Automated enzymatic determination of plasma free fatty acids by centrifugal analysis
Open accessThe DOI matches its Crossref record.
Abstract
Recently, alternative assays for FFA, based on specific enzymic oxidation by acyl-coenzyme-A-synthetase (ACS) and acyl-coenzyme-A-oxidase (ACOD),have been developed (Shimizu et al. [2]).Hydrogen peroxide generated by these reactions can be quantitated colorimetrically (Mizuno et al. [3]; Shimizu et al. [4]; Matsubara et al. [5]) and is directly related to the FFA content of the test sample.One such procedure involving specific peroxidase (POD)-dependent quinone-dye formation is now available commercially.This article reports on the adaptation of the method .forroutine automated determination of FFA using an I.L. Multistat III microcentrifugal analyser. Materials and methods Reagents and instrumentationWako (Wako Pure Chemical Industries Ltd, Japan) NEFA C-Test (ACS-ACOD method) kits code No. 273-75409 were supplied by Alpha Laboratories, Eastleigh, Hampshire, UK.A Cecil CE 595 double-beam spectrophotometer (Cecil Instruments Ltd, Cambridge, UK) was used for all manual determinations.Automated analyses were performed using an I.L. Multistat III fluorescence/light scattering microcentri- fugal analyser (MCA) (Instrumentation Laboratory [UK] Ltd, Warrington, Cheshire).A solution of 152.3 mg oleic acid (Sigma Chemicals, Poole, Dorset, UK) in 100 ml 0" 1 Triton X-100 (5 mmol oleic acid per litre) acted as a stock standard. SamplesOvine and bovine whole-blood samples were collected in 10 ml Vacutainers (Becton-Dickinson [UK] Ltd, London) containing heparin (0.1-0.2mg/ml blood), oxalate/fluoride (1.25 and 1.0 mg/ml blood respectively), EDTA (1 mg/ml) or no anticoagu- lant.Plasma or serum were removed following centrifugation at 5000 g for 10 min at 4C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ho, K. Y., Veldhuis, J. D., Johnson, M. L., Furlanetto, R., Evans, W. S., Alberti, K. G., & Thorner, M. O. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113450 · Cited by 503
“SmC, unesterified fatty acids, acetoacetate, and ,#-hydroxbutyrate concentrations were measured using methods as previously described (16, 17) and as adapted from reference 18.”
Method(1992) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.74.4.757 · Cited by 296
Correction of acidosis in humans with CRF decreases protein degradation and amino acid oxidation
Reaich, D., Channon, S. M., Scrimgeour, C. M., Daley, S. E., Wilkinson, R., & Goodship, T. H. (1993) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1993.265.2.e230 · Cited by 213
Effects of growth hormone on insulin sensitivity and forearm metabolism in normal man
M�ller, N., Butler, P. C., Antsiferov, M. A., & Alberti, K. G. M. M. (1989) · Diabetologia · doi:10.1007/bf00505182 · Cited by 192
Hartman, M. L., Clayton, P. E., Johnson, M. L., Celniker, A., Perlman, A. J., Alberti, K. G., & Thorner, M. O. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116480 · Cited by 192
Metadata
- Authors
- Knox, D. P., & Jones, D. G.
- Venue
- Journal of Analytical Methods in Chemistry
- Publisher
- Wiley
- Published
- 1984-01
- Volume
- 6
- Issue
- 3
- Pages
- 152-154
- ISSN
- 2090-8865 (ISSN-L)
- 2090-8873
- OpenAlex
- W2039190793
- Cited by
- 58
- References
- 0
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated enzymatic determination of plasma free fatty acids by centrifugal analysis. https://app.cochat.ai/papers/10.1155/s1463924684000286
- The paper
- Knox, D. P., & Jones, D. G. (1984). Automated enzymatic determination of plasma free fatty acids by centrifugal analysis. Journal of Analytical Methods in Chemistry. https://doi.org/10.1155/s1463924684000286
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.