Electron Microscopy of the Canine Corneal Basement Membranes
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to characterize the surface topographical features of the epithelial and endothelial (Descemet’s) basement membranes of the canine cornea. Corneas were obtained from young, healthy dogs (<2 years old) with no history or evidence of previous ocular disease. The epithelium and endothelium was carefully removed preserving the anterior and posterior basement membranes. The specimens were examined by transmission electron microscopy and scanning electron microscopy. The epithelial and endothelial basement membrane surface topography is an intricate meshwork of pores and fibers measuring in the nanometer size range. The features of the endothelial basement membrane overall are smaller in size than the epithelial basement membrane. These surface topographical features may incite changes in epithelial and endothelial cell behavior.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In vivo extracellular matrix (ECM) architecture shown in scanning electron micrographs of basement membranes and collagen fibers often reveal a topography of pores, ridges and fibrillar structures at the micron and nanometer scales [30, 31].”
From Characterization of topographical effects on macrophage behavior in a foreign body response model (2010) · cites this paper as [30]
Citations
Cites
THE USE OF LEAD CITRATE AT HIGH pH AS AN ELECTRON-OPAQUE STAIN IN ELECTRON MICROSCOPY
Reynolds, E. S. (1963) · The Journal of Cell Biology · doi:10.1083/jcb.17.1.208 · Cited by 24,938 · cited 1×
“Cross-sections of the corneas were embedded in epoxy resin and thin sections (approximately 70 nm) were obtained [Reynolds, 1963; Mollenhauer, 1964].”
MethodPLASTIC EMBEDDING MIXTURES FOR USE IN ELECTRON MICROSCOPY.
Mollenhauer, H. H. (1964) · PubMed · Cited by 1,972
Signal transduction from the extracellular matrix.
Juliano, R. L., & Haskill, S. (1993) · The Journal of cell biology · doi:10.1083/jcb.120.3.577 · Cited by 1,683
Effects of synthetic micro- and nano-structured surfaces on cell behavior
Flemming, R. G., Murphy, C. J., Abrams, G. A., Goodman, S. L., & Nealey, P. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00209-9 · Cited by 1,450
Self-citationExpression of extracellular matrix components is regulated by substratum.
Streuli, C. H., & Bissell, M. J. (1990) · The Journal of cell biology · doi:10.1083/jcb.110.4.1405 · Cited by 345
Abrams, G. A., Goodman, S. L., Nealey, P. F., Franco, M., & Murphy, C. J. (2000) · Cell and Tissue Research · doi:10.1007/s004419900074 · Cited by 292 · cited 1×
“5, table 2) [Abrams et al., 2000a, b].”
Self-citationAbrams, G. A., Schaus, S. S., Goodman, S. L., Nealey, P. F., & Murphy, C. J. (2000) · Cornea · doi:10.1097/00003226-200001000-00012 · Cited by 182
Self-citationSaad, B., Hirt, T. D., Welti, M., Uhlschmid, G. K., Neuenschwander, P., & Suter, U. W. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1<65::aid-jbm8>3.0.co;2-j · Cited by 135
Morphology of the basement membrane
Merker, H. (1994) · Microscopy Research and Technique · doi:10.1002/jemt.1070280203 · Cited by 125 · cited 1×
“252 Cells Tissues Organs 2002;170:251–257 Abrams/Bentley/Nealey/Murphy Early microscopy studies have established that basement membranes have distinguishing topographical features [Inoue, 1994; Merker, 1994; Ruben and Yurchenco, 1994].”
BackgroundYagmurlu, M. F., Korkusuz, F., G�rsel, I., Korkusuz, P., �rs, �., & Hasirci, V. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990915)46:4<494::aid-jbm7>3.0.co;2-e · Cited by 114
Coordinated appearance of beta 1 integrins and fibronectin during corneal wound healing.
Murakami, J., Nishida, T., & Otori, T. (1992) · PubMed · Cited by 98
Bentley, E., Abrams, G. A., Covitz, D., Cook, C. S., Fischer, C. A., Hacker, D. V., Stuhr, C. M., Reid, T. W., & Murphy, C. J. (2001) · PubMed · Cited by 95
Self-citationMatrix stimulates the proliferation of human corneal endothelial cells in culture.
Blake, D. A., Yu, H., Young, D. L. W., & Caldwell, D. R. (1997) · PubMed · Cited by 93
Isolation of corneal epithelium with Dispase II or EDTA. Effects on the basement membrane zone.
