Determination of Tumor Margins with Surgical Specimen Mapping Using Near-Infrared Fluorescence
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
For many solid tumors, surgical resection remains the gold standard and tumor-involved margins are associated with poor clinical outcomes. Near-infrared (NIR) fluorescence imaging using molecular agents has shown promise for in situ imaging during resection. However, for cancers with difficult imaging conditions, surgical value may lie in tumor mapping of surgical specimens. We thus evaluated a novel approach for real-time, intraoperative tumor margin assessment. Twenty-one adult patients with biopsy-confirmed squamous cell carcinoma arising from the head and neck (HNSCC) scheduled for standard-of-care surgery were enrolled. Cohort 1 (n = 3) received panitumumab-IRDye800CW at an intravenous microdose of 0.06 mg/kg, cohort 2A (n = 5) received 0.5 mg/kg, cohort 2B (n = 7) received 1 mg/kg, and cohort 3 (n = 6) received 50 mg. Patients were followed 30 days postinfusion and adverse events were recorded. Imaging was performed using several closed- and wide-field devices. Fluorescence was histologically correlated to determine sensitivity and specificity. In situ imaging demonstrated tumor-to-background ratio (TBR) of 2 to 3, compared with ex vivo specimen imaging TBR of 5 to 6. We obtained clear differentiation between tumor and normal tissue, with a 3-fold signal difference between positive and negative specimens (P < 0.05). We achieved high correlation of fluorescence intensity with tumor location with sensitivities and specificities >89%; fluorescence predicted distance of tumor tissue to the cut surface of the specimen. This novel method of detecting tumor-involved margins in surgical specimens using a cancer-specific agent provides highly sensitive and specific, real-time, intraoperative surgical navigation in resections with complex anatomy, which are otherwise less amenable to image guidance. Significance: This study demonstrates that fluorescence can be used as a sensitive and specific method of guiding surgeries for head and neck cancers and potentially other cancers with challenging imaging conditions, increasing the probability of complete resections and improving oncologic outcomes. Cancer Res; 78(17); 5144–54. ©2018 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A pathology atlas of the human cancer transcriptome
Uhlen, M., Zhang, C., Lee, S., Sjöstedt, E., Fagerberg, L., Bidkhori, G., Benfeitas, R., Arif, M., Liu, Z., Edfors, F., et al. (2017) · Science · doi:10.1126/science.aan2507 · Cited by 3,371
Wild-Type KRAS Is Required for Panitumumab Efficacy in Patients With Metastatic Colorectal Cancer
Amado, R. G., Wolf, M., Peeters, M., Van Cutsem, E., Siena, S., Freeman, D. J., Juan, T., Sikorski, R., Suggs, S., Radinsky, R., et al. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.7116 · Cited by 3,207 · cited 3×
“Panitumumab is a fully humanizedmonoclonal IgG2 antibody that binds to the extracellular domain of EGFR with high affinity, and it was first FDA approved in 2006 for metastatic colorectal cancer (15, 16).”
BackgroundEpidermal growth factor-related peptides and their receptors in human malignancies
Salomon, D. S., Brandt, R., Ciardiello, F., & Normanno, N. (1995) · Critical Reviews in Oncology/Hematology · doi:10.1016/1040-8428(94)00144-i · Cited by 2,690
EGF–ERBB signalling: towards the systems level
Citri, A., & Yarden, Y. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1962 · Cited by 2,004 · cited 1×
“Fluorescence signal was shown to be relatively homogeneous across the cytoplasm and cellular membrane of tumor tissue, consistent with the known antibody–receptor complex transition from the cell surface to the cytoplasm (24).”
Backgroundvan Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545 · cited 1×
“IRDye800CW-NHS (IRDye800CW-N-hydroxysuccinimide ester; LI-COR Biosciences) was used as a fluorescent probe with a NIR absorption and emission peak of 778 nm/794 nm as discussed previously (17, 20, 21).”
