CoChat

Fluorescein-Guided Surgery for Resection of High-Grade Gliomas: A Multicentric Prospective Phase II Study (FLUOGLIO)

Acerbi, Francesco, Broggi, Morgan, Schebesch, Karl-Michael, Höhne, Julius, Cavallo, Claudio, De Laurentis, Camilla, Eoli, Marica, Anghileri, Elena, Servida, Maura, Boffano, Carlo, Pollo, Bianca, Schiariti, Marco, Visintini, Sergio, Montomoli, Cristina, Bosio, Lorenzo, La Corte, Emanuele, Broggi, Giovanni, Brawanski, Alexander, Ferroli, Paolo · 2018 · Clinical Cancer Research
Cited by 229

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Purpose: Sodium fluorescein is a dye that, intravenously injected, selectively accumulates in high-grade glioma (HGG) tissue through a damaged blood–brain barrier. In this article, the final results of a multicentric prospective phase II trial (FLUOGLIO) on fluorescein-guided HGG resection through a dedicated filter on the surgical microscope were reported. Methods: Patients with suspected HGGs considered suitable for removal were eligible to participate in this trial. Fluorescein was intravenously injected at a dose of 5 to 10 mg/kg. The primary endpoint was the percentage of patients with histologically confirmed HGGs, without contrast-enhancing tumor at the immediate postoperative MRI. Secondary endpoints were PFS, residual tumor on postoperative MRI, overall survival, neurologic deficits, and fluorescein-related toxicity. The sensitivity and specificity of fluorescein in identifying tumor tissue were estimated by fluorescent and nonfluorescent biopsies at the tumor margin. The study was registered on the European Regulatory Authorities website (EudraCT 2011-002527-18). Results: Fifty-seven patients aged 45 to 75 years were screened for participation, and 46 were considered for primary and secondary endpoints. Mean preoperative tumor volume was 28.75 cm3 (range, 1.3–87.8 cm3). Thirty-eight patients (82.6%) underwent a complete tumor removal. Median follow-up was 11 months. PFS-6 and PFS-12 were 56.6% and 15.2%. Median survival was 12 months. No adverse reaction related to SF administration was recorded. The sensitivity and specificity of fluorescein in identifying tumor tissue were respectively 80.8% and 79.1%. Conclusions: Fluorescein-guided technique with a dedicated filter on the surgical microscope is safe and enables a high percentage of contrast-enhancing tumor in patients with HGGs. Clin Cancer Res; 24(1); 52–61. ©2017 AACR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1158/1078-0432.ccr-17-1184

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 229

Metadata

Authors
Acerbi, F., Broggi, M., Schebesch, K.-M., Höhne, J., Cavallo, C., De Laurentis, C., Eoli, M., Anghileri, E., Servida, M., Boffano, C., Pollo, B., Schiariti, M., Visintini, S., Montomoli, C., Bosio, L., La Corte, E., Broggi, G., Brawanski, A., & Ferroli, P.
Venue
Clinical Cancer Research
Published
2018-01-01
Volume
24
Issue
1
Pages
52-61
ISSN
  • 1078-0432 (ISSN-L)
  • 1557-3265
OpenAlex
W2763896294
Cited by
229
References
4
FWCI
9.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fluorescein-Guided Surgery for Resection of High-Grade Gliomas: A Multicentric Prospective Phase II Study (FLUOGLIO). https://app.cochat.ai/papers/10.1158/1078-0432.ccr-17-1184
The paper
Acerbi, F., Broggi, M., Schebesch, K.-M., Höhne, J., Cavallo, C., De Laurentis, C., Eoli, M., Anghileri, E., Servida, M., Boffano, C., Pollo, B., Schiariti, M., Visintini, S., Montomoli, C., Bosio, L., La Corte, E., Broggi, G., Brawanski, A., & Ferroli, P. (2018). Fluorescein-Guided Surgery for Resection of High-Grade Gliomas: A Multicentric Prospective Phase II Study (FLUOGLIO). Clinical Cancer Research. https://doi.org/10.1158/1078-0432.ccr-17-1184

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.