Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data
Open accessThe DOI matches its Crossref record; 46 of the 51 references it cites were found in a registry or an index; 6 of the 19 sources its claims cite were checked for support.
Abstract
Long-term monitoring of resting tremor is key to assess the status of patients suffering from Parkinson’s disease (PD), which is of vital importance for reasonable medication. The detection and quantification of resting tremor in reported works rely heavily on specified movements and are not appropriate for long-term monitoring in real-life condition. The purpose of this study is to develop a detection model for long-term monitoring of resting tremor and explore an effective indicator for tremor quantification. This study included long-term acceleration data from PD patients and proposed a resting tremor detection model based on machine learning classifiers and Synthetic Minority Oversampling Technique (SMOTE). Four machine learning classifiers, K-Nearest Neighbor (KNN), Random Forest (RF), Adaptive Boosting (AdaBoost), and Support Vector Machine (SVM), were compared. Furthermore, an indicator called tremor timing ratio (TTR) was defined and calculated for tremor quantification. The detection model with RF classifier achieved the highest overall accuracy of 94.81%. The sample entropy of the acceleration signal was proved most influential in the classification by exploring the feature importance. Through the Kruskal-Wallis test and the Mann-Whitney U test, the TTR had a strong correlation with the subscore of resting tremor in Unified Parkinson Disease Rating Scale (UPDRS). Such two-step evaluation process for resting tremor can detect the tremor effectively and is expected to be applied in long-term monitoring of PD patients in daily life to realize a more comprehensive assessment of PD.
Overview
CoChat Summary
TL;DR
This paper develops a two-step evaluation process for Parkinson’s disease resting tremor using long-term wrist acceleration data: a machine-learning detection model and a new quantification indicator, tremor timing ratio (TTR). The Random Forest model achieved 94.81% overall accuracy, and TTR was significantly associated with UPDRS resting tremor subscores.
Key findings
- The Random Forest classifier gave the best detection performance among KNN, RF, AdaBoost, and SVM, with 94.81% overall accuracy, 95.18% sensitivity, 94.44% specificity, 94.83% F1 score, and a Kappa coefficient of 0.90.
- Sample entropy (SampEn) was the most influential feature for classification, followed by signal energy, based on out-of-bag permuted predictor importance in the RF classifier.
- TTR differed significantly across UPDRS resting tremor scores: Kruskal-Wallis p = 0.0034; Mann-Whitney U p = 0.022 for score 1 vs 2, p = 0.0048 for score 1 vs 3, and p = 0.026 for score 2 vs 3. Median TTR values were 0.46 (SD 0.22) for score 1, 0.67 (SD 0.14) for score 2, and 0.85 (SD 0.15) for score 3.
- Under an interpatient paradigm, the RF model still achieved a weighted average accuracy of 89.70%; without preprocessing, RF accuracy fell to 89.38%, a reduction of 5.43%.
Methods
- Long-term triaxial acceleration data were collected from 20 PD patients wearing wrist devices at 100 Hz in home settings, with synchronous video and UPDRS ratings as labels; mean tremor prevalence was 16.9%.
- A 5-second sliding window with 1-second step was used; signals were bandpass filtered at 0.65–12.5 Hz, and five features were extracted: mean amplitude, sample entropy, dominant frequency, energy, and spectrum concentration. SMOTE balanced the dataset, and KNN, RF, AdaBoost, and SVM were compared using fivefold cross-validation.
- For quantification, 8 patients with valid long-term tremor data contributed 33 cases of 15-minute continuous recordings scored as 1, 2, or 3 (9, 18, and 6 cases, respectively); TTR was calculated as detected tremor samples divided by all samples, then tested with Kruskal-Wallis and Mann-Whitney U tests.
Limitations
- The paper states that the main limitation is data size: although long-duration data were collected, the number of subjects is limited and the dataset needs to be extended to verify the findings.
- The paper states that only three resting tremor severity scores were quantified, lacking score 4, because few patients scored 4 while on medication and those diagnosed as 4 were too severe to participate; TTR differences for score 4 were not validated.
- Evident from the text: the quantification sample is small (8 patients, 33 cases), and interpatient detection performance varied widely across patients, with one patient showing only 53.16% accuracy despite the high average accuracy.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
4 Valid · 2 Not valid · 9 Not checked · 56 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Since the frequency of the resting tremor mainly ranges from 4 to 7 Hz [32], the waveform of resting tremor signal was well preserved after filtering.”
§ Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data > 2.3. Preprocessing.