MethodGrandis, J. R., & Tweardy, D. J. (1993) · PubMed · Cited by 851
Safety and Tumor Specificity of Cetuximab-IRDye800 for Surgical Navigation in Head and Neck Cancer
Rosenthal, E. L., Warram, J. M., de Boer, E., Chung, T. K., Korb, M. L., Brandwein-Gensler, M., Strong, T. V., Schmalbach, C. E., Morlandt, A. B., Agarwal, G., et al. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-3284 · Cited by 469 · cited 1×
“This shows improved safety over cetuximab-IRDye800CW, a compound we previously used to demonstrate simple, initial feasibility and safety of a fluorescently labeled anti-EGFR antibody (10).”
BackgroundSelf-citationDevelopment of ABX-EGF, a fully human anti-EGF receptor monoclonal antibody, for cancer therapy
Yang, X. (2001) · Critical Reviews in Oncology/Hematology · doi:10.1016/s1040-8428(00)00134-7 · Cited by 463 · cited 2×
“Previous research on another anti-EGFR antibody, cetuximab-IRDye800CW, demonstrated promising results, and, due to the higher binding affinity and improved safety profile of panitumumab, we chose panitumumabIRDye800CW to evaluate a new, innovative method of utilizing fluorescence for tumor discrimination and tumor map…”
BackgroundMethodBurggraaf, J., Kamerling, I. M. C., Gordon, P. B., Schrier, L., de Kam, M. L., Kales, A. J., Bendiksen, R., Indrevoll, B., Bjerke, R. M., Moestue, S. A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3641 · Cited by 299
Lamberts, L. E., Koch, M., de Jong, J. S., Adams, A. L. L., Glatz, J., Kranendonk, M. E. G., Terwisscha van Scheltinga, A. G. T., Jansen, L., de Vries, J., Lub-de Hooge, M. N., et al. (2017) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-16-0437 · Cited by 285
Hoogstins, C. E. S., Tummers, Q. R. J. G., Gaarenstroom, K. N., de Kroon, C. D., Trimbos, J. B. M. Z., Bosse, T., Smit, V. T. H. B. M., Vuyk, J., van de Velde, C. J. H., Cohen, A. F., et al. (2016) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-15-2640 · Cited by 271
St John, E. R., Al-Khudairi, R., Ashrafian, H., Athanasiou, T., Takats, Z., Hadjiminas, D. J., Darzi, A., & Leff, D. R. (2017) · Annals of Surgery · doi:10.1097/sla.0000000000001897 · Cited by 251
Jakobovits, A., Amado, R. G., Yang, X., Roskos, L., & Schwab, G. (2007) · Nature Biotechnology · doi:10.1038/nbt1337 · Cited by 230 · cited 2×
“Panitumumab is a fully humanizedmonoclonal IgG2 antibody that binds to the extracellular domain of EGFR with high affinity, and it was first FDA approved in 2006 for metastatic colorectal cancer (15, 16).”
BackgroundTerwisscha van Scheltinga, A. G. T., van Dam, G. M., Nagengast, W. B., Ntziachristos, V., Hollema, H., Herek, J. L., Schröder, C. P., Kosterink, J. G. W., Lub-de Hoog, M. N., & de Vries, E. G. E. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092833 · Cited by 202
Day, K. E., Sweeny, L., Kulbersh, B. D., Zinn, K. R., & Rosenthal, E. L. (2013) · Molecular Imaging and Biology · doi:10.1007/s11307-013-0652-9 · Cited by 113 · cited 1×
“Imaging contrast between tumor andnormal tissuewas consistent with preclinical data (25).”
