Paraplegia: Prolonged Closed-Loop Standing with Implanted Nucleus FES-22 Stimulator and Andrews' Foot-Ankle Orthosis
The DOI matches its Crossref record.
Abstract
Our object is to develop a reliable, implantable and closed-loop functional electrical stimulator (FES) hybrid system for safe prolonged standing in paraplegic individuals. Open-loop FES systems rapidly induce muscle fatigue that limits paraplegic standing to less than 20 and typically 10 min. Since December 1991, a paraplegic male (CS: 23 years old, T10 level, Asia: A) has been implanted with the first Nucleus FES-22 channel stimulating system (Cochlear Ltd., Lane Cove, N.S.W., Australia). Epineural platinum disc electrodes (2.5 mm) were placed on branches of the femoral, gluteal and sciatic nerves, which can be activated to produce controlled lower extremity movements for exercise and standing. No medical complications have occurred during these 5 1/2 years of implantation. The ankles are stabilized with Andrews' ankle-foot braces, the knees are free to flex. With bilateral knee goniometers fitted to sense a 10 degrees angle flexion, this hybrid closed-loop stimulation system allows the patient to achieve safe uninterrupted standing for over 60 min. The stimulator has needed to be activated 'on' for 8% (range: 3-17%) of the standing times, preventing muscle fatigue, with little or no changes found in the vital signs. The patient can manipulate and transfer objects at arm length up to 2.2 kg with good stability. New, less obstrusive sensors are currently being tested for a safer and more reliable closed-loop system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Exercise Recommendations for Individuals with Spinal Cord Injury
Jacobs, P. L., & Nash, M. S. (2004) · Sports Medicine · doi:10.2165/00007256-200434110-00003 · Cited by 453
Exercise as a health-promoting activity following spinal cord injury
Nash, M. S. (2005) · Journal of Neurologic Physical Therapy · doi:10.1097/01.npt.0000282514.94093.c6 · Cited by 180
Control of urinary bladder function with devices: successes and failures
Gaunt, R. A., & Prochazka, A. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(05)52011-9 · Cited by 105
Bijak, M., Mayr, W., Girsch, W., Lanmüller, H., Unger, E., Stöhr, H., Thoma, H., & Plenk, H. (2001) · Artificial Organs · doi:10.1046/j.1525-1594.2001.025006467.x · Cited by 8
Metadata
- Authors
- Davis, R., Houdayer, T., Andrews, B., Emmons, S., & Patrick, J.
- Venue
- Stereotactic and Functional Neurosurgery
- Publisher
- S. Karger AG
- Published
- 1997
- Volume
- 69
- Issue
- 1-4
- Pages
- 281-287
- ISSN
- 1011-6125 (ISSN-L)
- 1423-0372
- OpenAlex
- W1965742895
- Cited by
- 46
- References
- 0
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.