EEMCO Guidance for the Assessment of Transepidermal Water Loss in Cosmetic Sciences
Abstract
Measurement of transepidermal water loss (TEWL), based on the estimation of the water vapour gradient in an open chamber, is being used to support claims of cosmetics including product mildness, reduction in irritative skin reactions, skin hydration, skin repair, protective effect against UV damage and others. TEWL measurement can also screen ingredients that have a beneficial effect on the barrier function and offer the possibility to monitor in vivo, on human skin, the effect of topical treatment in an objective and non-invasive way. A high number of variables affecting TEWL measurements have been identified. These should be rigorously taken into consideration. To work under standardised conditions is of the utmost importance to obtain reliable and reproducible results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pinnagoda, J., Tupkek, R. A., Agner, T., & Serup, J. (1990) · Contact Dermatitis · doi:10.1111/j.1600-0536.1990.tb01553.x · Cited by 1,092
Stratum corneum lipids: the effect of ageing and the seasons
Rogers, J., Harding, C., Mayo, A., Banks, J., & Rawlings, A. (1996) · Archives of Dermatological Research · doi:10.1007/bf02505294 · Cited by 415
WILSON, D., BERARDESCA, E., & MAIBACH, H. I. (1988) · International Journal of Cosmetic Science · doi:10.1111/j.1467-2494.1988.tb00018.x · Cited by 22
Cited by
Natural skin surface pH is on average below 5, which is beneficial for its resident flora
Lambers, H., Piessens, S., Bloem, A., Pronk, H., & Finkel, P. (2006) · International Journal of Cosmetic Science · doi:10.1111/j.1467-2494.2006.00344.x · Cited by 909
Role of Topical Emollients and Moisturizers in the Treatment of Dry Skin Barrier Disorders
Lod??n, M. (2003) · American Journal of Clinical Dermatology · doi:10.2165/00128071-200304110-00005 · Cited by 539
Nikolovski, J., Stamatas, G. N., Kollias, N., & Wiegand, B. C. (2008) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5701239 · Cited by 388
Fluhr, J. W., Feingold, K. R., & Elias, P. M. (2006) · Experimental Dermatology · doi:10.1111/j.1600-0625.2006.00437.x · Cited by 262
In vivo investigations on the penetration of various oils and their influence on the skin barrier
Patzelt, A., Lademann, J., Richter, H., Darvin, M. E., Schanzer, S., Thiede, G., Sterry, W., Vergou, T., & Hauser, M. (2012) · Skin Research and Technology · doi:10.1111/j.1600-0846.2011.00578.x · Cited by 137
Metadata
- Authors
- Rogiers, V.
- Venue
- Skin Pharmacology and Physiology
- Publisher
- S. Karger AG
- Published
- 2001
- Volume
- 14
- Issue
- 2
- Pages
- 117-128
- ISSN
- 1422-2868 (ISSN-L)
- 1660-5527
- 1660-5535
- OpenAlex
- W2052742156
- Cited by
- 525
- References
- 3
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EEMCO Guidance for the Assessment of Transepidermal Water Loss in Cosmetic Sciences. https://app.cochat.ai/papers/10.1159/000056341
- The paper
- Rogiers, V. (2001). EEMCO Guidance for the Assessment of Transepidermal Water Loss in Cosmetic Sciences. Skin Pharmacology and Physiology. https://doi.org/10.1159/000056341
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.