The DOI matches its Crossref record.
Plasma Cortisol and Adrenocorticotropin in Appropriate and Small for Gestational Age Fetuses
Abstract
Plasma cortisol and adrenocorticotropin (ACTH) were measured in fetal blood samples obtained by cordocentesis from 61 appropriate for gestational age (AGA) and in 41 small for gestational age (SGA) fetuses at 18–38 weeks gestation. Fetal plasma cortisol (mean 74 nmol/l) did not change but plasma ACTH increased between 18 and 36 weeks gestation and the two were not significantly correlated. Plasma cortisol in cord blood samples after vaginal delivery at term (mean 305 nmol/l) was higher than in samples at elective cesarean section (mean 151 nmol/l), and there was a significant correlation between fetal and maternal levels. The findings suggest that in human fetuses a late gestational rise in plasma cortisol may not be necessary for organ maturation and that the high fetal plasma cortisol in spontaneous labor at term is probably the result rather than the cause of labor. In SGA fetuses, plasma cortisol was higher and ACTH lower than in AGA fetuses, and plasma cortisol was inversely correlated to fetal hypoglycemia, suggesting that in the chronically hypoglycemic SGA fetus the fetal pituitary is under negative inhibition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Developmental Origins of the Metabolic Syndrome: Prediction, Plasticity, and Programming
Mcmillen, I. C., & Robinson, J. S. (2005) · Physiological Reviews · doi:10.1152/physrev.00053.2003 · Cited by 1,910
Fetal plasma cortisol and β-endorphin response to intrauterine needling
Giannakoulopoulos, X., Glover, V, Sepulveda, W., Kourtis, P., & Fisk, N. M. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91279-3 · Cited by 295
SHEEP MODELS OF INTRAUTERINE GROWTH RESTRICTION: FETAL ADAPTATIONS AND CONSEQUENCES
Morrison, J. L. (2008) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2008.04975.x · Cited by 289
Restriction of placental function alters heart development in the sheep fetus
Morrison, J. L., Botting, K. J., Dyer, J. L., Williams, S. J., Thornburg, K. L., & McMillen, I. C. (2007) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00798.2006 · Cited by 184
Intrauterine growth restriction delays surfactant protein maturation in the sheep fetus
Orgeig, S., Crittenden, T. A., Marchant, C., McMillen, I. C., & Morrison, J. L. (2010) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00226.2009 · Cited by 113
Metadata
- Authors
- Economides, D. L., Nicolaides, K. H., Linton, E. A., Perry, L. A., & Chard, T.
- Venue
- Fetal Diagnosis and Therapy
- Publisher
- S. Karger AG
- Published
- 1988
- Volume
- 3
- Issue
- 3
- Pages
- 158-164
- ISSN
- 1015-3837 (ISSN-L)
- 1421-9964
- OpenAlex
- W2044669700
- Cited by
- 179
- References
- 0
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasma Cortisol and Adrenocorticotropin in Appropriate and Small for Gestational Age Fetuses. https://app.cochat.ai/papers/10.1159/000263348
- The paper
- Economides, D. L., Nicolaides, K. H., Linton, E. A., Perry, L. A., & Chard, T. (1988). Plasma Cortisol and Adrenocorticotropin in Appropriate and Small for Gestational Age Fetuses. Fetal Diagnosis and Therapy. https://doi.org/10.1159/000263348
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.