The DOI matches its Crossref record.
Calibrated Automated Thrombin Generation Measurement in Clotting Plasma
Open accessAbstract
Calibrated automated thrombography displays the concentration of thrombin in clotting plasma with or without platelets (platelet-rich plasma/platelet-poor plasma, PRP/PPP) in up to 48 samples by monitoring the splitting of a fluorogenic substrate and comparing it to a constant known thrombin activity in a parallel, non-clotting sample. Thus, the non-linearity of the reaction rate with thrombin concentration is compensated for, and adding an excess of substrate can be avoided. Standard conditions were established at which acceptable experimental variation accompanies sensitivity to pathological changes. The coefficients of variation of the surface under the curve (endogenous thrombin potential) are: within experiment ∼3%; intra-individual: <5% in PPP, <8% in PRP; interindividual 15% in PPP and 19% in PRP. In PPP, calibrated automated thrombography shows all clotting factor deficiencies (except factor XIII) and the effect of all anticoagulants [AVK, heparin(-likes), direct inhibitors]. In PRP, it is diminished in von Willebrand’s disease, but it also shows the effect of platelet inhibitors (e.g. aspirin and abciximab). Addition of activated protein C (APC) or thrombomodulin inhibits thrombin generation and reflects disorders of the APC system (congenital and acquired resistance, deficiencies and lupus antibodies) independent of concomitant inhibition of the procoagulant pathway as for example by anticoagulants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Polyphosphate modulates blood coagulation and fibrinolysis
Smith, S. A., Mutch, N. J., Baskar, D., Rohloff, P., Docampo, R., & Morrissey, J. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507195103 · Cited by 549
Laboratory diagnosis of the antiphospholipid syndrome: a plethora of obstacles to overcome
Devreese, K., & Hoylaerts, M. F. (2009) · European Journal Of Haematology · doi:10.1111/j.1600-0609.2009.01243.x · Cited by 78
Fibrinogen and fibrin are novel substrates for Fasciola hepatica cathepsin L peptidases
Mebius, M. M., Op Heij, J. M. J., Tielens, A. G. M., de Groot, P. G., Urbanus, R. T., & van Hellemond, J. J. (2018) · Molecular and Biochemical Parasitology · doi:10.1016/j.molbiopara.2018.02.001 · Cited by 19
Metadata
- Authors
- Hemker, H. C., Giesen, P., Al Dieri, R., Regnault, V., de Smedt, E., Wagenvoord, R., Lecompte, T., & Béguin, S.
- Venue
- Pathophysiology of Haemostasis and Thrombosis
- Publisher
- S. Karger AG
- Published
- 2003
- Volume
- 33
- Issue
- 1
- Pages
- 4-15
- ISSN
- 1424-8832 (ISSN-L)
- 1424-8840
- OpenAlex
- W2119768870
- Cited by
- 1,430
- References
- 0
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibrated Automated Thrombin Generation Measurement in Clotting Plasma. https://app.cochat.ai/papers/10.1159/000071636
- The paper
- Hemker, H. C., Giesen, P., Al Dieri, R., Regnault, V., de Smedt, E., Wagenvoord, R., Lecompte, T., & Béguin, S. (2003). Calibrated Automated Thrombin Generation Measurement in Clotting Plasma. Pathophysiology of Haemostasis and Thrombosis. https://doi.org/10.1159/000071636
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.