Computer-Assisted Sleep Classification according to the Standard of the American Academy of Sleep Medicine: Validation Study of the AASM Version of the Somnolyzer 24 × 7
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: In 2007, the AASM Manual for the Scoring of Sleep and Associated Events was published by the American Academy of Sleep Medicine (AASM). Concerning the visual classification of sleep stages, these new rules are intended to replace the rules by Rechtschaffen and Kales (R&K). Methods: We adapted the automatic R&K sleep scoring system Somnolyzer 24 × 7 to comply with the AASM rules and subsequently performed a validation study based on 72 polysomnographies from the Siesta database (56 healthy subjects, 16 patients, 38 females, 34 males, aged 21–86 years). Scorings according to the AASM rules were performed manually by experienced sleep scorers and semi-automatically by the AASM version of the Somnolyzer. Manual scorings and Somnolyzer reviews were performed independently by at least 2 out of 8 experts from 4 sleep centers. Results: In the quality control process, sleep experts corrected 4.8 and 3.7% of the automatically assigned epochs, resulting in a reliability between 2 Somnolyzer-assisted scorings of 99% (Cohen’s kappa: 0.99). In contrast, the reliability between the 2 manual scorings was 82% (kappa: 0.76). The agreement between the 2 Somnolyzer-assisted and the 2 visual scorings was between 81% (kappa: 0.75) and 82% (kappa: 0.76). Conclusion: The AASM version of the Somnolyzer revealed an agreement between semi-automated and human expert scoring comparable to that published for the R&K version with a validity comparable to that of human experts, but with a reliability close to 1, thereby reducing interrater variability as well as scoring time to a minimum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DANKER‐HOPFE, H., ANDERER, P., ZEITLHOFER, J., BOECK, M., DORN, H., GRUBER, G., HELLER, E., LORETZ, E., MOSER, D., PARAPATICS, S., et al. (2009) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2008.00700.x · Cited by 417
Self-citation
Cited by
U-Sleep: resilient high-frequency sleep staging
Perslev, M., Darkner, S., Kempfner, L., Nikolic, M., Jennum, P. J., & Igel, C. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00440-5 · Cited by 362
Expert-level sleep scoring with deep neural networks
Biswal, S., Sun, H., Goparaju, B., Westover, M. B., Sun, J., & Bianchi, M. T. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy131 · Cited by 290
Automated sleep scoring: A review of the latest approaches
Fiorillo, L., Puiatti, A., Papandrea, M., Ratti, P.-L., Favaro, P., Roth, C., Bargiotas, P., Bassetti, C. L., & Faraci, F. D. (2019) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2019.07.007 · Cited by 284
Sleep enhances exposure therapy
Kleim, B., Wilhelm, F. H., Temp, L., Margraf, J., Wiederhold, B. K., & Rasch, B. (2014) · Psychological Medicine · doi:10.1017/s0033291713001748 · Cited by 113
Deep Learning and Insomnia: Assisting Clinicians With Their Diagnosis
Shahin, M., Ahmed, B., Hamida, S. T.-B., Mulaffer, F. L., Glos, M., & Penzel, T. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2650199 · Cited by 96
Metadata
- Authors
- Anderer, P., Moreau, A., Woertz, M., Ross, M., Gruber, G., Parapatics, S., Loretz, E., Heller, E., Schmidt, A., Boeck, M., Moser, D., Kloesch, G., Saletu, B., Saletu-Zyhlarz, G. M., Danker-Hopfe, H., Zeitlhofer, J., & Dorffner, G.
- Venue
- Neuropsychobiology
- Publisher
- S. Karger AG
- Published
- 2010
- Volume
- 62
- Issue
- 4
- Pages
- 250-264
- ISSN
- 0302-282X (ISSN-L)
- 1423-0224
- OpenAlex
- W2075412305
- Cited by
- 115
- References
- 1
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer-Assisted Sleep Classification according to the Standard of the American Academy of Sleep Medicine: Validation Study of the AASM Version of the Somnolyzer 24 × 7. https://app.cochat.ai/papers/10.1159/000320864
- The paper
- Anderer, P., Moreau, A., Woertz, M., Ross, M., Gruber, G., Parapatics, S., Loretz, E., Heller, E., Schmidt, A., Boeck, M., Moser, D., Kloesch, G., Saletu, B., Saletu-Zyhlarz, G. M., Danker-Hopfe, H., Zeitlhofer, J., & Dorffner, G. (2010). Computer-Assisted Sleep Classification according to the Standard of the American Academy of Sleep Medicine: Validation Study of the AASM Version of the Somnolyzer 24 × 7. Neuropsychobiology. https://doi.org/10.1159/000320864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.