Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Single-Dose and Multiple-Dose Administration of Indole-3-Carbinol to Women: Pharmacokinetics Based on 3,3′-Diindolylmethane

Reed, Gregory A., Arneson, Dora W., Putnam, William C., Smith, Holly J., Gray, John C., Sullivan, Debra K., Mayo, Matthew S., Crowell, James A., Hurwitz, Aryeh · 2006 · Cancer Epidemiology, Biomarkers & Prevention

Abstract

We have completed a phase I trial in women of the proposed chemopreventive natural product indole-3-carbinol (I3C). Women received oral doses of 400, 600, 800, 1,000, and 1,200 mg I3C. Serial plasma samples were analyzed by high-performance liquid chromatography-mass spectrometry for I3C and several of its condensation products. I3C itself was not detectable in plasma. The only detectable I3C-derived product was 3,3′-diindolylmethane (DIM). Mean Cmax for DIM increased from 61 ng/mL at the 400-mg I3C dose to 607 ng/mL following a 1,000-mg dose. No further increase was observed following a 1,200-mg dose. A similar result was obtained for the area under the curve, which increased from 329 h ng/mL at the 400-mg dose to 3,376 h ng/mL after a 1,000-mg dose of I3C. Significant interindividual quantitative variation was seen in plasma DIM values within each dosing group, but the overall profiles were qualitatively similar, with no quantifiable DIM before dosing, tmax at ∼2 h, and DIM levels near or below 15 ng/mL (the limit of quantitation), by 24 h. Different results were obtained for 14 subjects who received a 400-mg dose of I3C after 8 weeks of twice-daily I3C dosing. Although the predose sampling occurred at least 12 h after the last known ingestion of I3C, 6 of 14 subjects exhibited Cmax for DIM in their predose plasma. Despite this high initial value, plasma DIM for all subjects decreased to near or below the limit of quantitation within the 12-h sampling period. Possible reasons for this disparity between apparent t1/2 of DIM and the high predose values are discussed. (Cancer Epidemiol Biomarkers Prev 2006;15(12):2477–81)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1158/1055-9965.epi-06-0396

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 168

Metadata

Authors
Reed, G. A., Arneson, D. W., Putnam, W. C., Smith, H. J., Gray, J. C., Sullivan, D. K., Mayo, M. S., Crowell, J. A., & Hurwitz, A.
Venue
Cancer Epidemiology, Biomarkers & Prevention
Published
2006-12-01
Volume
15
Issue
12
Pages
2477-2481
ISSN
  • 1055-9965 (ISSN-L)
  • 1538-7755
OpenAlex
W2100269181
Cited by
168
References
1
FWCI
6.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single-Dose and Multiple-Dose Administration of Indole-3-Carbinol to Women: Pharmacokinetics Based on 3,3′-Diindolylmethane. https://app.cochat.ai/papers/10.1158/1055-9965.epi-06-0396
The paper
Reed, G. A., Arneson, D. W., Putnam, W. C., Smith, H. J., Gray, J. C., Sullivan, D. K., Mayo, M. S., Crowell, J. A., & Hurwitz, A. (2006). Single-Dose and Multiple-Dose Administration of Indole-3-Carbinol to Women: Pharmacokinetics Based on 3,3′-Diindolylmethane. Cancer Epidemiology, Biomarkers & Prevention. https://doi.org/10.1158/1055-9965.epi-06-0396

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.