Abstract
The most common technique of orthopedic surgical procedure for the correction of deformities is bone lengthening by "distraction osteogenesis," which requires periodic and ongoing bone assessment following surgery. Bone impedance is a noninvasive, quantitative method of assessing bone fracture healing. The purpose of this study was to monitor bone healing and determine when fixation devices should be removed. The left tibia of eight male New Zealand white rabbits (2.4 ± 0.4 kg) undergoing osteotomy was attached with a mini-external fixator. The bone length was increased by 1 cm one week after surgery by distracting it 1 mm per day. Before and after osteotomy, as well as every week after, bone impedance was measured in seven frequency ranges using an EVAL-AD5933EBZ board. Three orthopedic surgeons analyzed the radiographs using the Radiographic Union Scale for Tibial (RUST) score. The Kappa Fleiss coefficient was used to determine surgeon agreement, and the Spearman rank correlation coefficient was used to find out the relationship between impedance measurements and RUST scores. Finally, the device removal time was calculated by comparing the bone impedance to the preosteotomy impedance. The agreement of three orthopedic surgeons on radiographs had a Fleiss' Kappa coefficient of 49%, indicating a moderate level of agreement. The Spearman rank correlation coefficient was 0.43, indicating that impedance and radiographic techniques have a direct relationship. Impedance is expected to be used to monitor fractured or lengthened bones in a noninvasive, low-cost, portable, and straightforward manner. Furthermore, when used in conjunction with other qualitative methods such as radiography, impedance can be useful in determining the precise time of device removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures












Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148 · cited 2×
“-e Fleiss’ Kappa coefficient was used to evaluate the reliability of agreement among three surgeons [25].”
MethodImproving Bioscience Research Reporting: The ARRIVE Guidelines for Reporting Animal Research
Kilkenny, C., Browne, W. J., Cuthill, I. C., Emerson, M., & Altman, D. G. (2010) · PLoS Biology · doi:10.1371/journal.pbio.1000412 · Cited by 7,300
Improving bioscience research reporting: The ARRIVE guidelines for reporting animal research
Kilkenny, C., Browne, W. J., Cuthill, I. C., Emerson, M., & Altman, D. G. (2010) · Journal of Pharmacology and Pharmacotherapeutics · doi:10.4103/0976-500x.72351 · Cited by 6,277
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
(2008) · Springer eBooks · doi:10.1007/978-3-540-69972-9 · Cited by 1,213
Quantitative computed tomography
Adams, J. E. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.04.074 · Cited by 458 · cited 1×
“-ere are various quantitative techniques for evaluating bone fractures healing process, such as ultrasound [11], bending stiffness test [12], measurement of bone mineral density [13], quantitative computed tomography (QCT) [14], acoustic emission [15], and vibratory devices [16].”
BackgroundVariability in the Assessment of Fracture-Healing in Orthopaedic Trauma Studies
Corrales, L. A., Morshed, S., Bhandari, M., & Miclau, T. (2008) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.01580 · Cited by 415
Litrenta, J., Tornetta, P., Mehta, S., Jones, C., O'Toole, R. V., Bhandari, M., Kottmeier, S., Ostrum, R., Egol, K., Ricci, W., et al. (2015) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000000390 · Cited by 287 · cited 1×
“-e union of bone after the osteotomy is scored by RUST [19, 24].”
MethodBhandari, M., Fong, K., Sprague, S., Williams, D., & Petrisor, B. (2012) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.k.01344 · Cited by 179 · cited 1×
“Physician examinations are subjective, which might result in varying and erroneous judgments [3].”
