Spectral Analysis of All-Night Sleep EEG in Healthy Adults
The DOI matches its Crossref record.
Abstract
Power and coherence spectra were computed from all-night sleep EEG records in 6 healthy adult subjects. Derivations were from F3, F4, P3, P4, O1, O2, T3, and T4 to the vertex (Cz). Records were conventionally scored into sleep stages. Average power per sleep stage was maximal at frequencies 0.4-6 c/s in stage 4, at 6-10 c/s in either stage 3 or stage 4, at 12-14 c/s in stage 2 and at 14-30 c/s in stage 1. The average power range from highest values in the lowest frequency band to lowest values in the highest frequency band showed marked differences between sleep stages: It was lowest (12-14 dB) in stage 1, followed by stage 2 (20-22 dB), and stage 3 (16-28 dB), and largest in stage 4 (29-32 dB). REM sleep (15-16 sB) was between stage 1 and 2. The waking state showed an average power range of 11-15 dB. Alpha power at 8-10 c/s in occipital and parietal leads was remarkably constant during sleep, i.e. independent of sleep stage. Coherence showed maximal values at 2-8 c/s in REM sleep, at 8-12 c/s in stage 4, at 12-17 c/s in either stage 3 or 4, and at 17-30 c/s again in stage REM. There was significant coherence increase at 2-8 and 17-30 c/s from NREM to REM sleep, most pronounced between parietal to vertex derivations. Overall coherence between both occipital-to-vertex, or between occipital and parietal-to-vertex derivations, was essentially higher than in the other derivations. The results, essentially, give a comprehensive phenomenology of the dynamic spectral structure of all-night sleep EEG. They suggest that the different brain states during sleep (e.g. stage 1 NREM vs. REM) which are associated with different functions (e.g. hypnagogic hallucinations vs. dreams) differ in EEG spectral parameters if coherence is considered. Likewise, they suggest that studies of automatic sleep staging based exclusively on EEG spectral parameters appear promising.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sleep spindles: mechanisms and functions
Fernandez, L. M. J., & Lüthi, A. (2020) · Physiological Reviews · doi:10.1152/physrev.00042.2018 · Cited by 716
The reinterpretation of dreams: An evolutionary hypothesis of the function of dreaming
Revonsuo, A. (2000) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00004015 · Cited by 676
Prediction of electroencephalographic spectra from neurophysiology
Robinson, P. A., Rennie, C. J., Wright, J. J., Bahramali, H., Gordon, E., & Rowe, D. L. (2001) · Physical Review E · doi:10.1103/physreve.63.021903 · Cited by 362
Bilateral eye movements enhance the retrieval of episodic memories.
Christman, S. D., Garvey, K. J., Propper, R. E., & Phaneuf, K. A. (2003) · Neuropsychology · doi:10.1037/0894-4105.17.2.221 · Cited by 255
Cantero, J. L., Atienza, M., & Salas, R. M. (2002) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(01)00289-1 · Cited by 222
Coherence analysis of the human sleep electroencephalogram
Achermann, P., & Borbély, A. A. (1998) · Neuroscience · doi:10.1016/s0306-4522(97)00692-1 · Cited by 194
Sleep EEG, depression and gender
Armitage, R., & Hoffmann, R. F. (2001) · Sleep Medicine Reviews · doi:10.1053/smrv.2000.0144 · Cited by 170
Topographic analysis of coherence and propagation of EEG activity during sleep and wakefulness
Kamiński, M., Blinowska, K., & Szelenberger, W. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95721-5 · Cited by 170
Lateral coherence of the electrocorticogram: a new measure of brain synchrony
Bullock, T. H., & McClune, M. C. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90258-7 · Cited by 164
Lehmann, D., Faber, P. L., Tei, S., Pascual-Marqui, R. D., Milz, P., & Kochi, K. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.042 · Cited by 150
“…successful task performance (e.g. Anokhin et al., 1999; Beaumont et al., 1978; Holz et al., 2008; Okuhata et al., 2009;Weiss et al., 2005), but also, increased coherence has been reported during sleep compared towakefulness (e.g. Dumermuth et al., 1983; Kaminski et al., 1997; Nielsen et al., 1990).”
BackgroundMethodInfluentialSelf-citationTemporal evolution of coherence and power in the human sleep electroencephalogram
Achermann, P., & BorbÉly, A. (1998) · Journal of Sleep Research · doi:10.1046/j.1365-2869.7.s1.6.x · Cited by 89
Reduced alpha power associated with the recall of mentation from Stage 2 and Stage REM sleep
Esposito, M. J., Nielsen, T. A., & Paquette, T. (2004) · Psychophysiology · doi:10.1111/j.1469-8986.00143.x · Cited by 86
“For example, Alpha power is reduced during recovery sleep following selective REM sleep deprivation (Brunner, Dijk, & Borbely, 1993; Endo et al., 1998), when REM sleep pressure is high and sleep mentation is more vivid (Weinstein, Schwartz, & Ellman, 1991). Endo et al. (1998) even propose that Alpha power may be a bio…”
BackgroundAlpha reactivity to first names differs in subjects with high and low dream recall frequency
Ruby, P., Blochet, C., Eichenlaub, J.-B., Bertrand, O., Morlet, D., & Bidet-Caulet, A. (2013) · Frontiers in Psychology · doi:10.3389/fpsyg.2013.00419 · Cited by 44
Rhinal–hippocampal EEG coherence is reduced during human sleep
Fell, J., Staedtgen, M., Burr, W., Kockelmann, E., Helmstaedter, C., Schaller, C., Elger, C. E., & Fernández, G. (2003) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2003.02934.x · Cited by 38
Metadata
- Authors
- Dumermuth, G., Lange, B., Lehmann, D., Meier, C. A., Dinkelmann, R., & Molinari, L.
- Venue
- European Neurology
- Publisher
- S. Karger AG
- Published
- 1983
- Volume
- 22
- Issue
- 5
- Pages
- 322-339
- ISSN
- 0014-3022 (ISSN-L)
- 1421-9913
- OpenAlex
- W2056264547
- Cited by
- 62
- References
- 0
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.