The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Assessment of Brain Shift Related to Deep Brain Stimulation Surgery
Abstract
Deep brain stimulation (DBS) surgery can significantly improve the quality of life for patients suffering from movement disorders, but the success of the procedure depends on the implantation accuracy of the DBS electrode array. Pre-operative surgical planning and navigation are based on the assumption that the brain tissue is rigid between the time of the acquisition of the pre-operative image set and the time of surgery. A shift of deep brain structures by only a few millimeters can potentially increase the number of required microelectrode and/or macroelectrode tracks and decrease implantation accuracy. We studied 25 subjects that underwent DBS surgery and analyzed brain shift between pre-operative and post-operative 3D MRI scans. Brain shift of up to 4 mm was observed in deep brain structures. On average, the recorded shift was in the direction of gravity, with deeper structures experiencing smaller shift than more superficial structures. The main conclusion of the study is that the brain shift is comparable to the size of the targets in deep brain stimulation surgery and should not be ignored. Techniques that minimize the amount of brain shift may therefore lead to increased accuracy of DBS lead implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Cited by
Bot, M., van den Munckhof, P., Bakay, R., Stebbins, G., & Verhagen Metman, L. (2017) · Stereotactic and Functional Neurosurgery · doi:10.1159/000475672 · Cited by 671
Val-Laillet, D., Aarts, E., Weber, B., Ferrari, M., Quaresima, V., Stoeckel, L. E., Alonso-Alonso, M., Audette, M., Malbert, C. H., & Stice, E. (2015) · NeuroImage: Clinical · doi:10.1016/j.nicl.2015.03.016 · Cited by 442
Metadata
- Authors
- Khan, M. F., Mewes, K., Gross, R. E., & Škrinjar, O.
- Venue
- Stereotactic and Functional Neurosurgery
- Publisher
- S. Karger AG
- Published
- 2007-09-18
- Volume
- 86
- Issue
- 1
- Pages
- 44-53
- ISSN
- 1011-6125 (ISSN-L)
- 1423-0372
- OpenAlex
- W2086553752
- Cited by
- 170
- References
- 1
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Brain Shift Related to Deep Brain Stimulation Surgery. https://app.cochat.ai/papers/10.1159/000108588
- The paper
- Khan, M. F., Mewes, K., Gross, R. E., & Škrinjar, O. (2008). Assessment of Brain Shift Related to Deep Brain Stimulation Surgery. Stereotactic and Functional Neurosurgery. https://doi.org/10.1159/000108588
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.