Cited by 20Artificial Intelligence in Healthcare and EducationMedical Image Segmentation TechniquesCongenital Heart Disease Studies

Application of Artificial Intelligence in Anatomical Structure Recognition of Standard Section of Fetal Heart

Open access
Wu, Huiling, Wu, Bingzheng, Lai, Fangping, Liu, Peizhong, Lyu, Guorong, He, Shaozheng, Dai, Jiangfeng·2023·Computational and Mathematical Methods in Medicine

Abstract

Congenital heart defect (CHD) refers to the overall structural abnormality of the heart or large blood vessels in the chest cavity. It is the most common type of fetal congenital defects. Prenatal diagnosis of congenital heart disease can improve the prognosis of the fetus to a certain extent. At present, prenatal diagnosis of CHD mainly uses 2D ultrasound to directly evaluate the development and function of fetal heart and main structures in the second trimester of pregnancy. Artificial recognition of fetal heart 2D ultrasound is a highly complex and tedious task, which requires a long period of prenatal training and practical experience. Compared with manual scanning, computer automatic identification and classification can significantly save time, ensure efficiency, and improve the accuracy of diagnosis. In this paper, an effective artificial intelligence recognition model is established by combining ultrasound images with artificial intelligence technology to assist ultrasound doctors in prenatal ultrasound fetal heart standard section recognition. The method data in this paper were obtained from the Second Affiliated Hospital of Fujian Medical University. The fetal apical four-chamber heart section, three vessel catheter section, three vessel trachea section, right ventricular outflow tract section, and left ventricular outflow tract section were collected at 20-24 weeks of gestation. 2687 image data were used for model establishment, and 673 image data were used for model validation. The experiment shows that the map value of this method in identifying different anatomical structures reaches 94.30%, the average accuracy rate reaches 94.60%, the average recall rate reaches 91.0%, and the average F1 coefficient reaches 93.40%. The experimental results show that this method can effectively identify the anatomical structures of different fetal heart sections and judge the standard sections according to these anatomical structures, which can provide an auxiliary diagnostic basis for ultrasound doctors to scan and lay a solid foundation for the diagnosis of congenital heart disease.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2023/5650378

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Advantages of AI in fetal echocardiography include facilitation of standard view acquisition and CHD detection, and significant reduction in examination time.

    “Advantages are the facilitation of standard view acquisition [58,60] and CHD detection [53,61,62], as well as a significant reduction in examination time [52,55].”

    From Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology (2023) · cites this paper as [58]

    The Discussion (section 4.4; page unavailable) says the model identifies standard fetal-heart views faster and could help doctors obtain them. The Conclusion (section 5; page unavailable) describes potential assistance with CHD screening, and the Abstract says automatic identification can save time compared with manual scanning. The paper does not report a measured, statistically significant reduction in examination time or demonstrate improved CHD detection. (LLM, conf=0.84)

    Experimental — accuracy not yet measured
  • Recognition of small CHD or small anatomical structures such as the trachea was limited in some models.

    “Lastly, the recognition of small CHD or small anatomical structures such as the trachea was limited in some models [55,58].”

    From Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology (2023) · cites this paper as [58]

    The Test Results section reports that trachea recognition was the weakest among the anatomical structures tested, and the Discussion says its recognition effect was relatively poor. The paper also discusses differences between models in recognizing small anatomical targets. It does not report model recognition results for small congenital heart defects, so that part of the claim is unsupported. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 22 · Cited by 20

Research works printed but not linked: 3

  1. [3]Guorong L. Ultrasound Diagnosis of Fetal Brain and Cardiac Malformations 2010 Peking University Medical Press
  2. [9]Yuhuan H. Wendi T. Xin L. Yueqing W. Yu Y. Design and implementation of the standard section navigation visualization system for transesophageal echocardiographycomputer application Chinese Journal of Computer Application 2015 35 212-215 p. 241
  3. [25]Yan J. Yan X. Yang J. Analysis of the clinical significance and the risk factors of prenatal ultrasound screening for fetal congenital heart disease Chinese Journal of General Practice 2016 14 1 114 115

Authors
Wu, H., Wu, B., Lai, F., Liu, P., Lyu, G., He, S., & Dai, J.
Affiliations
  • Second Affiliated Hospital of Fujian Medical University (CN)
  • Huaqiao University (CN)
Corresponding author
  • Lyu, Guorong
  • He, Shaozheng
Venue
Computational and Mathematical Methods in Medicine
Publisher
Wiley
Published
2023-01
Volume
2023
Issue
1
Pages
5650378-5650378
ISSN
  • 1748-670X (ISSN-L)
  • 1748-6718
OpenAlex
W4317840203
Cited by
20
References
22
Citations by year
2026: 2 · 2025: 8 · 2024: 5 · 2023: 5
FWCI
0.80
Type
journal article
Language
en
Open access
Locations
  • Computational and Mathematical Methods in Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
Natural Science Foundation of Fujian Province (2021J01275, 2020J0112)
Topics
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Medicine › Epidemiology › Congenital Heart Disease Studies
Keywords
fetal heart, congenital heart disease, prenatal diagnosis, prenatal ultrasound, anatomical structure recognition, computer-aided diagnosis, apical four-chamber view, right ventricular outflow tract, left ventricular outflow tract, second trimester
MeSH terms
Artificial Intelligence, Echocardiography, Female, Fetal Heart, Heart Defects, Congenital, Humans, Pregnancy, Ultrasonography, Prenatal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review