Spurr-Michaud, S. J., & Gipson, I. K. (1985) · PubMed · Cited by 69
Stepp, M. A., & Zhu, L. F. (1997) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215549704500205 · Cited by 65
Steele, J. G., Johnson, G., McLean, K. M., Beumer, G. J., & Griesser, H. J. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000615)50:4<475::aid-jbm2>3.0.co;2-g · Cited by 58 · cited 1×
“For example, corneal epithelial cell adhesion and migration were altered by surface porosity [Evans et al., 1999; Steele et al., 2000].”
BackgroundPlasma surface modification of artificial corneas for optimal epithelialization
Latkany, R., Tsuk, A. G., Sheu, M.-S., Loh, I. H., & Trinkaus‐Randall, V. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1<29::aid-jbm4>3.0.co;2-n · Cited by 58 · cited 1×
“Several groups have investigated modifying the surface chemistry of the prosthetic through the addition of proteins or plasma coating to allow for epithelialization to occur [Trinkaus-Randall et al., 1988b; Sipehia et al., 1990; Latkany et al., 1997].”
Development of a biopolymeric keratoprosthetic material. Evaluation in vitro and in vivo.
Trinkaus‐Randall, V., Capecchi, J., Newton, A., Vadasz, A. G., Leibowitz, H. M., & Franzblau, C. (1988) · PubMed · Cited by 56
Basic structure of basement membranes is a fine network of “cords,” irregular anastomosing strands
Inoue, S. (1994) · Microscopy Research and Technique · doi:10.1002/jemt.1070280105 · Cited by 50 · cited 1×
“252 Cells Tissues Organs 2002;170:251–257 Abrams/Bentley/Nealey/Murphy Early microscopy studies have established that basement membranes have distinguishing topographical features [Inoue, 1994; Merker, 1994; Ruben and Yurchenco, 1994].”
BackgroundPersistent adhesion of epithelial tissue is sensitive to polymer topography
Evans, M. D. M., Dalton, B. A., & Steele, J. G. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990915)46:4<485::aid-jbm6>3.0.co;2-f · Cited by 50
Maser, M. D., & Trimble, J. J. (1977) · Journal of Histochemistry & Cytochemistry · doi:10.1177/25.4.67137 · Cited by 44
In vivo fibroplasia of a porous polymer in the cornea.
Trinkaus‐Randall, V., Banwatt, R., Capecchi, J., Leibowitz, H. M., & Franzblau, C. (1991) · PubMed · Cited by 37
High resolution platinum‐carbon replication of freeze‐dried basement membrane
Ruben, G. C., & Yurchenco, P. D. (1994) · Microscopy Research and Technique · doi:10.1002/jemt.1070280104 · Cited by 37
Kirschner, S. E. (1990) · Veterinary Clinics of North America Small Animal Practice · doi:10.1016/s0195-5616(90)50054-6 · Cited by 36 · cited 1×
“The basement membrane in this disease has been suggested to be abnormal [Kirschner et al., 1989; Kirschner, 1990].”
BackgroundThe Cardona Keratoprosthesis: 40 Years Experience
Cardona, H. (1991) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19911101-24 · Cited by 32 · cited 2×
“The major complications leading to failure of cornea prosthetics developed to date include leakage, infection, epithelial down growth around the prosthetic, tissue necrosis and eventually extrusion of the implant [Cardona, 1991; Trinkaus-Randall et al., 1991; Girard, 1993; Drubaix et al., 1996; Vijayasekaran et al., 1…”
BackgroundCollagen Synthesized in Fluorocarbon Polymer Implant in the Rabbit Cornea
Drubaix, I., Legeais, J., Malek-Chéhire, N., Savoldelli, M., Ménasche, M., Robert, L., Renard, G. J., & Pouliquen, Y. J. M. (1996) · Experimental Eye Research · doi:10.1006/exer.1996.0042 · Cited by 28 · cited 2×
“The major complications leading to failure of cornea prosthetics developed to date include leakage, infection, epithelial down growth around the prosthetic, tissue necrosis and eventually extrusion of the implant [Cardona, 1991; Trinkaus-Randall et al., 1991; Girard, 1993; Drubaix et al., 1996; Vijayasekaran et al., 1…”
BackgroundWu, X. Y., Svoboda, K. K. H., & Trinkaus‐Randall, V. (1995) · Experimental Eye Research · doi:10.1016/s0014-4835(05)80101-0 · Cited by 27 · cited 1×
“It has been demonstrated that the distribution of integrins and basement membrane ligands changes during corneal wound healing and in response to different underlying substrata [Murakami et al., 1992; Wu et al., 1995; Stepp and Zhu, 1977].”
BackgroundInfluence of substratum on corneal epithelial cell growth and protein synthesis.
