Sensitivity and Specificity of Cetuximab-IRDye800CW to Identify Regional Metastatic Disease in Head and Neck Cancer
Open accessThe DOI matches its Crossref record.
Abstract
Purpose: Comprehensive cervical lymphadenectomy can be associated with significant morbidity and poor quality of life. This study evaluated the sensitivity and specificity of cetuximab-IRDye800CW to identify metastatic disease in patients with head and neck cancer. Experimental Design: Consenting patients scheduled for curative resection were enrolled in a clinical trial to evaluate the safety and specificity of cetuximab-IRDye800CW. Patients (n = 12) received escalating doses of the study drug. Where indicated, cervical lymphadenectomy accompanied primary tumor resection, which occurred 3 to 7 days following intravenous infusion of cetuximab-IRDye800CW. All 471 dissected lymph nodes were imaged with a closed-field, near-infrared imaging device during gross processing of the fresh specimens. Intraoperative imaging of exposed neck levels was performed with an open-field fluorescence imaging device. Blinded assessments of the fluorescence data were compared to histopathology to calculate sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV). Results: Of the 35 nodes diagnosed pathologically positive, 34 were correctly identified with fluorescence imaging, yielding a sensitivity of 97.2%. Of the 435 pathologically negative nodes, 401 were correctly assessed using fluorescence imaging, yielding a specificity of 92.7%. The NPV was determined to be 99.7%, and the PPV was 50.7%. When 37 fluorescently false-positive nodes were sectioned deeper (1 mm) into their respective blocks, metastatic cancer was found in 8.1% of the recut nodal specimens, which altered staging in two of those cases. Conclusions: Fluorescence imaging of lymph nodes after systemic cetuximab-IRDye800CW administration demonstrated high sensitivity and was capable of identifying additional positive nodes on deep sectioning. Clin Cancer Res; 23(16); 4744–52. ©2017 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hu, Z., Fang, C., Li, B., Zhang, Z., Cao, C., Cai, M., Su, S., Sun, X., Shi, X., Li, C., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0494-0 · Cited by 1,126
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
Latest developments in molecular tracers for fluorescence image-guided cancer surgery
Hernot, S., van Manen, L., Debie, P., Mieog, J. S. D., & Vahrmeijer, A. L. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30317-1 · Cited by 471
NIR-II light in clinical oncology: opportunities and challenges
Zhang, Z., Du, Y., Shi, X., Wang, K., Qu, Q., Liang, Q., Ma, X., He, K., Chi, C., Tang, J., et al. (2024) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-024-00892-0 · Cited by 341
Near-infrared II fluorescence imaging
Schmidt, E. L., Ou, Z., Ximendes, E., Cui, H., Keck, C. H. C., Jaque, D., & Hong, G. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00301-x · Cited by 331
Metadata
- Authors
- Rosenthal, E. L., Moore, L. S., Tipirneni, K., de Boer, E., Stevens, T. M., Hartman, Y. E., Carroll, W. R., Zinn, K. R., & Warram, J. M.
- Venue
- Clinical Cancer Research
- Published
- 2017-08-14
- Volume
- 23
- Issue
- 16
- Pages
- 4744-4752
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2608695549
- Cited by
- 154
- References
- 0
- FWCI
- 12.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity and Specificity of Cetuximab-IRDye800CW to Identify Regional Metastatic Disease in Head and Neck Cancer. https://app.cochat.ai/papers/10.1158/1078-0432.ccr-16-2968
- The paper
- Rosenthal, E. L., Moore, L. S., Tipirneni, K., de Boer, E., Stevens, T. M., Hartman, Y. E., Carroll, W. R., Zinn, K. R., & Warram, J. M. (2017). Sensitivity and Specificity of Cetuximab-IRDye800CW to Identify Regional Metastatic Disease in Head and Neck Cancer. Clinical Cancer Research. https://doi.org/10.1158/1078-0432.ccr-16-2968
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.