What the sources say
- Partly supportedcites [32] sourceExperimental — accuracy not yet measured
In ‘Step 2: characterise the tremor clinically,’ the paper says Parkinson’s tremor occurs predominantly at rest and has a frequency of 4–7 Hz. That supports the range for Parkinson’s tremor, but not the broader claim that resting tremor in general mainly falls within it. (LLM, conf=0.84)
- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Most of the reported works so far focused on detecting and quantifying resting tremor based on fragments of signals.”
§ Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data > 1. Introduction
What the sources say
- Could not verifycites [29] sourceExperimental — accuracy not yet measured
Our copy of Pereira et al. (2018) contains a related-work survey (Introduction, pp. 67-68) covering Das [6], Spadotto [7,11], Gharehchopogh [10], Memedi [12], Drotár [13,19], Taleb [14], Lones [15], Pan [16], Peker [17], Hariharan [18] and Sadikov [20], but it characterises those works in terms of handwriting kinematics/pressure, feature selection, spirography, dysphonia/biomedical sound and SPECT imaging — no passage states that most focused on detecting or quantifying RESTING tremor, nor on using fragments of signals (searched: 'resting tremor', 'fragments of signals', 'segments', 'previous works limitations'). The only tremor-specific mention is Pan et al. [16] 'to compare the onset of tremors in patients with PD'. If anything, the paper's own method explicitly uses the whole signal ('each sensor outputs the whole signal acquired during the exam', Section 2.1, p. 70), but that is about its approach, not a stated characterisation of prior literature, so the claim can be neither confirmed nor contradicted from our copy. (LLM, conf=0.62)
- Partly supportedcites [30] sourceExperimental — accuracy not yet measured
The Related Work (II, p. 2) supports the general shape of the claim: many works have used IMU sensors for tremor detection, most approaches are restricted to lab/home environments, and the detailed example [24] extracts handcrafted features over 2-second windows with fine-grained, moment-by-moment video labels (i.e. fragments of signals); the Introduction (I, p. 1-2) likewise notes prior works quantifying tremor severity from accelerometer/gyroscope data. However, our copy nowhere states that most reported works focused specifically on RESTING tremor — the one prior study it describes in detail recorded subjects performing walking, writing and chess, and the paper's contrast with prior work is about setting (in-the-wild vs lab/home) and label granularity (coarse subject-level vs fine-grained), not about tremor subtype. The 'resting tremor' qualifier is therefore not supported by this source. (LLM, conf=0.68)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“However, most of the reported studies designed experiments in which the patients were required to do the assigned tasks to induce tremor and record signal for just a few seconds or a few minutes.”
§ Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data > 1. Introduction
What the sources say
- Could not verifycites [17] sourceExperimental — accuracy not yet measured
Our copy of Lacy et al. (2018) contains no survey or characterisation of the wider literature of movement-recording studies, and no passage addresses tremor at all: the word appears nowhere in the indexed text, the study being about finger tapping as a bradykinesia measure (Sections 3.1-3.3). The closest passages describe only this study's own protocol — a thirty-second assigned finger-tapping task, longer than the UPDRS 'ten tap' limit (3.2, and 4.2 'the thirty second recording') — plus general remarks in the Conclusions on wearable sensors and time-series modelling. Nothing in our copy states or contradicts that most reported studies induced tremor and recorded signal for only seconds or minutes (searched: 'tremor', 'assigned tasks to induce tremor and record signal for only a few seconds or minutes', 'recording duration / previous studies / continuous monitoring'). (LLM, conf=0.68)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Since not all the patients suffered from resting tremor and the resting tremor disappeared after some tremor-dominant patients took the medicine, the mean tremor prevalence was 16.9%.”
- Also stated in: § 2.4. Feature Extraction. · plain
“Since not all the patients suffered from resting tremor and the tremor may disappear after some tremor-dominant patients took the medicine, the samples of resting tremor only accounted for 16.9%.”
§ Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data > 2.1. Data Acquisition.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § 2.4. Feature Extraction. · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“rough the Kruskal-Wallis test and the Mann-Whitney U test, the TTR had a strong correlation with the subscore of resting tremor in Unified Parkinson Disease Rating Scale (UPDRS).”
§ Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data > Abstract
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
30 more claims
Create a free account to see all 71 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 25
- Probably not a substantial claim. 17
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data > 2.4. Feature Extraction.
“e ratio of the power in the range of 0.4 Hz around the DF to the total power was named as spectrum concentration (SC) and can be calculated as follows:”
§ Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data > 5. Conclusions
“| Spectrum concentration | SE | e characteristic of spectrum distribution, describing how frequency component concentrated around dominant frequency.”
