CoChat

Machine Learning in Detection and Classification of Leukemia Using Smear Blood Images: A Systematic Review

Open access
Ghaderzadeh, Mustafa, Asadi, Farkhondeh, Hosseini, Azamossadat, Bashash, Davood, Abolghasemi, Hassan, Roshanpour, Arash · 2021 · Scientific Programming
Cited by 176

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Introduction. The early detection and diagnosis of leukemia, i.e., the precise differentiation of malignant leukocytes with minimum costs in the early stages of the disease, is a major problem in the domain of disease diagnosis. Despite the high prevalence of leukemia, there is a shortage of flow cytometry equipment, and the methods available at laboratory diagnostic centers are time-consuming. Motivated by the capabilities of machine learning (machine learning (ML)) in disease diagnosis, the present systematic review was conducted to review the studies aiming to discover and classify leukemia by using machine learning. Methods. A systematic search in four databases (PubMed, Scopus, Web of Science, and ScienceDirect) and Google Scholar was performed via a search strategy using Machine Learning (ML), leukemia, peripheral blood smear (PBS) image, detection, diagnosis, and classification as the keywords. Initially, 116 articles were retrieved. After applying the inclusion and exclusion criteria, 16 articles remained as the population of the study. Results. This review study presents a comprehensive and systematic view of the status of all published ML-based leukemia detection and classification models that process PBS images. The average accuracy of the ML methods applied in PBS image analysis to detect leukemia was >97%, indicating that the use of ML could lead to extraordinary outcomes in leukemia detection from PBS images. Among all ML techniques, deep learning (DL) achieved higher precision and sensitivity in detecting different cases of leukemia, compared to its precedents. ML has many applications in analyzing different types of leukemia images, but the use of ML algorithms to detect acute lymphoblastic leukemia (ALL) has attracted the greatest attention in the fields of hematology and artificial intelligence. Conclusion. Using the ML method to process leukemia smear images can improve accuracy, reduce diagnosis time, and provide faster, cheaper, and safer diagnostic services. In addition to the current diagnostic methods, clinical and laboratory experts can also adopt ML methods in laboratory applications and tools.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2021/9933481

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Ghaderzadeh, M., Asadi, F., Hosseini, A., Bashash, D., Abolghasemi, H., & Roshanpour, A.
Venue
Scientific Programming
Publisher
Wiley
Published
2021-06-25
Volume
2021
Pages
1-14
ISSN
  • 1058-9244 (ISSN-L)
  • 1875-919X
OpenAlex
W3173704035
Cited by
176
References
3
FWCI
3.97
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.