Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record.

Quantification of Atheromatous Stenosis in the Extracranial Internal Carotid Artery

de Bray, J.M., Glatt, B.·1995·Cerebrovascular Diseases

Abstract

An international consensus meeting to determine criteria for the quantification of stenosis of the extracranial internal carotid artery was held in Paris on December 2 and 3, 1994. A review of the literature and expert analysis of validity and reproducibility led to the following recommendations: Intra-arterial X-ray angiography: At present, two main methods of quantification are being evaluated, the distal and the local method, the former being the better validated. The latter method, on the other hand, is better able to represent moderate lesions at the level of the carotid bulb. Therefore, it is suggested that a ratio between the stenosis and the common carotid artery should also be established. X-ray angiography prior to carotid endarterectomy can be avoided if ultrasound and MR angiography concur in identifying severe stenosis provided that intracranial vessels are without relevant disease. Ultrasound Doppler duplex methods can quantify the degree of extracranial carotid artery stenosis in terms of both diameter reduction according to the criteria established by recent surgical studies (NASCET – distal degree of stenosis – and ECST – local degree of stenosis – as well as residual area in cross-sections. The latter is more suitable since hemodynamic effect, local increase of velocity, and pressure drop are taken into consideration. Technical requirements (carrier frequency 4–5 MHz, Doppler angle inferior to 60°, sample volume ≧5 mm) call for a combination of three validated criteria. Maximum Doppler shift/flow velocities measured at the narrowest point of the stenosis and the degree of poststenotic flow disturbances should be examined. In systole, a value of 4 kHz (120 cm/s) (f0 = 4 MHz), identifies most stenoses >50% in local diameter reduction and as in end-diastole, a value of 4.5 kHz (135 cm/s) identifies stenoses of >80%. Carotid ratio: The systolic velocity ratio should be recorded between the site of the stenosis and the common carotid artery obtained 3 cm below the bifurcation. This limits the influence of general hemodynamic factors unrelated to the stenosis such as the cardiac output. A threshold value of >1.5 determines stenoses of >50% and a threshold value of >4, stenoses of >70%. Area ratio: The ratio between the total arterial lumen in cross-section and the minimal residual lumen should be determined by echotomography and additional color Doppler flow imaging. In addition there are indirect criteria, such as asymmetry of pulsatility of the common carotid artery and middle cerebral artery signals as well as inverted flow of the ophthalmic artery which distinguish moderate from high-degree stenoses (>80% diameter reduction). Magnetic resonance angiography (MRA): With this method, a diameter ratio using the distal degree of stenosis is recommended with data obtained from transverse source images in addition to transverse T1 sequences. MRA is a complement to ultrasonic methods, particularly in cases of calcified stenoses and for the analysis of intracranial vessels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000107895

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 215

Metadata

Authors
de Bray, J. M., & Glatt, B.
Venue
Cerebrovascular Diseases
Publisher
S. Karger AG
Published
1995
Volume
5
Issue
6
Pages
414-426
ISSN
  • 1015-9770 (ISSN-L)
  • 1421-9786
OpenAlex
W2095434842
Cited by
215
References
0
FWCI
6.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of Atheromatous Stenosis in the Extracranial Internal Carotid Artery. https://app.cochat.ai/papers/10.1159/000107895
The paper
de Bray, J. M., & Glatt, B. (1995). Quantification of Atheromatous Stenosis in the Extracranial Internal Carotid Artery. Cerebrovascular Diseases. https://doi.org/10.1159/000107895

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.