A Novel Technology for the Imaging of Acidic Prostate Tumors by Positron Emission Tomography
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Solid tumors often develop an acidic environment due to the Warburg effect. The effectiveness of diagnosis and therapy may therefore be enhanced by the design and use of pH-sensitive agents that target acidic tumors. Recently, a novel technology was introduced to target acidic tumors using pH low insertion peptide (pHLIP), a peptide that inserts across cell membranes as an α-helix when the extracellular pH (pHe) is acidic. In this study, we expanded the application of the pHLIP technology to include positron emission tomography imaging of the acidic environment in prostate tumors using 64Cu conjugated to the pHLIP (64Cu-DOTA-pHLIP). Studies showed that this construct avidly accumulated in LNCaP and PC-3 tumors, with higher uptake and retention in the LNCaP tumors. Uptake correlated with differences in the bulk pHe of PC-3 and LNCaP tumors measured in magnetic resonance spectroscopy experiments by the 31P chemical shift of the pHe marker 3-aminopropylphosphonate. This article introduces a novel class of noninvasive pH-selective positron emission tomography imaging agents and opens new research directions in the diagnosis of acidic solid tumors. [Cancer Res 2009;69(10):4510–6]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic resonance imaging of pH in vivo using hyperpolarized 13C-labelled bicarbonate
Gallagher, F. A., Kettunen, M. I., Day, S. E., Hu, D.-E., Ardenkjær-Larsen, J. H., Zandt, R. I. ‘., Jensen, P. R., Karlsson, M., Golman, K., Lerche, M. H., et al. (2008) · Nature · doi:10.1038/nature07017 · Cited by 849 · cited 1×
“These approaches include the use of T1-weighted magnetic resonance imaging with extracellular contrast agents that exhibit pH-dependent (1)H relaxation enhancement (13), (1)H and (31)P pHdependent chemical shift measurements of exogenous extracellular species (14–16), and (13)C chemical shift imaging of hyperpolarized…”
BackgroundRofstad, E. K., Mathiesen, B., Kindem, K., & Galappathi, K. (2006) · Cancer Research · doi:10.1158/0008-5472.can-06-0983 · Cited by 668
MRI of the tumor microenvironment
Gillies, R. J., Raghunand, N., Karczmar, G. S., & Bhujwalla, Z. M. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10181 · Cited by 550 · cited 1×
“aminopropylphosphonate (3-APP) have confirmed that the average pHe of tumors is acidic, with values reaching as low as 6.0 ( 18 ).”
BackgroundInfluentialEfficient production of high specific activity 64Cu using a biomedical cyclotron
McCarthy, D. W., Shefer, R. E., Klinkowstein, R. E., Bass, L. A., Margeneau, W. H., Cutler, C. S., Anderson, C. J., & Welch, M. J. (1997) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(96)00157-6 · Cited by 533 · cited 1×
“processed by previously reported literature methods (28).”
Boswell, C. A., Sun, X., Niu, W., Weisman, G. R., Wong, E. H., Rheingold, A. L., & Anderson, C. J. (2004) · Journal of Medicinal Chemistry · doi:10.1021/jm030383m · Cited by 483 · cited 1×
“(64)Cu has been shown to dissociate in vivo from DOTA and DOTA-conjugates, undergoing subsequent metabolism and trans-chelation to superoxide dismutase and other proteins, resulting in increased accumulation in the blood and liver (27, 34, 35).”
BackgroundCopper radionuclides and radiopharmaceuticals in nuclear medicine
Blower, P. J., Lewis, J. S., & Zweit, J. (1996) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(96)00130-8 · Cited by 406 · cited 1×
“Positron emission tomography (PET) is a widely used molecular imaging modality in both clinical and research settings (19).”
MethodSelf-citation(2005) · PubMed · Cited by 395
Cairns, R., Papandreou, I., & Denko, N. (2006) · Molecular Cancer Research · doi:10.1158/1541-7786.mcr-06-0002 · Cited by 370 · cited 1×
“, hypoxia and acidity), which are present in 90% of tumor microenvironments, are considered promising environmental markers for tumor targeting (2, 3).”
BackgroundTumor pH controls the in vivo efficacy of weak acid and base chemotherapeutics
Gerweck, L. E., Vijayappa, S., & Kozin, S. (2006) · Molecular Cancer Therapeutics · doi:10.1158/1535-7163.mct-06-0024 · Cited by 362 · cited 7×
“www.aacrjournals.org 4515 Cancer Res 2009;69: ( 10 ).”
