64-Channel UWB Wireless Neural Vector Analyzer SOC With a Closed-Loop Phase Synchrony-Triggered Neurostimulator
Abstract
An ultra wideband (UWB) 64-channel responsive neural stimulator system-on-chip (SoC) is presented. It demonstrates the first on-chip neural vector analyzer capable of wirelessly monitoring magnitude, phase and phase synchronization of neural signals. In a closed-loop, abnormal phase synchrony triggers the programmable-waveform biphasic current-mode neural stimulator. To implement these functionalities, the SoC integrates 64 neural recording amplifiers with tunable switched-capacitor (SC) bandpass filters, 64 multiplying 8-bit SAR ADCs, 64 programmable 16-tap FIR filters, a tri-core CORDIC processor, 64 biphasic current stimulation channels, and a 3.1-10.6 GHz UWB wireless transmitter onto a 4 mm × 3 mm 0.13 μm CMOS die. To minimize both the area and power dissipation of the SoC, the SAR ADC is re-used as a multiplier for FIR filtering and as a DAC and duty cycle controller for the biphasic neural stimulator. The SoC has been validated in the early detection and abortion of seizures in freely moving rodents on-line and in early seizure detection in humans off-line.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
It is common for multiple amplifier channels to share a single ADC or output driver in a time-multiplexed sequence.
“For example, it is common for multiple amplifier channels to share a single ADC or output driver in a time-multiplexed sequence [1, 51, 73, 94].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [1]
Cites
The size and burden of mental disorders and other disorders of the brain in Europe 2010
Wittchen, H. U., Jacobi, F., Rehm, J., Gustavsson, A., Svensson, M., Jönsson, B., Olesen, J., Allgulander, C., Alonso, J., Faravelli, C., et al. (2011) · European Neuropsychopharmacology · doi:10.1016/j.euroneuro.2011.07.018 · Cited by 3,754 · see citing works
High Gamma Power Is Phase-Locked to Theta Oscillations in Human Neocortex
Canolty, R. T., Edwards, E., Dalal, S. S., Soltani, M., Nagarajan, S. S., Kirsch, H. E., Berger, M. S., Barbaro, N. M., & Knight, R. T. (2006) · Science · doi:10.1126/science.1128115 · Cited by 2,650 · see citing works
Neural synchrony in brain disorders: Relevance for cognitive dysfunctions and pathophysiology
Uhlhaas, P. J., & Singer, W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.020 · Cited by 2,194 · see citing works
Abnormal neural oscillations and synchrony in schizophrenia
Uhlhaas, P. J., & Singer, W. (2010) · Nature Reviews Neuroscience · doi:10.1038/nrn2774 · Cited by 2,120 · see citing works
Mormann, F., Lehnertz, K., David, P., & Elger, C. E. (2000) · Physica D Nonlinear Phenomena · doi:10.1016/s0167-2789(00)00087-7 · Cited by 1,287 · see citing works
Normal and pathological oscillatory communication in the brain
Schnitzler, A., & Groß, J. (2005) · Nature reviews. Neuroscience · doi:10.1038/nrn1650 · Cited by 1,229 · see citing works
Seizure prediction: the long and winding road
Mormann, F., Andrzejak, R. G., Elger, C. E., & Lehnertz, K. (2006) · Brain · doi:10.1093/brain/awl241 · Cited by 1,112 · see citing works
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782 · see citing works
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R. R., Watkins, P., Kier, R. J., Lovejoy, R. O., Black, D., Normann, R. A., & Solzbacher, F. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696288 · Cited by 731 · see citing works
Jiles, R. B., Hughes, E., Murphy, W., Flowers, N., McCracken, M., Roberts, H., Ochner, M., Balluz, L. S., Mokdad, A., Elam–Evans, L. D., et al. (2005) · PubMed · Cited by 596 · see citing works
50 Years of CORDIC: Algorithms, Architectures, and Applications
Meher, P. K., Valls, J., Juang, T., et al. (2009) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2009.2025803 · Cited by 583 · see citing works
Verma, N., Shoeb, A. H., Bohorquez, J. L., Dawson, J. L., Guttag, J. V., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 528 · see citing works
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478 · see citing works
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369 · see citing works
Responsive Cortical Stimulation for the Treatment of Epilepsy
Sun, F. T., Morrell, M. J., & Wharen, R. E. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.069 · Cited by 310 · see citing works
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263 · see citing works
Self-citationA $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring
Xu, J., Yazıcıoğlu, R. F., Grundlehner, B., Harpe, P. J. A., Makinwa, K. A. A., & Hoof, C. A. V. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2170985 · Cited by 221 · see citing works
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220 · see citing works
HermesE: A 96-Channel Full Data Rate Direct Neural Interface in 0.13 $\mu$m CMOS
Gao, H., Walker, R. M., Nuyujukian, P., Makinwa, K. A. A., Shenoy, K. V., Murmann, B., & Meng, T. H. Y. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185338 · Cited by 189 · see citing works
256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes
Aziz, J. N. Y., Abdelhalim, K., Shulyzki, R., Genov, R., Bardakjian, B. L., Derchansky, M., Serletis, D., & Carlen, P. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010997 · Cited by 184 · see citing works
Self-citationAzin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2108770 · Cited by 164 · see citing works
Mollazadeh, M., Murari, K., Cauwenberghs, G., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2005297 · Cited by 161 · see citing works
