Assessment of Tremor Activity in the Parkinson’s Disease Using a Set of Wearable Sensors
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Tremor is the most common motor disorder of Parkinson's disease (PD) and consequently its detection plays a crucial role in the management and treatment of PD patients. The current diagnosis procedure is based on subject-dependent clinical assessment, which has a difficulty in capturing subtle tremor features. In this paper, an automated method for both resting and action/postural tremor assessment is proposed using a set of accelerometers mounted on different patient's body segments. The estimation of tremor type (resting/action postural) and severity is based on features extracted from the acquired signals and hidden Markov models. The method is evaluated using data collected from 23 subjects (18 PD patients and 5 control subjects). The obtained results verified that the proposed method successfully: 1) quantifies tremor severity with 87 % accuracy, 2) discriminates resting from postural tremor, and 3) discriminates tremor from other Parkinsonian motor symptoms during daily activities.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Related works on the characteristics of tremor have been reported, in which amplitude and frequency parameters were proved to be significantly different between the PD patients and healthy controls [33].”
From Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data (2021) · cites this paper as [33]
In the citing paper
“87% for tremors [3]”
From Wearability Assessment of a Wearable System for Parkinson’s Disease Remote Monitoring Based on a Body Area Network of Sensors (2014) · cites this paper as [3]
In the citing paper
“This system, called PERFORM, is based on a Body Area Network (BAN) of sensors which has already been validated both from the technical and clinical point for view.”
From Wearability Assessment of a Wearable System for Parkinson’s Disease Remote Monitoring Based on a Body Area Network of Sensors (2014) · cites this paper as [3]
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743
Artificial intelligence: A modern approach
Nilsson, N. J. (1996) · Artificial Intelligence · doi:10.1016/0004-3702(96)00007-0 · Cited by 10,583
Wrappers for feature subset selection
Kohavi, R., & John, G. H. (1997) · Artificial Intelligence · doi:10.1016/s0004-3702(97)00043-x · Cited by 8,947
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720 · cited 4×
“ered a difficult task even by experts [2], [11].”
InfluentialAn introduction to hidden Markov models
Rabiner, L., & Juang, B. (1986) · IEEE ASSP Magazine · doi:10.1109/massp.1986.1165342 · Cited by 4,775
The bayes net toolbox for matlab
Murphy, K. (2001) · Cited by 1,014
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623
Detection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480
Assessment of physical activity: a critical appraisal
Westerterp, K. R. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1000-2 · Cited by 459
Activity Recognition of Assembly Tasks Using Body-Worn Microphones and Accelerometers
Ward, J. A., Lukowicz, P., Troster, G., & Starner, T. E. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.197 · Cited by 431
Research works printed but not linked: 1
- zwartjes, 2010, Development of a system for measurement and analysis of tremor using a three-axis accelerometer, IEEE Trans Biomed Eng, 57, 2779
Cited by
Collection and Analysis of a Parkinson Speech Dataset With Multiple Types of Sound Recordings
Sakar, B. E., Isenkul, M. E., Sakar, C. O., Sertbas, A., Gurgen, F., Delil, S., Apaydin, H., & Kursun, O. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2245674 · Cited by 703
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 426
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
“network was able to accurately quantify the severity of the tremors with 87% accuracy, separating resting and postural tremors, and discriminating tremors from other Parkinsonian motor symptoms during daily activities [115].”
Kubota, K. J., Chen, J. A., & Little, M. A. (2016) · Movement Disorders · doi:10.1002/mds.26693 · Cited by 210
Ali, L., Zhu, C., Zhang, Z., & Liu, Y. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2940900 · Cited by 199
Metadata
- Authors
- Rigas, G., Tzallas, A. T., Tsipouras, M. G., Bougia, P., Tripoliti, E. E., Baga, D., Fotiadis, D. I., Tsouli, S. G., & Konitsiotis, S.
- Affiliations
- University of Ioannina (GR)
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-05
- Volume
- 16
- Issue
- 3
- Pages
- 478-487
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2159209410
- Cited by
- 241
- References
- 34
- Citations by year
- 2026: 5 · 2025: 13 · 2024: 17 · 2023: 19 · 2022: 22 · 2021: 27 · 2020: 18 · 2019: 35 · 2018: 17 · 2017: 12 · 2016: 19 · 2015: 9 · 2014: 15 · 2013: 11 · 2012: 2
- FWCI
- 12.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
- Keywords
- Parkinson's disease, tremor assessment, wearable sensors, accelerometer, resting tremor, postural tremor, hidden Markov models, parkinsonian motor symptoms
- MeSH terms
- Aged, Algorithms, Clothing, Humans, Markov Chains, Middle Aged, Movement, Parkinson Disease, Posture, Tremor, Case-Control Studies, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Tremor Activity in the Parkinson’s Disease Using a Set of Wearable Sensors. https://app.cochat.ai/papers/10.1109/titb.2011.2182616
- The paper
- Rigas, G., Tzallas, A. T., Tsipouras, M. G., Bougia, P., Tripoliti, E. E., Baga, D., Fotiadis, D. I., Tsouli, S. G., & Konitsiotis, S. (2012). Assessment of Tremor Activity in the Parkinson’s Disease Using a Set of Wearable Sensors. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2011.2182616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.