Determination of 17-Hydroxyprogesterone in Plasma by Stable Isotope Dilution/Benchtop Liquid Chromatography-Tandem Mass Spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An assay based on stable isotope dilution liquid chromatography-tandem mass spectrometry (ID/LC-MS-MS) was developed for the quantification of 17-hydroxyprogesterone, the most important indicator of 21-hydroxylase deficiency in human plasma. Plasma was extracted using ethyl acetate and Extrelut® columns. LC was performed on a reversed-phase C18 column using a water/methanol gradient. A benchtop triple quadrupole mass spectrometer, operating in selected reaction monitoring mode, served as mass detector. The analytical run time was 9 min per sample. The sensitivity was high: 0.06 pmol of 17-hydroxyprogesterone yielded a signal-to-noise ratio of 13. Precision (CV) and accuracy (relative error) derived from the analyses of unspiked and spiked validation samples were 7.4–12.0% and 6.4%, respectively. When analyzing the same samples – median (range), in nanomoles per liter – from neonates and adults independently by ID/LC-MS-MS as well as by ID/gas chromatography (GC)-MS, corresponding results were obtained: neonates (n = 10), ID/LC-MS-MS 3.99 (0.48–16.05), ID/GC-MS 5.39 (1.57–13.02); adults (n = 10), ID/LC-MS-MS 2.66 (1.39–6.15), ID/GC-MS 2.54 (0.51–5.12). The technique permitted reliable detection of classical and nonclassical forms of 21- hydroxylase deficiency. The much simpler sample preparation, the faster analytical run time and the operational ease possible with ID/LC-MS-MS permit a considerable increase of sample testing per day without compromising on analytical sensitivity and specificity. We expect that benchtop tandem mass spectrometry will open new avenues in clinical steroid analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wudy, S. A., Wachter, U. A., Homoki, J., & Teller, W. M. (1995) · Pediatric Research · doi:10.1203/00006450-199507000-00013 · Cited by 69
Self-citation
Cited by
Lacey, J. M., Minutti, C. Z., Magera, M. J., Tauscher, A. L., Casetta, B., McCann, M., Lymp, J., Hahn, S. H., Rinaldo, P., & Matern, D. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.027193 · Cited by 216
Janzen, N., Peter, M., Sander, S., Steuerwald, U., Terhardt, M., Holtkamp, U., & Sander, J. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-2890 · Cited by 211
Forest, M. G. (2004) · Human Reproduction Update · doi:10.1093/humupd/dmh047 · Cited by 200
Rauh, M., Gröschl, M., Rascher, W., & Dörr, H. G. (2006) · Steroids · doi:10.1016/j.steroids.2006.01.015 · Cited by 170
Minutti, C. Z., Lacey, J. M., Magera, M. J., Hahn, S. H., McCann, M., Schulze, A., Cheillan, D., Dorche, C., Chace, D. H., Lymp, J. F., et al. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-032235 · Cited by 154
Metadata
- Authors
- Wudy, S. A., Hartmann, M., & Svoboda, M.
- Venue
- Hormone Research in Paediatrics
- Publisher
- S. Karger AG
- Published
- 2000
- Volume
- 53
- Issue
- 2
- Pages
- 68-71
- ISSN
- 1663-2818 (ISSN-L)
- 1663-2826
- OpenAlex
- W1973419737
- Cited by
- 56
- References
- 1
- FWCI
- 0.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of 17-Hydroxyprogesterone in Plasma by Stable Isotope Dilution/Benchtop Liquid Chromatography-Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1159/000023516
- The paper
- Wudy, S. A., Hartmann, M., & Svoboda, M. (2000). Determination of 17-Hydroxyprogesterone in Plasma by Stable Isotope Dilution/Benchtop Liquid Chromatography-Tandem Mass Spectrometry. Hormone Research in Paediatrics. https://doi.org/10.1159/000023516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.