear discrepancies (coronal, apical, and depth) and two angular ones (buccolingual and mesiodistal) were measured. Correlations between accuracy and jaws of interest, implant length and diameters, and type of edentulism were also analysed. Results. A total of 50 implants were inserted in 15 patients using CAD-CAM templates: 23 implants in group A and 27 in group B. The mean coronal deviations were 1.16 and 1.11 mm (P = 0.35), respectively; the mean apical deviations were 1.65 and 1.71 mm (P = 0.22); the mean depth deviations were 0.95 and −0.68 mm (P = 0.032); the mean buccolingual angular deviations were 4.16° and 6.72° (P = 0.042); and the mean mesiodistal ones were 2.81° and 5.61° (P = 0.029). In addition, the accuracy was statistically influenced only by implant diameter for coronal discrepancy (P = 0.035) and by jaw of interest for mesiodistal angulation (P = 0.045). Conclusion. Fully guided implant surgery was more accurate than pilot-drill guided surgery for different parameters. For both types of surgery, a safety margin of at least 2mm should be preserved during implant planning to prevent damage to nearby anatomical structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sharifi-Rad, M., Anil Kumar, N. V., Zucca, P., Varoni, E. M., Dini, L., Panzarini, E., Rajkovic, J., Tsouh Fokou, P. V., Azzini, E., Peluso, I., et al. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00694 · Cited by 1,971
Kashyap, P., Shikha, D., Thakur, M., & Aneja, A. (2022) · Journal of Food Biochemistry · doi:10.1111/jfbc.13950 · Cited by 177
Assistive Technologies in Dementia Care: An Updated Analysis of the Literature
Pappadà, A., Chattat, R., Chirico, I., Valente, M., & Ottoboni, G. (2021) · Frontiers in Psychology · doi:10.3389/fpsyg.2021.644587 · Cited by 131
Alzheimer’s Disease, Inflammation, and the Role of Antioxidants
Sinyor, B., Mineo, J., & Ochner, C. (2020) · Journal of Alzheimer s Disease Reports · doi:10.3233/adr-200171 · Cited by 120
Metadata
- Authors
- De Santis, D., Malchiodi, L., Cucchi, A., Cybulski, A., Verlato, G., Gelpi, F., & Nocini, P. F.
- Venue
- BioMed Research International
- Publisher
- Wiley
- Published
- 2019-04-08
- Volume
- 2019
- Pages
- 1-10
- ISSN
- 1110-7243 (ISSN-L)
- 2314-6133
- 2314-6141
- OpenAlex
- W2939430874
- Cited by
- 119
- References
- 0
- FWCI
- 29.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Accuracy of Computer-Assisted Implant Surgery Performed Using Fully Guided Templates versus Pilot-Drill Guided Templates. https://app.cochat.ai/papers/10.1155/2019/9023548
- The paper
- De Santis, D., Malchiodi, L., Cucchi, A., Cybulski, A., Verlato, G., Gelpi, F., & Nocini, P. F. (2019). The Accuracy of Computer-Assisted Implant Surgery Performed Using Fully Guided Templates versus Pilot-Drill Guided Templates. BioMed Research International. https://doi.org/10.1155/2019/9023548
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.