BackgroundMethodInfluential31P-MRS measurements of extracellular pH of tumors using 3-aminopropylphosphonate
Gillies, R. J., Liu, Z., & Bhujwalla, Z. (1994) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1994.267.1.c195 · Cited by 351 · cited 2×
“The resulting estimated chemical-shift difference between 3-APP and the pH-independent α-nucleoside triphosphate (α-NTP) resonance (33) was used to determine extracellular pH based on the fitting parameters provided by Gillies, et al (31).”
Method
Cited by
Zhang, X., Lin, Y., & Gillies, R. J. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.068981 · Cited by 659
Stimuli-responsive nanoparticles for targeting the tumor microenvironment
Du, J., Lane, L. A., & Nie, S. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.08.050 · Cited by 382
Acidic tumor microenvironment and pH-sensing G protein-coupled receptors
Justus, C. R., Dong, L., & Yang, L. V. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00354 · Cited by 374
Probe for the measurement of cell surface pH in vivo and ex vivo
Anderson, M., Moshnikova, A., Engelman, D. M., Reshetnyak, Y. K., & Andreev, O. A. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608247113 · Cited by 217
“…enhances peptide hydrophobicity and promotes membrane-associated folding and insertion of a transmembrane helix (28, 29). pHLIPs labeled with optical, PET or single-photon emission computed tomography probes target acidic diseased tissue and are considered to be novel acidity markers (30 – 37).”
Self-citationFamily of pH (low) insertion peptides for tumor targeting
Weerakkody, D., Moshnikova, A., Thakur, M. S., Moshnikova, V., Daniels, J., Engelman, D. M., Andreev, O. A., & Reshetnyak, Y. K. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1303708110 · Cited by 208
Self-citationZeglis, B. M., & Lewis, J. S. (2011) · Dalton Transactions · doi:10.1039/c0dt01595d · Cited by 198
Self-citationEvaluations of extracellular pH within in vivo tumors using acidoCEST MRI
Chen, L. Q., Howison, C. M., Jeffery, J. J., Robey, I. F., Kuo, P. H., & Pagel, M. D. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25053 · Cited by 193
“Positron emission tomography (20,21), electron paramagnetic resonance spectroscopy (22), and MR spectroscopy (23,24) can measure tumor pHe, but these methods are inaccurate, insensitive, or difficult to implement especially for clinical diagnoses.”
BackgroundPeppicelli, S., Bianchini, F., & Calorini, L. (2014) · Cancer and Metastasis Reviews · doi:10.1007/s10555-014-9506-4 · Cited by 192
“investigate the acidic environment in prostate tumors using 64Cu-conjugated pHLIP (64Cu-DOTA-pHLIP) [110].”
BackgroundThe impact of tumour pH on cancer progression: strategies for clinical intervention
Ward, C., Meehan, J., Gray, M. E., Murray, A. F., Argyle, D. J., Kunkler, I. H., & Langdon, S. P. (2020) · Exploration of Targeted Anti-tumor Therapy · doi:10.37349/etat.2020.00005 · Cited by 179
An, M., Wijesinghe, D., Andreev, O. A., Reshetnyak, Y. K., & Engelman, D. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014403107 · Cited by 165
“5, AlexaFluor 750) or to the positron emission tomography probe (64)Cu-1;4;7;10-tetra-aza-cylcododecane-N;N 0;N 00;N 000-tetra-acetic acid, these pHLIP imaging constructs successfully targeted acidic tissues in vivo, including tumors, kidneys, and sites of inflammation (21, 23).”
BackgroundSelf-citationImaging tumor acidosis: a survey of the available techniques for mapping in vivo tumor pH
Anemone, A., Consolino, L., Arena, F., Capozza, M., & Longo, D. L. (2019) · Cancer and Metastasis Reviews · doi:10.1007/s10555-019-09782-9 · Cited by 162
“In a preliminary study, (64)Cu-DOTA-pHLIP was successfully imaged in prostate tumors (LNCaP and PC-3) showing a higher uptake and retention in the LNCaP tumors, whereas the uptake was reduced in mice that received 7 days of bicarbonated water [131].”
pH-sensitive drug-delivery Systems for Tumor Targeting
He, X., Li, J., An, S., & Jiang, C. (2013) · Therapeutic Delivery · doi:10.4155/tde.13.120 · Cited by 159
Ramamonjisoa, N., & Ackerstaff, E. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00003 · Cited by 93
Metadata
- Authors
- Vāvere, A. L., Biddlecombe, G. B., Spees, W. M., Garbow, J. R., Wijesinghe, D., Andreev, O. A., Engelman, D. M., Reshetnyak, Y. K., & Lewis, J. S.
- Venue
- Cancer Research
- Published
- 2009-05-15
- Volume
- 69
- Issue
- 10
- Pages
- 4510-4516
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2085319321
- Cited by
- 185
- References
- 33
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.