CoChat

A Comparison of Terahertz Pulsed Imaging with Transmission Microradiography for Depth Measurement of Enamel Demineralisation in vitro

Pickwell, Emma, Wallace, Vincent P., Cole, Bryan E., Ali, Sophia, Longbottom, Christopher, Lynch, Richard J.M., Pepper, Michael · 2007 · Caries Research
Cited by 72

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Terahertz pulsed imaging (TPI) is a relatively new, non-ionising and non-destructive imaging technique for studying hard tissues which does not require tooth section preparation, unlike transmission microradiography (TMR). If TPI can measure the depths of caries/demineralisation lesions accurately the same tooth samples could be reused and remeasured during in vitro and in situ studies on de- and/or remineralisation. The aim of this study was to compare TPI and TMR for measuring the depths of a range of artificially induced bovine enamel demineralised lesions in vitro. Bovine slabs with artificial caries, induced to different levels of demineralisation by two different but standard demineralisation techniques (‘acid gel’ and ‘carbopol’) were measured by TPI and TMR and the readings compared. The set of TPI/TMR measurements obtained on the gel-demineralised slabs showed an extremely high coefficient of determination (r 2 = 0.995). Detailed analysis of the results and theoretical considerations (involving the relationship between refractive index profiling and mineral loss profile) are used to explain the findings and show that for acid gel lesions TPI is measuring demineralisation in the range of 47% of that of TMR depth plus an intercept of 16 µm, with further calculations allowing the TMR depths to be determined to within 5% using TPI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000096105

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Terahertz pulsed imaging and spectroscopy for biomedical and pharmaceutical applications

    Wallace, V. P., Taday, P. F., Fitzgerald, A. J., Woodward, R. M., Cluff, J., Pye, R. J., & Arnone, D. D. (2004) · Faraday Discussions · doi:10.1039/b309357n · Cited by 160 · cited 1×

    “Terahertz pulsed imaging (TPI © ) is a non-destructive, non-ionising imaging modality with uses in medicine [Wallace et al., 2003, 2004; Knobloch et al., 2002; Fitzgerald et al., 2003] and dentistry [Crawley et al., 2003a; Handley et al., 2002].”
    MethodSelf-citation

Show all 1 references

Cited by

See all 72

Metadata

Authors
Pickwell, E., Wallace, V. P., Cole, B. E., Ali, S., Longbottom, C., Lynch, R. J. M., & Pepper, M.
Venue
Caries Research
Publisher
S. Karger AG
Published
2006-12-13
Volume
41
Issue
1
Pages
49-55
ISSN
  • 0008-6568 (ISSN-L)
  • 1421-976X
OpenAlex
W2056319254
Cited by
72
References
1
FWCI
4.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Terahertz Pulsed Imaging with Transmission Microradiography for Depth Measurement of Enamel Demineralisation in vitro. https://app.cochat.ai/papers/10.1159/000096105
The paper
Pickwell, E., Wallace, V. P., Cole, B. E., Ali, S., Longbottom, C., Lynch, R. J. M., & Pepper, M. (2007). A Comparison of Terahertz Pulsed Imaging with Transmission Microradiography for Depth Measurement of Enamel Demineralisation in vitro. Caries Research. https://doi.org/10.1159/000096105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.