A 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W. A., Carlson, D., Jensen, R. M., Stanslaski, S. R., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 143 · see citing works
Lee, J., Rhew, H.-G., Kipke, D. R., & Flynn, M. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2052403 · Cited by 140 · see citing works
Implantation of a Closed-Loop Stimulation in the Management of Medically Refractory Focal Epilepsy
Fountas, K. N., Smith, J. R., Murro, A. M., Politsky, J. M., Park, Y. D., & Jenkins, P. D. (2005) · Stereotactic and Functional Neurosurgery · doi:10.1159/000088656 · Cited by 139 · see citing works
CMOS Microelectrode Array for Bidirectional Interaction With Neuronal Networks
Heer, F., Hafizovic, S., Franks, W., Blau, A. W., Ziegler, C., & Hierlemann, A. R. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.873677 · Cited by 134 · see citing works
Mercier, P. P., Daly, D. C., & Chandrakasan, A. P. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2020466 · Cited by 124 · see citing works
Lee, S. B., Lee, H., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2010.5434028 · Cited by 121 · see citing works
Design Optimization for Integrated Neural Recording Systems
Chae, M. S., Liu, W., & Sivaprakasam, M. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2001877 · Cited by 119 · see citing works
A Wireless Integrated Circuit for 100-Channel Charge-Balanced Neural Stimulation
Thurgood, B., Warren, D. J., Ledbetter, N. M., Clark, G. A., & Harrison, R. R. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2032268 · Cited by 93 · see citing works
An All-Digital 12 pJ/Pulse IR-UWB Transmitter Synthesized From a Standard Cell Library
Park, Y.-M., & Wentzloff, D. D. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2112232 · Cited by 75 · see citing works
Yoo, J., Yan, L., El-Damak, D. R., et al. (2012) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2012.6177019 · Cited by 67 · see citing works
Phase-Synchronization Early Epileptic Seizure Detector VLSI Architecture
Abdelhalim, K., Smolyakov, V., & Genov, R. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2170686 · Cited by 59 · see citing works
Self-citationBonfanti, A. G., Ceravolo, M., Zambra, G., Gusmeroli, R., Borghi, T., Spinelli, A. S., & Lacaita, A. L. (2010) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2010.5619710 · Cited by 34 · see citing works
Velázquez, J. L. P., Dominguez, L. G., Nenadovic, V., et al. (2010) · Journal of Biological Physics · doi:10.1007/s10867-010-9205-5 · Cited by 28 · see citing works
A Low-Voltage Energy-Sampling IR-UWB Digital Baseband Employing Quadratic Correlation
Mercier, P. P., Bhardwaj, M., Daly, D. C., et al. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2046245 · Cited by 27 · see citing works
256-site active neural probe and 64-channel responsive cortical stimulator
Shulyzki, R., Abdelhalim, K., Bagheri, A., et al. (2011) · IEEE Custom Integrated Circuits Conference (CICC) · doi:10.1109/cicc.2011.6055371 · Cited by 24 · see citing works
Self-citation915-MHz wireless 64-channel neural recording SoC with programmable mixed-signal FIR filters
Abdelhalim, K., & Genov, R. (2011) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2011.6044947 · Cited by 20 · see citing works
Self-citation128-channel fully differential digital neural recording and stimulation interface
Shahrokhi, F., Abdelhalim, K., & Genov, R. (2009) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2009.5117989 · Cited by 18 · see citing works
Self-citation64-Channel UWB wireless neural vector analyzer and phase synchrony-triggered stimulator SoC
Abdelhalim, K., Jafari, H. M., Kokarovtseva, L., et al. (2012) · doi:10.1109/esscirc.2012.6341340 · Cited by 15 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Ando, H., Takizawa, K., Yoshida, T., Matsushita, K., Hirata, M., & Suzuki, T. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2514522 · Cited by 95 · see citing works
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83 · see citing works
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67 · see citing works
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66 · see citing works
Rozgic, D., Hokhikyan, V., Jiang, W., Akita, I., Basir - Kazeruni, S., Chandrakumar, H., & Markovic, D. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2889040 · Cited by 49 · see citing works
A closed-loop compressive-sensing-based neural recording system
Zhang, J., Mitra, S., Suo, Y., Cheng, A., Xiong, T., Michon, F., Welkenhuysen, M., Kloosterman, F., Chin, P. S., Hsiao, S., et al. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036005 · Cited by 33 · see citing works
- Authors
- Abdelhalim, K., Jafari, H. M., Kokarovtseva, L., Velazquez, J. L. P., & Genov, R.
- Affiliations
- University of Toronto (CA)
- ORCID
- Genov, Roman
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2013-10
- Volume
- 48
- Issue
- 10
- Pages
- 2494-2510
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2091665061
- Cited by
- 124
- References
- 40
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 8 · 2023: 5 · 2022: 12 · 2021: 14 · 2020: 8 · 2019: 7 · 2018: 15 · 2017: 14 · 2016: 18 · 2015: 12 · 2014: 8
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Funders
- CMC Microsystems
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- closed-loop neurostimulation, system-on-chip, FIR filtering, CORDIC processor, seizure detection, epilepsy, CMOS integrated circuit
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review