NIH Stroke Scale Reliability in Ratings from a Large Sample of Clinicians
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objective: The NIH Stroke Scale (NIHSS) is widely used in stroke clinical care and trials. Certification in its use, most commonly through rating of video vignettes, is routinely required. To investigate the reliability of the NIHSS in a representative sample of raters, we examined the results of the most frequently used certification examination. Methods: At the invitation of the National Stroke Association, we analyzed the results of all raters who completed one of two multiple patient videotaped certification examinations from 1998 to 2004. Total scores for each vignette were calculated and ratings were compared based on percentile of responses and modified kappa scores. Results: There were 7,405 unique raters with 38,148 individual NIHSS item responses; median scores for each vignette ranged from 0 to 31. Total NIHSS scores varied widely between raters; scoring for 7 of the 11 patients (64%) had a four or more point difference in NIHSS score from the 5th to 95th percentile. The aphasia (kappa = 0.60) and facial palsy (0.65) items on the test contributed most to the variance in the total NIHSS score. Nurses agreed with the most common response on scoring more frequently than physicians (p < 0.0001). Taking the certification examination multiple times did not improve agreement. Conclusions: In a large diverse sample of clinicians, inter-rater reliability for individual elements of the NIHSS on videotaped vignettes was generally good, but overall scoring was inconsistent and could impact clinical trial results. Whether additional training, modification of examination elements, or clearer definitions for scoring could improve reliability requires further study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Cited by
Jauch, E. C., Saver, J. L., Adams, H. P., Bruno, A., Connors, J. J. (., Demaerschalk, B. M., Khatri, P., McMullan, P. W., Qureshi, A. I., Rosenfield, K., et al. (2013) · Stroke · doi:10.1161/str.0b013e318284056a · Cited by 7,634
Powers, W. J., Rabinstein, A. A., Ackerson, T., Adeoye, O. M., Bambakidis, N. C., Becker, K., Biller, J., Brown, M., Demaerschalk, B. M., Hoh, B., et al. (2019) · Stroke · doi:10.1161/str.0000000000000211 · Cited by 7,468
Powers, W. J., Rabinstein, A. A., Ackerson, T., Adeoye, O. M., Bambakidis, N. C., Becker, K., Biller, J., Brown, M., Demaerschalk, B. M., Hoh, B., et al. (2018) · Stroke · doi:10.1161/str.0000000000000158 · Cited by 5,446
Using the National Institutes of Health Stroke Scale: A Cautionary Tale
Lyden, P. (2017) · Stroke · doi:10.1161/strokeaha.116.015434 · Cited by 484
Reliability of the National Institutes of Health Stroke Scale
McLoughlin, A., Olive, P., & Lightbody, C. E. (2022) · British Journal of Neuroscience Nursing · doi:10.12968/bjnn.2022.18.sup5.s3 · Cited by 383
Metadata
- Authors
- Josephson, S. A., Hills, N. K., & Johnston, S. C.
- Venue
- Cerebrovascular Diseases
- Publisher
- S. Karger AG
- Published
- 2006
- Volume
- 22
- Issue
- 5-6
- Pages
- 389-395
- ISSN
- 1015-9770 (ISSN-L)
- 1421-9786
- OpenAlex
- W1969980996
- Cited by
- 145
- References
- 1
- FWCI
- 4.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NIH Stroke Scale Reliability in Ratings from a Large Sample of Clinicians. https://app.cochat.ai/papers/10.1159/000094857
- The paper
- Josephson, S. A., Hills, N. K., & Johnston, S. C. (2006). NIH Stroke Scale Reliability in Ratings from a Large Sample of Clinicians. Cerebrovascular Diseases. https://doi.org/10.1159/000094857
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.