Cited by 96Terahertz technology and applicationsOptical Imaging and Spectroscopy TechniquesOptical Coherence Tomography Applications

Improved sample characterization in terahertz reflection imaging and spectroscopy

Open access
Huang, Shengyang, Ashworth, Philip C., Kan, Kanis W., Chen, Yang, Wallace, Vincent P., Zhang, Yuan-ting, Pickwell-MacPherson, Emma·2009·Optics Express

Abstract

For imaging applications involving biological subjects, the strong attenuation of terahertz radiation by water means that terahertz pulsed imaging is most likely to be successfully implemented in a reflection geometry. Many terahertz reflection geometry systems have a window onto which the sample is placed - this window may introduce unwanted reflections which interfere with the reflection of interest from the sample. In this paper we derive a new approach to account for the effects of these reflections and illustrate its success with improved calculations of sample optical properties.

Integrity signals

Registry

Crossref · 10.1364/oe.17.003848

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Huang, S., Ashworth, P. C., Kan, K. W., Chen, Y., Wallace, V. P., Zhang, Y.-T., & Pickwell-MacPherson, E.
Affiliations
  • University of Cambridge (GB)
  • Chinese University of Hong Kong (HK)
  • The University of Western Australia (AU)
Venue
Optics Express
Published
2009-02-26
Volume
17
Issue
5
Pages
3848
ISSN
1094-4087 (ISSN-L)
OpenAlex
W1994677617
Cited by
96
References
20
Citations by year
2026: 2 · 2025: 4 · 2023: 3 · 2022: 9 · 2021: 5 · 2020: 8 · 2019: 6 · 2018: 3 · 2017: 6 · 2016: 11 · 2015: 8 · 2014: 4 · 2013: 6 · 2012: 5
FWCI
5.55
Type
journal article
Language
en
Open access
Locations
  • Optics Express (publishedVersion)
  • PubMed (publishedVersion)
  • UWA Profiles and Research Repository (UWA) (submittedVersion)
  • Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
Funders
Hong Kong Government
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
Keywords
terahertz reflection imaging, terahertz spectroscopy, sample characterization, water attenuation, biological specimen, reflection geometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review