The DOI matches its Crossref record.
Functional Morphology of Force Transmission in Skeletal Muscle
Abstract
The work done by the contractile proteins of muscle in accelerating, decelerating, or maintaining the positions of skeletal elements requires the efficient transmission of tension across the surface membranes of the fibers. The most widely studied sites of tension transmission are the ends of muscle fibers where they contact either connective or epithelial tissues. In most animals, regardless of phylum, muscle fiber ends are characteristically folded, producing a junctional interface that significantly reduces the absolute value of stress applied to the cell membrane, insures that the principle stress vector at the cell membrane is shear rather than tension, and minimizes stress concentrations. The morphological and molecular similarities of muscle-tendon junctions (MTJs) in different animals suggest that the problem of creating a strong adhesive joint between a muscle fiber and a tissue of dissimilar physical properties is essentially the same for all muscles, and that the solution arose early in evolution. In addition to those muscle fiber ends that occur where fibers contact dissimilar tissues, there are intramuscular fiber terminations that consist either of folded cell-cell junctions similar to the fasciae adherentes of cardiac muscle, or of gradually tapering fiber ends. Both sorts of intramuscular ends occur in those vertebrate muscles in which the individual muscle fibers are too short to reach from the tendon of origin to the tendon of insertion. In series-fibered muscles in which the fiber ends are tapered, tension is transmitted from contractile proteins to endomysial collagen fibrils across the fiber membranes. The endomysium of such muscles is an essential series-elastic element. The existing evidence suggests that tension transmission is a general property of muscle cell surfaces, and that specific junctional morphologies are the results of dynamic interactions between muscle cells and the tissues to which they adhere.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Role of Extracellular Matrix in Adaptation of Tendon and Skeletal Muscle to Mechanical Loading
KJÆR, M. (2004) · Physiological Reviews · doi:10.1152/physrev.00031.2003 · Cited by 1,586
Aagaard, P., Andersen, J. L., Dyhre‐Poulsen, P., Leffers, A., Wagner, A., Magnusson, S. P., Halkjær‐Kristensen, J., & Simonsen, E. B. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.t01-1-00613.x · Cited by 733
A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii
Blemker, S. S., Pinsky, P. M., & Delp, S. L. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.04.009 · Cited by 443
Arnold, E. M., Hamner, S. R., Seth, A., Millard, M., & Delp, S. L. (2013) · Journal of Experimental Biology · doi:10.1242/jeb.075697 · Cited by 261
Metadata
- Authors
- Trotter, J. A.
- Venue
- Cells Tissues Organs
- Publisher
- S. Karger AG
- Published
- 1993
- Volume
- 146
- Issue
- 4
- Pages
- 205-222
- ISSN
- 1422-6405 (ISSN-L)
- 1422-6421
- OpenAlex
- W2080149386
- Cited by
- 171
- References
- 0
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional Morphology of Force Transmission in Skeletal Muscle. https://app.cochat.ai/papers/10.1159/000147459
- The paper
- Trotter, J. A. (1993). Functional Morphology of Force Transmission in Skeletal Muscle. Cells Tissues Organs. https://doi.org/10.1159/000147459
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.