The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dry Powder Inhalers: Which Factors Determine the Frequency of Handling Errors?
Abstract
Background: Dry powder inhalers are often used ineffectively, resulting in a poor level of disease control. Objectives: To determine how often essential mistakes are made in the use of Aerolizer®, Discus®, HandiHaler® and Turbuhaler® and to study the effects of age, severity of airflow obstruction and previous training in inhalational technique by medical personnel on the error rate. Methods: Two hundred and twenty-four newly referred outpatients (age 55.1 ± 20 years) were asked how they had been acquainted with the inhaler and to demonstrate their inhalational technique. Results: The inhaler-specific error rates were as follows: Aerolizer 9.1%, Discus 26.7%, HandiHaler 53.1% and Turbuhaler 34.9%. Compared to Aerolizer, the odds ratio of an ineffective inhalation was higher for HandiHaler (9.82, p < 0.01) and Turbuhaler (4.84, p < 0.05). The error rate increased with age and with the severity of airway obstruction (p < 0.01). When training had been given as opposed to no training, the odds ratio of ineffective inhalation was 0.22 (p < 0.01). If Turbuhaler is used, the estimated risks range from 9.8% in an 18-year-old patient with normal lung function and previous training to 83.2% in an 80-year-old patient with moderate or severe obstruction who had not received any training. Conclusions: Dry powder inhalers are useful in the management of younger patients with normal lung function or mild airway obstruction. In older patients with advanced chronic obstructive pulmonary disease, the risk of ineffective inhalation remains high despite training in inhalational technique. A metered-dose inhaler with a spacer might be a valuable treatment alternative in a substantial proportion of these patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fitzmaurice, G. M., Laird, N. M., & Ware, J. H. (2011) · Wiley Series in Probability and Statistics · doi:10.1002/9781119513469 · Cited by 4,639
Cited by
Systematic Review of Errors in Inhaler Use
Sanchis, J., Gich, I., & Pedersen, S. (2016) · CHEST · doi:10.1016/j.chest.2016.03.041 · Cited by 538
Critical inhaler errors in asthma and COPD: a systematic review of impact on health outcomes
Usmani, O. S., Lavorini, F., Marshall, J., Dunlop, W. C. N., Heron, L., Farrington, E., & Dekhuijzen, R. (2018) · Respiratory Research · doi:10.1186/s12931-017-0710-y · Cited by 402
Gibson, P. G., McDonald, V. M., & Marks, G. B. (2010) · The Lancet · doi:10.1016/s0140-6736(10)61087-2 · Cited by 394
Inhaler competence in asthma: Common errors, barriers to use and recommended solutions
Price, D., Bosnic-Anticevich, S., Briggs, A., Chrystyn, H., Rand, C., Scheuch, G., & Bousquet, J. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2012.09.017 · Cited by 358
Drug Delivery to the lungs: Challenges and Opportunities
Newman, S. P. (2017) · Therapeutic Delivery · doi:10.4155/tde-2017-0037 · Cited by 328
Metadata
- Authors
- Wieshammer, S., & Dreyhaupt, J.
- Venue
- Respiration
- Publisher
- S. Karger AG
- Published
- 2007-10-02
- Volume
- 75
- Issue
- 1
- Pages
- 18-25
- ISSN
- 0025-7931 (ISSN-L)
- 1423-0356
- OpenAlex
- W1964860794
- Cited by
- 169
- References
- 1
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dry Powder Inhalers: Which Factors Determine the Frequency of Handling Errors? https://app.cochat.ai/papers/10.1159/000109374
- The paper
- Wieshammer, S., & Dreyhaupt, J. (2008). Dry Powder Inhalers: Which Factors Determine the Frequency of Handling Errors? Respiration. https://doi.org/10.1159/000109374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.