CoChat

Validity and Reproducibility of ICDAS II in Primary Teeth

Shoaib, L., Deery, C., Ricketts, D.N.J., Nugent, Z.J. · 2009 · Caries Research
Cited by 146

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The aim of this in vitro study was to assess the validity and reproducibility of the ICDAS II (International Caries Detection and Assessment System) criteria in primary teeth. Three trained examiners independently examined 112 extracted primary molars, ranging from clinically sound to cavitated, set up in groups of 4 to mimic their anatomical positions. The most advanced caries on the occlusal and approximal surfaces was recorded. Subsequently the teeth were serially sectioned and histological validation was undertaken using the Downer and Ekstrand-Ricketts-Kidd (ERK) scoring systems. For occlusal surfaces at the D 1/ERK 1 threshold, the mean specificity was 90.0%, with a sensitivity of 75.4%. For approximal surfaces, the specificity and sensitivity were 85.4 and 66.4%, respectively. For occlusal surfaces at ICDAS code ≥3 (ERK 3 threshold), the mean specificity and sensitivity were 87.0 and 78.1%, respectively. For approximal surfaces, the equivalent values were 90.6 and 75.3%. At the D 3 threshold for occlusal surfaces, the mean specificity and sensitivity were 92.8 and 63.1%, and for approximal surfaces 94.2 and 58.3%, respectively. Mean intraexaminer reproducibility (Cohen’s kappa) ranged from 0.78 to 0.81 at the ICDAS code ≥1 cut-off and at the ICDAS code ≥3 cut-off from 0.74 to 0.76. Interexaminer reproducibility was lower, ranging from 0.68 to 0.70 at the ICDAS code ≥1 cut-off and from 0.66 to 0.73 at the ICDAS code ≥3 cut-off. In conclusion, the validity and reproducibility of the ICDAS II criteria were acceptable when applied to primary molar teeth.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000258551

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 16

  1. 10.1046%2Fj.1365-263x.2000.00189.x · doi:10.1046/j.1365-263x.2000.00189.x
  2. 10.1038%2Fsj.bdj.4800998a · doi:10.1038/sj.bdj.4800998a
  3. 10.1111%2Fj.1752-7325.2002.tb03446.x · DOI · Paper page
  4. 10.1177%2F154405910208100912 · DOI · Paper page
  5. 10.1159%2F000016563 · DOI
  6. 10.1159%2F000260160 · DOI
  7. 10.1111%2Fj.1365-263X.2006.00807.x · doi:10.1111/j.1365-263x.2006.00807.x
  8. 10.1159%2F000262404 · DOI · Paper page
  9. 10.1159%2F000016460 · DOI · Paper page
  10. 10.1034%2Fj.1600-0528.2000.280107.x · DOI
  11. 10.1177%2F154405910408301S12 · DOI · Paper page
  12. 10.1159%2F000113160 · DOI · Paper page
  13. 10.1038%2Fsj.bdj.4808172 · DOI
  14. 10.1159%2F000068226 · DOI · Paper page
  15. 10.1159%2F000189705 · DOI
  16. 10.1159%2F000073396 · DOI

Cited by

Metadata

Authors
Shoaib, L., Deery, C., Ricketts, D. N. J., & Nugent, Z. J.
Venue
Caries Research
Publisher
S. Karger AG
Published
2009
Volume
43
Issue
6
Pages
442-448
ISSN
  • 0008-6568 (ISSN-L)
  • 1421-976X
OpenAlex
W2068355596
Cited by
146
References
2
FWCI
8.61
Type
journal article
Language
en
Open access
closed
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.