Implantation of a Closed-Loop Stimulation in the Management of Medically Refractory Focal Epilepsy
The DOI matches its Crossref record.
Abstract
Open-loop stimulation studies have shown varying control of seizures with stimulation of different anatomical targets. A recent multi-institutional clinical study utilizing an external closed-loop stimulation system had promising results. A novel implantable closed-loop Responsive Neurostimulation System (RNS) (Neuropace, Inc., Mountainview, Calif., USA) consisting of a cranially implanted pulse generator, one or two quadripolar subdural strip or depth leads and a programmer is under testing in a prospective clinical trial. The RNS pulse generator continuously analyzes the patient’s electrocortigrams (ECoGs) and automatically triggers electrical stimulation when specific ECoG characteristics programmed by the clinician, as indicative of electrographic seizures or precursor of epileptiform activities, are detected. The pulse generator then stores diagnostic information detailing detections and stimulations, including multichannel stored ECoGs. The RNS programmer communicates transcutaneously with the implanted pulse generator when initiated by a clinician. The RNS programmer can download diagnostics and store ECoGs for review. The RNS programmer can then be used to program detection and stimulation parameters. In our current communication, we describe the selection criteria for implanting this system, the preparation of the surgical candidates as well as the surgical technique. We also present our preliminary results with 8 patients who had an RNS implanted. Seven patients (87.5%) had more than 45% decrease in their seizure frequency. The mean follow-up time in our series was 9.2 months. The implantation of a closed-loop stimulation system, in our experience, represents a safe and relatively simple surgical procedure. However, the efficacy of this new treatment modality remains to be determined in further multi-institutional, prospective clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Seizure prediction: the long and winding road
Mormann, F., Andrzejak, R. G., Elger, C. E., & Lehnertz, K. (2007) · Brain · doi:10.1093/brain/awl241 · Cited by 1,109
Electrical brain stimulation for epilepsy
Fisher, R. S., & Velasco, A. L. (2014) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.59 · Cited by 402
Intractable epilepsy: management and therapeutic alternatives
Schuele, S. U., & Lüders, H. O. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70108-x · Cited by 344
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Brain stimulation for epilepsy: can scheduled or responsive neurostimulation stop seizures?
Morrell, M. (2006) · Current Opinion in Neurology · doi:10.1097/01.wco.0000218233.60217.84 · Cited by 208
Seizure prediction for therapeutic devices: A review
Gadhoumi, K., Lina, J.-M., Mormann, F., & Gotman, J. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.06.010 · Cited by 190
Refractory epilepsy: mechanisms and solutions
Kwan, P., & Brodie, M. J. (2006) · Expert Review of Neurotherapeutics · doi:10.1586/14737175.6.3.397 · Cited by 179
Abdelhalim, K., Jafari, H. M., Kokarovtseva, L., Velazquez, J. L. P., & Genov, R. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2272952 · Cited by 124
Deep brain stimulation: current and future perspectives
Awan, N. R., Lozano, A., & Hamani, C. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0982 · Cited by 83
Metadata
- Authors
- Fountas, K. N., Smith, J. R., Murro, A. M., Politsky, J., Park, Y. D., & Jenkins, P. D.
- Venue
- Stereotactic and Functional Neurosurgery
- Publisher
- S. Karger AG
- Published
- 2005
- Volume
- 83
- Issue
- 4
- Pages
- 153-158
- ISSN
- 1011-6125 (ISSN-L)
- 1423-0372
- OpenAlex
- W1986518373
- Cited by
- 138
- References
- 0
- FWCI
- 5.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.