BackgroundSelf-citationGrootendorst, M. R., Cariati, M., Pinder, S. E., Kothari, A. S., Douek, M., Kovács, T., Hamed, H., Pawa, A., Nimmo, F., Owen, J., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.181032 · Cited by 112
Mesoscopic and Macroscopic Optoacoustic Imaging of Cancer
Taruttis, A., van Dam, G. M., & Ntziachristos, V. (2015) · Cancer Research · doi:10.1158/0008-5472.can-14-2522 · Cited by 110
McNally, L. R., Mezera, M., Morgan, D. E., Frederick, P. J., Yang, E. S.-H., Eltoum, I.-E. A., & Grizzle, W. E. (2016) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-16-0573 · Cited by 106
Moore, L. S., Rosenthal, E. L., Chung, T. K., de Boer, E., Patel, N., Prince, A. C., Korb, M. L., Walsh, E. M., Young, E. S., Stevens, T. M., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.171413 · Cited by 50
Self-citationBhattacharyya, S., Patel, N. L., Wei, L., Riffle, L. A., Kalen, J. D., Hill, G. C., Jacobs, P. M., Zinn, K. R., & Rosenthal, E. L. (2014) · MedChemComm · doi:10.1039/c4md00116h · Cited by 49 · cited 1×
“IRDye800CW-NHS (IRDye800CW-N-hydroxysuccinimide ester; LI-COR Biosciences) was used as a fluorescent probe with a NIR absorption and emission peak of 778 nm/794 nm as discussed previously (17, 20, 21).”
MethodSelf-citationMoore, L. S., Rosenthal, E. L., de Boer, E., Prince, A. C., Patel, N., Richman, J. M., Morlandt, A. B., Carroll, W. R., Zinn, K. R., & Warram, J. M. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-1022-1 · Cited by 48
Self-citationThreshold Analysis and Biodistribution of Fluorescently Labeled Bevacizumab in Human Breast Cancer
Koch, M., de Jong, J. S., Glatz, J., Symvoulidis, P., Lamberts, L. E., Adams, A. L. L., Kranendonk, M. E. G., van Scheltinga, A. G. T. T., Aichler, M., Jansen, L., et al. (2016) · Cancer Research · doi:10.1158/0008-5472.can-16-1773 · Cited by 41
Cited by
Latest developments in molecular tracers for fluorescence image-guided cancer surgery
Hernot, S., van Manen, L., Debie, P., Mieog, J. S. D., & Vahrmeijer, A. L. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30317-1 · Cited by 471
Real-time fluorescence imaging in intraoperative decision making for cancer surgery
Lauwerends, L. J., van Driel, P. B. A. A., Baatenburg de Jong, R. J., Hardillo, J. A. U., Koljenovic, S., Puppels, G., Mezzanotte, L., Löwik, C. W. G. M., Rosenthal, E. L., Vahrmeijer, A. L., et al. (2021) · The Lancet Oncology · doi:10.1016/s1470-2045(20)30600-8 · Cited by 276
Self-citationFluorescence image-guided tumour surgery
Wang, K., Du, Y., Zhang, Z., He, K., Cheng, Z., Yin, L., Dong, D., Li, C., Li, W., Hu, Z., et al. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00017-1 · Cited by 239
Voskuil, F. J., Steinkamp, P. J., Zhao, T., van der Vegt, B., Koller, M., Doff, J. J., Jayalakshmi, Y., Hartung, J. P., Gao, J., Sumer, B. D., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16814-4 · Cited by 180
Activatable fluorescent probes for real-time imaging-guided tumor therapy
Duan, Q.-J., Zhao, Z.-Y., Zhang, Y.-J., Fu, L., Yuan, Y.-Y., Du, J.-Z., & Wang, J. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114793 · Cited by 166
Metadata
- Authors
- Gao, R. W., Teraphongphom, N. T., van den Berg, N. S., Martin, B. A., Oberhelman, N. J., Divi, V., Kaplan, M. J., Hong, S. S., Lu, G., Ertsey, R., Tummers, W. S. F. J., Gomez, A. J., Holsinger, F. C., Kong, C. S., Colevas, A. D., Warram, J. M., & Rosenthal, E. L.
- Venue
- Cancer Research
- Published
- 2018-09-01
- Volume
- 78
- Issue
- 17
- Pages
- 5144-5154
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2810142842
- Cited by
- 218
- References
- 22
- FWCI
- 16.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.