The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Use of Tissue Oxygenation Index and Fractional Tissue Oxygen Extraction as Non-Invasive Parameters for Cerebral Oxygenation
Abstract
Objective: To evaluate the relation between cerebral tissue oxygenation index (TOI), measured with spatially resolved spectroscopy (SRS), and the different oxygenation parameters. To evaluate the relation between a new parameter named fractional tissue oxygen extraction (FTOE) and the cerebral fractional oxygen extraction (FOE). Methods: Six newborn piglets were measured at 33, 35, and 37°C and in hypocapnia. Mean arterial blood pressure (MABP), haemoglobin (Hb), peripheral oxygen saturation (S a O 2) and P a CO 2 were measured at each step. Cerebral blood flow (CBF) was measured by injection of coloured microspheres into the left atrium. Jugular bulb oxygen saturation (JVS), cerebral arterial and venous oxygen content (C a O 2 and C v O 2) and FOE were calculated. TOI of the brain was calculated and FTOE was introduced as (S a O 2 – TOI)/S a O 2. The correlation was calculated with an ANCOVA test. Results: There was a positive correlation (R = 0.4 and p = 0.011) between TOI and JVS. No correlation was found with CBF, MABP or Hb. There was a positive correlation between P a CO 2 and cerebral TOI (R = 0.24 and p = 0.03). FTOE correlated well with FOE (R = 0.4 and p = 0.016) and there was a negative correlation between FTOE and P a CO 2 (R = 0.24, p = 0.03). Conclusion: The measurement of TOI and FTOE by SRS correlated well with the cerebral venous saturation and FOE, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101995 · Cited by 1,827 · cited 1×
“who found a decrease in CBF after applications of hot packs to both thighs for 10 min.Hypocapnia causes a vasoconstriction in the cerebral circulation [”
Background
Cited by
Monitoring Neonatal Regional Cerebral Oxygen Saturation in Clinical Practice: Value and Pitfalls
van Bel, F., Lemmers, P., & Naulaers, G. (2008) · Neonatology · doi:10.1159/000151642 · Cited by 258
Self-citationAlderliesten, T., Lemmers, P. M. A., Smarius, J. J. M., van de Vosse, R. E., Baerts, W., & van Bel, F. (2013) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2012.09.038 · Cited by 254
Alderliesten, T., Dix, L., Baerts, W., Caicedo, A., van Huffel, S., Naulaers, G., Groenendaal, F., van Bel, F., & Lemmers, P. (2016) · Pediatric Research · doi:10.1038/pr.2015.186 · Cited by 199
Self-citation
Metadata
- Authors
- Naulaers, G., Meyns, B., Miserez, M., Leunens, V., Van Huffel, S., Casaer, P., Weindling, M., & Devlieger, H.
- Venue
- Neonatology
- Publisher
- S. Karger AG
- Published
- 2007
- Volume
- 92
- Issue
- 2
- Pages
- 120-126
- ISSN
- 1661-7800 (ISSN-L)
- 1661-7819
- OpenAlex
- W2069644666
- Cited by
- 218
- References
- 1
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Tissue Oxygenation Index and Fractional Tissue Oxygen Extraction as Non-Invasive Parameters for Cerebral Oxygenation. https://app.cochat.ai/papers/10.1159/000101063
- The paper
- Naulaers, G., Meyns, B., Miserez, M., Leunens, V., Van Huffel, S., Casaer, P., Weindling, M., & Devlieger, H. (2007). Use of Tissue Oxygenation Index and Fractional Tissue Oxygen Extraction as Non-Invasive Parameters for Cerebral Oxygenation. Neonatology. https://doi.org/10.1159/000101063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.