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
SMOTE synthetic minority over-sampling technique
Chawla, N. V., Bowyer, K. W., Hall, L. O., & Kegelmeyer, W. P. (2002) · Journal of Artificial Intelligence Research · doi:10.1613/jair.953 · Cited by 32,865
Nearest neighbor pattern classification
Cover, T., & Hart, P. (1967) · IEEE Transactions on Information Theory · doi:10.1109/tit.1967.1053964 · Cited by 16,936
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
Use of Ranks in One-Criterion Variance Analysis
Kruskal, W. H., & Wallis, W. A. (1952) · Journal of the American Statistical Association · doi:10.1080/01621459.1952.10483441 · Cited by 13,912
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_16 · Cited by 2,915
Dorsey, E. R., Elbaz, A., Nichols, E., Abbasi, N., Abd-Allah, F., Abdelalim, A., Adsuar, J. C., Ansha, M. G., Brayne, C., Choi, J.-Y. J., et al. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30295-3 · Cited by 2,816
A brief introduction to boosting
Schapire, R. E. (1999) · International Joint Conference on Artificial Intelligence · Cited by 1,572
Cited by
Upper limb intention tremor assessment: opportunities and challenges in wearable technology
Paredes-Acuña, N., Utpadel-Fischler, D., Ding, K., Thakor, N. V., & Cheng, G. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01302-9 · Cited by 27
Operation mode selection of NIMBY facility Public Private Partnership projects
Zhao, H., Zhang, J., & Ge, Y. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254046 · Cited by 9
Kwon, D.-Y., Kwon, Y.-R., Ko, J., & Kim, J.-W. (2023) · Technology and Health Care · doi:10.3233/thc-236045 · Cited by 8
“5 Hz was used to remove low-frequency drift and high-frequency noise [26].”
MethodReddy, C. H., & Kanchana, M. (2022) · IEEE International Conference on Cybernetics, Cognition and Machine Learning Applications (ICCCMLA) · doi:10.1109/icccmla56841.2022.9988755 · Cited by 3
“H. Yuan et al. [28] investigated an effective indication for tremor quantification and created a prediction strategy for resting tremors monitored for long-term.”
BackgroundSabari, M. N., & Ch, D. (2025) · Systems Science & Control Engineering · doi:10.1080/21642583.2025.2479528 · Cited by 7
“Nonethe-less, each of these approaches presents its own array of obstacles (Yuan et al., 2021).”
Metadata
- Authors
- Yuan, H., Liu, S., Liu, J., Lin, H., Yang, C., Cai, X., Zeng, L., & Li, S.
- Affiliations
- Fudan University (CN)
- Shenzhen University (CN)
- Lifetech Scientific (China) (CN)
- Corresponding author
- Yang, Cuiwei
- Cai, Xiaodong
- Venue
- Mathematical Problems in Engineering
- Publisher
- Wiley
- Published
- 2021-10-11
- Volume
- 2021
- Pages
- 1-12
- ISSN
- 1024-123X (ISSN-L)
- 1563-5147
- OpenAlex
- W3205582452
- Cited by
- 10
- References
- 51
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 2 · 2022: 1 · 2021: 1
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Mathematical Problems in Engineering (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Natural Science Foundation of China (61071004, GYQJ-2020-1-31, 2017SHZDZX01, 15DZ2251700, JCYJ20180228162928828, 2019A1515111106)
- Shanghai Municipal Special Project of Industry Transformation and Upgrading (61071004, GYQJ-2020-1-31, 2017SHZDZX01, 15DZ2251700, JCYJ20180228162928828, 2019A1515111106)
- Shanghai Municipal Science and Technology Major Project (61071004, GYQJ-2020-1-31, 2017SHZDZX01, 15DZ2251700, JCYJ20180228162928828, 2019A1515111106)
- The Project of Shanghai Engineering Research Center (61071004, GYQJ-2020-1-31, 2017SHZDZX01, 15DZ2251700, JCYJ20180228162928828, 2019A1515111106)
- The Basic Research Projects (Subject Arrangement) of the Shenzhen Science and Technology Program (61071004, GYQJ-2020-1-31, 2017SHZDZX01, 15DZ2251700, JCYJ20180228162928828, 2019A1515111106)
- The Guangdong Basic and Applied Basic Research Foundation (61071004, GYQJ-2020-1-31, 2017SHZDZX01, 15DZ2251700, JCYJ20180228162928828, 2019A1515111106)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- resting tremor, Parkinson's disease, long-term monitoring, accelerometer data, tremor detection, tremor quantification, sample entropy, SMOTE, random forest, Unified Parkinson's Disease Rating Scale, wearable sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data. https://app.cochat.ai/papers/10.1155/2021/5669932
- The paper
- Yuan, H., Liu, S., Liu, J., Lin, H., Yang, C., Cai, X., Zeng, L., & Li, S. (2021). Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data. Mathematical Problems in Engineering. https://doi.org/10.1155/2021/5669932
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.