The DOI matches its Crossref record.
Acoustic plus Electric Speech Processing: Preliminary Results of a Multicenter Clinical Trial of the Iowa/Nucleus Hybrid Implant
Abstract
Aim: This communication details the latest preliminary results from an ongoing multicenter single-subject design clinical trial of the Iowa/Nucleus Hybrid 10-mm cochlear implant. Selection criteria, surgical strategies used for hearing preservation, and the benefits of preserved residual low-frequency hearing, improved word understanding in noise, and music appreciation are described. Patients and Methods: The device has been implanted in 48 individuals with residual low-frequency hearing. Results:Hearing preservation has been accomplished in 46/48 subjects. Acoustic speech perception has also been preserved. Combined acoustic plus electric speech processing has enabled most of this group of volunteers to gain improved word understanding as compared to their preoperative hearing with bilateral hearing aids. A subset of subjects with 12 months or more experience demonstrates CNC word understanding continues to improve more than 24 months after implantation. Improved word understanding in noise is also a benefit of acoustic plus electric speech processing. Conclusions:The improvement of speech in noise and melody recognition is linked to the ability to distinguish fine pitch differences as the result of preserved residual low-frequency acoustic hearing. Both of these measures are very important in real life to the hearing impaired. Preservation of residual low-frequency hearing should be considered when expanding candidate selection criteria for standard cochlear implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Self-citation
Metadata
- Authors
- Gantz, B. J., Turner, C., & Gfeller, K. E.
- Venue
- Audiology and Neurotology
- Publisher
- S. Karger AG
- Published
- 2006
- Volume
- 11
- Issue
- Suppl. 1
- Pages
- 63-68
- ISSN
- 1420-3030 (ISSN-L)
- 1421-9700
- OpenAlex
- W1997698746
- Cited by
- 170
- References
- 0
- FWCI
- 8.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acoustic plus Electric Speech Processing: Preliminary Results of a Multicenter Clinical Trial of the Iowa/Nucleus Hybrid Implant. https://app.cochat.ai/papers/10.1159/000095616
- The paper
- Gantz, B. J., Turner, C., & Gfeller, K. E. (2006). Acoustic plus Electric Speech Processing: Preliminary Results of a Multicenter Clinical Trial of the Iowa/Nucleus Hybrid Implant. Audiology and Neurotology. https://doi.org/10.1159/000095616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.