BackgroundCurrent concepts of leg lengthening
Hasler, C. C., & Krieg, A. H. (2012) · Journal of Children s Orthopaedics · doi:10.1007/s11832-012-0391-5 · Cited by 143
Research works printed but not linked: 2
- Mijailovic N. Ranković V. Improvement of diagnostics in orthopedics using electrical impedance measurement Proceedings of the 2 Nd International Conference on Quality of Life August 2017 Penang, Malasiya p. 67
- Nishida A. Kim W. C. Yoshida T. Yamada N. Ikegaya H. Kubo T. Measurement of bone electrical impedance in cadavers Proceedings of the Annual Meeting of the Orthopaedic Research Society (ORS) October 2009 Canberra, ACT, Australia
Cited by
Methods to accelerate fracture healing – a narrative review from a clinical perspective
Ganse, B. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1384783 · Cited by 33
Mechanoresponsive regulation of tissue regeneration during distraction osteogenesis
Hu, W., Guo, Z., Tang, W., & Long, J. (2024) · The FASEB Journal · doi:10.1096/fj.202401303r · Cited by 25
“115 Indeed, the consolidation phase is the most time-consuming period, with an average estimate suggesting that 1 month is required for every 1 cm of extension.”
Sensor‐enabled Orthopedic Implants for Musculoskeletal Monitoring
Huang, J., Dong, H., Zhang, W., Cui, J., Li, Q., Wang, J., Zhao, Z., & Zang, X. (2025) · Advanced Sensor Research · doi:10.1002/adsr.202400138 · Cited by 24
Heidari, N., Vosough, M., Bagherifard, A., Sami, S. H., Sarabi, P. A., Behmanesh, A., & Shams, R. (2024) · Pathology - Research and Practice · doi:10.1016/j.prp.2024.155615 · Cited by 3
Self-citationFrost, M. W., Tirta, M., Rahbek, O., Rytoft, L. A., Ding, M. L., Shen, M., Duch, K. S., & Kold, S. (2024) · Journal of Experimental Orthopaedics · doi:10.1002/jeo2.12048 · Cited by 2
“Some studies placed the electrodes within the fracture site [13], which is clinically unsound, while others used the metal pins from the external fi xator as electrodes giving way to noise from surrounding tissues [12, 14, 21, 25 – 27].”
Metadata
- Authors
- Sadoughi, F., Behmanesh, A., Najd Mazhar, F., Joghataei, M. T., Yazdani, S., Shams, R., Morovvati, H., Najaf Asaadi, S., & Vosough, A.
- Affiliations
- Iran University of Medical Sciences (IR)
- Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
- Shahid Beheshti University of Medical Sciences (IR)
- University of Tehran (IR)
- Department of Basic Science, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
- Islamic Azad University of Garmsar (IR)
- Corresponding author
- Behmanesh, Ali
- ORCID
- Venue
- Journal of Healthcare Engineering
- Publisher
- Wiley
- Published
- 2022-04-07
- Volume
- 2022
- Pages
- 1-13
- ISSN
- 2040-2295 (ISSN-L)
- 2040-2309
- PMC
- PMC9010194
- OpenAlex
- W4226197551
- Cited by
- 10
- References
- 35
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 4 · 2022: 1
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Journal of Healthcare Engineering (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Iran University of Medical Sciences (IUMS/SHMIS-97-3-37-12579)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Keywords
- bone healing monitoring, distraction osteogenesis, bioimpedance, tibial osteotomy, external fixator, mini external fixator, rabbit model
- MeSH terms
- Animals, Humans, Male, Osteotomy, Rabbits, Tibia, External Fixators, Fracture Healing, Osteogenesis, Distraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bone Healing Monitoring in Bone Lengthening Using Bioimpedance. https://app.cochat.ai/papers/10.1155/2022/3226440
- The paper
- Sadoughi, F., Behmanesh, A., Najd Mazhar, F., Joghataei, M. T., Yazdani, S., Shams, R., Morovvati, H., Najaf Asaadi, S., & Vosough, A. (2022). Bone Healing Monitoring in Bone Lengthening Using Bioimpedance. Journal of Healthcare Engineering. https://doi.org/10.1155/2022/3226440
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.