The DOI matches its Crossref record.
High-Resolution Mapping of Tumor Redox Status by Magnetic Resonance Imaging Using Nitroxides as Redox-Sensitive Contrast Agents
Abstract
Purpose: There is considerable research directed toward the identification and development of functional contrast agents for medical imaging that superimpose tissue biochemical/molecular information with anatomical structures. Nitroxide radicals were identified as in vivo radioprotectors. Being paramagnetic, they can provide image contrast in magnetic resonance imaging (MRI) and electron paramagnetic resonance imaging (EPRI). The present study sought to determine the efficacy of nitroxide radioprotectors as functional image contrast agents. Experimental Design: Nitroxide radioprotectors, which act as contrast agents, were tested by EPRI and MRI to provide tissue redox status information noninvasively. Results: Phantom studies showed that the nitroxide, 3-carbamoyl-PROXYL (3CP), undergoes time-dependent reduction to the corresponding diamagnetic hydroxylamine only in the presence of reducing agents. The reduction rates of 3CP obtained by EPRI and MRI were in agreement suggesting the feasibility of using MRI to monitor nitroxide levels in tissues. The levels of 3CP were examined by EPRI and MRI for differences in reduction between muscle and tumor (squamous cell carcinoma) implanted in the hind leg of C3H mice simultaneously. In vivo experiments showed a T1-dependent image intensity enhancement afforded by 3CP which decreased in a time-dependent manner. Reduction of 3CP was found to be the dominant mechanism of contrast loss. The tumor regions exhibited a faster decay rate of the nitroxide compared to muscle (0.097 min-1 versus 0.067 min-1, respectively). Conclusions: This study shows that MRI can be successfully used to co-register tissue redox status along with anatomic images, thus providing potentially valuable biochemical information from the region of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zielonka, J., Joseph, J., Sikora, A., Hardy, M., Ouari, O., Vasquez-Vivar, J., Cheng, G., Lopez, M., & Kalyanaraman, B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00042 · Cited by 1,683
The chemistry and biology of nitroxide compounds
Soule, B. P., Hyodo, F., Matsumoto, K.-I., Simone, N. L., Cook, J. A., Krishna, M. C., & Mitchell, J. B. (2007) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2007.02.030 · Cited by 519
Self-citationRadioprotectors and mitigators of radiation-induced normal tissue injury
Citrin, D., Cotrim, A. P., Hyodo, F., Baum, B. J., Krishna, M. C., & Mitchell, J. B. (2010) · The Oncologist · doi:10.1634/theoncologist.2009-s104 · Cited by 482
Self-citationRedox-responsive branched-bottlebrush polymers for in vivo MRI and fluorescence imaging
Sowers, M. A., McCombs, J. R., Wang, Y., Paletta, J. T., Morton, S. W., Dreaden, E. C., Boska, M. D., Ottaviani, M. F., Hammond, P. T., Rajca, A., et al. (2014) · Nature Communications · doi:10.1038/ncomms6460 · Cited by 279
Metadata
- Authors
- Matsumoto, K.-I., Hyodo, F., Matsumoto, A., Koretsky, A. P., Sowers, A. L., Mitchell, J. B., & Krishna, M. C.
- Venue
- Clinical Cancer Research
- Published
- 2006-04-15
- Volume
- 12
- Issue
- 8
- Pages
- 2455-2462
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2153912174
- Cited by
- 167
- References
- 0
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Resolution Mapping of Tumor Redox Status by Magnetic Resonance Imaging Using Nitroxides as Redox-Sensitive Contrast Agents. https://app.cochat.ai/papers/10.1158/1078-0432.ccr-05-2747
- The paper
- Matsumoto, K.-I., Hyodo, F., Matsumoto, A., Koretsky, A. P., Sowers, A. L., Mitchell, J. B., & Krishna, M. C. (2006). High-Resolution Mapping of Tumor Redox Status by Magnetic Resonance Imaging Using Nitroxides as Redox-Sensitive Contrast Agents. Clinical Cancer Research. https://doi.org/10.1158/1078-0432.ccr-05-2747
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.