A Comparison of Underwater Bubble Continuous Positive Airway Pressure with Ventilator-Derived Continuous Positive Airway Pressure in Premature Neonates Ready for Extubation

Lee, Kyong-Soon, Dunn, Michael S., Fenwick, Marsha, Shennan, Andrew T.·1998·Neonatology

Abstract

Objective and methods: As the result of vigorous bubbling, infants receiving continuous positive airway pressure (CPAP) by an underwater seal (bubble CPAP) were observed to have vibrations of their chests at frequencies similar to high-frequency ventilation (HFV). We performed a randomized crossover study in 10 premature infants ready for extubation to test whether bubble CPAP contributes to gas exchange compared to conventional ventilator-derived CPAP. Measurements of tidal volume and minute volume were made using the Bear Cub neonatal volume monitor, and gas exchange was measured using an oxygen saturation monitor and a transcutaneous carbon dioxide (tcpCO 2) monitor. Results: There was a 39% reduction in minute volume (p < 0.001) and a 7% reduction in respiratory rate (p = 0.004) with no change in tcpCO 2 or O 2 saturation for infants supported with bubble versus ventilator-derived CPAP. Conclusions: The lack of difference in blood gas parameters associated with a decrease in the infant’s minute volume and respiratory rate with bubble CPAP compared with ventilator-derived CPAP suggests that the chest vibrations produced with bubble CPAP may have contributed to gas exchange. Bubble CPAP may offer an effective and inexpensive option for providing respiratory support to premature infants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000013962

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Lee, K.-S., Dunn, M. S., Fenwick, M., & Shennan, A. T.
Venue
Neonatology
Publisher
S. Karger AG
Published
1998
Volume
73
Issue
2
Pages
69-75
ISSN
  • 1661-7800 (ISSN-L)
  • 1661-7819
OpenAlex
W1964572487
Cited by
174
References
0
FWCI
0.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Underwater Bubble Continuous Positive Airway Pressure with Ventilator-Derived Continuous Positive Airway Pressure in Premature Neonates Ready for Extubation. https://app.cochat.ai/papers/10.1159/000013962
The paper
Lee, K.-S., Dunn, M. S., Fenwick, M., & Shennan, A. T. (1998). A Comparison of Underwater Bubble Continuous Positive Airway Pressure with Ventilator-Derived Continuous Positive Airway Pressure in Premature Neonates Ready for Extubation. Neonatology. https://doi.org/10.1159/000013962