The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Two-Photon Microscopy of Vital Murine Elastic and Muscular Arteries
Abstract
Understanding vascular pathologies requires insight in the structure and function, and, hence, an imaging technique combining subcellular resolution, large penetration depth, and optical sectioning. We evaluated the applicability of two-photon laser-scanning microscopy (TPLSM) in large elastic and small muscular arteries under physiological conditions. Elastic (carotid) and muscular (uterine, mesenteric) arteries of C57BL/6 mice were mounted in a perfusion chamber. TPLSM was used to assess the viability of arteries and to visualize the structural components elastin, collagen, nuclei, and endothelial glycocalyx (EG). Functionality was determined using diameter changes in response to noradrenaline and acetylcholine. Viability and functionality were maintained up to 4 h, enabling the assessment of structure-function relationships. Structural vessel wall components differed between elastic and muscular arteries: size (1.3 vs. 2.1 µm) and density (0.045 vs. 0.57 µm–2) of internal elastic lamina fenestrae, smooth muscle cell density (3.50 vs. 1.53 µm–3), number of elastic laminae (3 vs. 2), and adventitial collagen structure (tortuous vs. straight). EG in elastic arteries was 4.5 µm thick, covering 66% of the endothelial surface. TPLSM enables visualization and quantification of subcellular structures in vital and functional elastic and muscular murine arteries, allowing unraveling of structure-function relationships in healthy and diseased arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Cited by
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
Self-citationRezakhaniha, R., Agianniotis, A., Schrauwen, J. T. C., Griffa, A., Sage, D., Bouten, C. V. C., van de Vosse, F. N., Unser, M., & Stergiopulos, N. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0325-z · Cited by 1,096
Glycocalyx and sepsis-induced alterations in vascular permeability
Chelazzi, C., Villa, G., Mancinelli, P., De Gaudio, A. R., & Adembri, C. (2015) · Critical Care · doi:10.1186/s13054-015-0741-z · Cited by 389
Weber, C., Meiler, S., Döring, Y., Koch, M., Drechsler, M., Megens, R. T. A., Rowinska, Z., Bidzhekov, K., Fecher, C., Ribechini, E., et al. (2011) · Journal of Clinical Investigation · doi:10.1172/jci44925 · Cited by 273
Self-citationLoss of the Endothelial Glycocalyx Links Albuminuria and Vascular Dysfunction
Salmon, A. H. J., Ferguson, J. K., Burford, J. L., Gevorgyan, H., Nakano, D., Harper, S. J., Bates, D. O., & Peti-Peterdi, J. (2012) · Journal of the American Society of Nephrology · doi:10.1681/asn.2012010017 · Cited by 267
Metadata
- Authors
- Megens, R. T. A., Reitsma, S., Schiffers, P. H. M., Hilgers, R. H. P., De Mey, J. G. R., Slaaf, D. W., oude Egbrink, M. G. A., & van Zandvoort, M. A. M. J.
- Venue
- Journal of Vascular Research
- Publisher
- S. Karger AG
- Published
- 2006-12-28
- Volume
- 44
- Issue
- 2
- Pages
- 87-98
- ISSN
- 1018-1172 (ISSN-L)
- 1423-0135
- OpenAlex
- W1991376496
- Cited by
- 196
- References
- 1
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.