Trinkaus‐Randall, V., Newton, A., & Franzblau, C. (1988) · PubMed · Cited by 26
Histologic Evaluation During Healing of Hydrogel Core-and-Skirt Keratoprostheses in the Rabbit Eye
Vijayasekaran, S., Hicks, C. R., Chirilă, T. V., Fitton, J. H., Clayton, A. B., Lou, X., Platten, S. T., Crawford, G. J., & Constable, I. J. (1997) · Cornea · doi:10.1097/00003226-199705000-00017 · Cited by 26 · cited 2×
“The major complications leading to failure of cornea prosthetics developed to date include leakage, infection, epithelial down growth around the prosthetic, tissue necrosis and eventually extrusion of the implant [Cardona, 1991; Trinkaus-Randall et al., 1991; Girard, 1993; Drubaix et al., 1996; Vijayasekaran et al., 1…”
BackgroundSipehia, R., Garfinkle, A. M., Jackson, W. B., & Chang, T. M. S. (1990) · Biomaterials Artificial Cells and Artificial Organs · doi:10.3109/10731199009117333 · Cited by 22
Research works printed but not linked: 1
- 10.1002/(sici)1097-4636(199707)36:1<29::aid-jbm4>3.3.co;2-3 · doi:10.1002/(sici)1097-4636(199707)36:1<29::aid-jbm4>3.3.co;2-3
Cited by
Epithelial contact guidance on well-defined micro- and nanostructured substrates
Teixeira, A. I., Abrams, G. A., Bertics, P. J., Murphy, C. J., & Nealey, P. F. (2003) · Journal of Cell Science · doi:10.1242/jcs.00383 · Cited by 978
“Basement membranes have a felt-like appearance with pores and fibers of nanoscale dimensions (Abrams et al., 2002; Abrams et al., 2000a; Abrams et al., 2000b; Hironaka et al., 1993; Inoue, 1994; Kubosawa and Kondo, 1994; Merker, 1994; Ruben and Yurchenco, 1994; Shirato et al., 1991; Yamasaki et…”
BackgroundSelf-citationMatrix nanotopography as a regulator of cell function
Kim, D.-H., Provenzano, P. P., Smith, C. L., & Levchenko, A. (2012) · Journal of Cell Biology · doi:10.1083/jcb.201108062 · Cited by 575
Characterization of topographical effects on macrophage behavior in a foreign body response model
Chen, S., Jones, J. A., Xu, Y., Low, H.-Y., Anderson, J. M., & Leong, K. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.074 · Cited by 389
“In vivo extracellular matrix (ECM) architecture shown in scanning electron micrographs of basement membranes and collagen fibers often reveal a topography of pores, ridges and fibrillar structures at the micron and nanometer scales [30,31].”
Karuri, N. W., Liliensiek, S., Teixeira, A. I., Abrams, G., Campbell, S., Nealey, P. F., & Murphy, C. J. (2004) · Journal of Cell Science · doi:10.1242/jcs.01146 · Cited by 299
“…porcine periodontal ligament explants, explants from human gingival fibroblasts, human corneal epithelial cells and central nervous system neurites (Abrams et al., 2002b; Brunette, 1986a; Brunette, 1986b; Flemming et al., 1999; Rajnicek et al., 1997; Rajnicek and McCaig, 1997; Teixeira et al.,…”
BackgroundSelf-citationThe Role of Electrospinning in the Emerging Field of Nanomedicine
Chew, S., Wen, Y., Dzenis, Y., & Leong, K. (2006) · Current Pharmaceutical Design · doi:10.2174/138161206779026326 · Cited by 277
Metadata
- Authors
- Abrams, G. A., Bentley, E., Nealey, P. F., & Murphy, C. J.
- Affiliations
- University of Wisconsin–Madison (US)
- Venue
- Cells Tissues Organs
- Publisher
- S. Karger AG
- Published
- 2002
- Volume
- 170
- Issue
- 4
- Pages
- 251-257
- ISSN
- 1422-6405 (ISSN-L)
- 1422-6421
- OpenAlex
- W1980068631
- Cited by
- 70
- References
- 28
- Citations by year
- 2024: 1 · 2022: 4 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 4 · 2016: 1 · 2015: 4 · 2014: 7 · 2013: 4 · 2012: 4
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.karger.com/Services/SiteLicenses (vor)
- www.karger.com/Services/SiteLicenses (tdm)
- Locations
- Cells Tissues Organs (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
- Health Sciences › Medicine › Ophthalmology › Corneal Surgery and Treatments
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Keywords
- corneal basement membrane, canine cornea, corneal epithelium, Descemet's membrane, corneal endothelium
- MeSH terms
- Animals, Basement Membrane, Cornea, Dogs, Humans, Immunohistochemistry, Macaca mulatta, Microscopy, Electron, Scanning, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.