Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 234

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Noninvasive Monitoring of Murine Tumor Blood Flow During and After Photodynamic Therapy Provides Early Assessment of Therapeutic Efficacy

Yu, Guoqiang, Durduran, Turgut, Zhou, Chao, Wang, Hsing-Wen, Putt, Mary E., Saunders, H. Mark, Sehgal, Chandra M., Glatstein, Eli, Yodh, Arjun G., Busch, Theresa M.·2005·Clinical Cancer Research

Abstract

Purpose: To monitor tumor blood flow noninvasively during photodynamic therapy (PDT) and to correlate flow responses with therapeutic efficacy. Experimental Design: Diffuse correlation spectroscopy (DCS) was used to measure blood flow continuously in radiation-induced fibrosarcoma murine tumors during Photofrin (5 mg/kg)/PDT (75 mW/cm2, 135 J/cm2). Relative blood flow (rBF; i.e., normalized to preillumination values) was compared with tumor perfusion as determined by power Doppler ultrasound and was correlated with treatment durability, defined as the time of tumor growth to a volume of 400 mm3. Broadband diffuse reflectance spectroscopy concurrently quantified tumor hemoglobin oxygen saturation (SO2). Results: DCS and power Doppler ultrasound measured similar flow decreases in animals treated with identical protocols. DCS measurement of rBF during PDT revealed a series of PDT-induced peaks and declines dominated by an initial steep increase (average ± SE: 168.1 ± 39.5%) and subsequent decrease (59.2 ± 29.1%). The duration (interval time; range, 2.2-15.6 minutes) and slope (flow reduction rate; range, 4.4 -45.8% minute−1) of the decrease correlated significantly (P = 0.0001 and 0.0002, r2 = 0.79 and 0.67, respectively) with treatment durability. A positive, significant (P = 0.016, r2 = 0.50) association between interval time and time-to-400 mm3 was also detected in animals with depressed pre-PDT blood flow due to hydralazine administration. At 3 hours after PDT, rBF and SO2 were predictive (P ≤ 0.015) of treatment durability. Conclusion: These data suggest a role for DCS in real-time monitoring of PDT vascular response as an indicator of treatment efficacy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1158/1078-0432.ccr-04-2582

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 234

Metadata

Authors
Yu, G., Durduran, T., Zhou, C., Wang, H.-W., Putt, M. E., Saunders, H. M., Sehgal, C. M., Glatstein, E., Yodh, A. G., & Busch, T. M.
Venue
Clinical Cancer Research
Published
2005-05-01
Volume
11
Issue
9
Pages
3543-3552
ISSN
  • 1078-0432 (ISSN-L)
  • 1557-3265
OpenAlex
W2048901783
Cited by
234
References
2
FWCI
9.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Monitoring of Murine Tumor Blood Flow During and After Photodynamic Therapy Provides Early Assessment of Therapeutic Efficacy. https://app.cochat.ai/papers/10.1158/1078-0432.ccr-04-2582
The paper
Yu, G., Durduran, T., Zhou, C., Wang, H.-W., Putt, M. E., Saunders, H. M., Sehgal, C. M., Glatstein, E., Yodh, A. G., & Busch, T. M. (2005). Noninvasive Monitoring of Murine Tumor Blood Flow During and After Photodynamic Therapy Provides Early Assessment of Therapeutic Efficacy. Clinical Cancer Research. https://doi.org/10.1158/1078-0432.ccr-04-2582

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.