CoChat

Effects of Training on the Tolerance to High-Intensity Exercise in Patients with Severe COPD

Puente-Maestu, Luis, SantaCruz, Antonio, Vargas, Teresa, Martínez-Abad, Yolanda, Whipp, Brian J. · 2003 · Respiration
Cited by 46

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: There has been no systemic investigation of the effects of training on endurance at different high-intensity work rates in patients with COPD to date. Objectives: We wanted to determine the effects of intense endurance training on tolerance to several high-intensity work rates and to establish the relationship between power (WR) and its tolerable duration (t) (t = W’/(WR – CP), being W’, the curvature constant, thought to be reflective of anaerobic energy availability and/or tolerance to the uncomfortable sensations associated with the high-intensity exercise, and CP the critical power. Methods: We studied 27 patients: age 62 ± 5 years; FEV 1 1.2 ± 0.2 liters. Before and after the intervention, the subjects randomly underwent 4 high-intensity constant WR exercise tests. The endurance times of the highest 3 tests were used. Results: Ventilation reached approximately the same level in each of the tests. In response to the training, the average peak increased by 9 ± 5% (p < 0.0001), CP by 14 ± 12% (p < 0.0001) and W’ 18 ± 22% (p = 0.002). In 67% of the patients, CP increased, accompanied by changes in other related physiological variables of aerobic capacity. In the remaining 33%, W’ increased but not CP. Smaller or no changes in the other variables of aerobic capacity were found in those subjects. This latter group was significantly older and had more hyperinflation (i.e. higher RV/TLC%). Conclusions: Our results suggest that neither an incremental nor a single endurance test at constant WR provides an adequate characterisation of exercise tolerance at other WRs. CP and W’ appear to be important parameters characterizing exercise tolerance over a range high-intensity work rates and identifying two distinct types of response to training.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000072899

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Puente-Maestu, L., SantaCruz, A., Vargas, T., Martínez-Abad, Y., & Whipp, B. J.
Venue
Respiration
Publisher
S. Karger AG
Published
2003
Volume
70
Issue
4
Pages
367-370
ISSN
  • 0025-7931 (ISSN-L)
  • 1423-0356
OpenAlex
W2034714226
Cited by
46
References
1
FWCI
6.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.