In vivo and in vitro Examination of the Tendinous Inscription of the Human Semitendinosus Muscle
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The aim of this study was to examine the tendinous inscription (TI) of the human semitendinosus (ST) muscle using dissection (cadavers) and ultrasound (in vivo). Ultrasonography (US) scans were taken in 18 young males at rest and at maximum voluntary contraction (MVC). Further, the ST was dissected and removed from its origins in 10 cadaveric specimens (5 cadavers). The cadaveric long arm of the TI was 6.67 ± 0.64 cm (6.45 ± 1.21 in US) while the shorter arm was 2.39 ± 0.38 cm (1.99 ± 0.75 in US). The angle formed by the two TI arms ranged from 53.19 (US) to 56.05° (cadavers) while more superficial fascicles intersected the inscription at significantly higher angles (range 31.98 ± 6.15 to 34.69 ± 7.71°) compared with deeper fascicles (p < 0.05). Fascicle length did not differ between compartments, but it was significantly smaller in superficial compared with deeper layers (p < 0.05). With the exception of the angle between the TI arm and the deep aponeurosis, all measured angles as well as the length of the long arm of the TI increased significantly from rest to MVC (p < 0.05). The role of the TI probably lies in the local interconnections with the fascicles of either compartment, which upon contraction is such that the ST muscle contracts as one muscle. However, the TI arm morphology changes from rest to MVC, indicating a nonuniform displacement of the TI, mainly between the superficial and deeper layers of the muscle.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Kellis et al. reported that the morphology of the tendinous inscriptions changes during rest to maximum voluntary contraction, thereby allowing a non-uniform displacement to occur and aid in movement.”
From Tendinous Inscriptions of the Rectus Abdominis: A Comprehensive Review (2018) · cites this paper as [25]
In the citing paper
“As such, other areas of the human body can have tendinous inscriptions such as the semitendinosus muscle, semispinalis capitis, splenius capitis, and the internal/external abdominal obliques muscles [24-27].”
From Tendinous Inscriptions of the Rectus Abdominis: A Comprehensive Review (2018) · cites this paper as [25]
In the citing paper
“Therefore, an association between the fascicles and tendinous inscription assists in the normal functioning of the semitendinosus muscle [25].”
From Tendinous Inscriptions of the Rectus Abdominis: A Comprehensive Review (2018) · cites this paper as [25]
In the citing paper
“This indicated that the role of the tendinous inscription lies in its connection with the muscle fascicles, such that the semitendinosus muscle contracts as one unit during contraction.”
From Tendinous Inscriptions of the Rectus Abdominis: A Comprehensive Review (2018) · cites this paper as [25]
In the citing paper
“Kellis et al. conducted an in vivo and in vitro examination of the tendinous inscriptions of the human semitendinosus muscle in 18 young males and found that all measured angles of the tendinous inscriptions of the semitendinosus muscles, with the exception of the angle between the tendinous inscription arm and the deep aponeurosis, increased significantly from rest to maximum voluntary cont”
From Tendinous Inscriptions of the Rectus Abdominis: A Comprehensive Review (2018) · cites this paper as [25]
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Ghisletta, P., & Spini, D. (2004) · Journal of Educational and Behavioral Statistics · doi:10.3102/10769986029004421 · Cited by 388 · cited 2×
“…first an examination of statistical differences between cadaveric left and right limb data, and second, the comparison of cadaveric data (n = 10) with in vivo data (n = 18), by taking into consideration the correlation between left and right limb cadaveric measurements [Ghisletta and Spini, 2004].”
MethodReal‐time sonography to estimate muscle thickness: Comparison with MRI and CT
Dupont, A., Sauerbrei, E. E., Fenton, P. V., Shragge, P. C., Loeb, G. E., & Richmond, F. J. R. (2001) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1025 · Cited by 199 · cited 1×
“The present study showed a general agreement between US and cadaveric methods ( table 3 , 5 ), which is in line with previous findings [Juul-Kristensen et al., 2000; Dupont et al., 2001; Kellis et al., 2009].”
Result
Research works printed but not linked: 30
- 10.1002%2Faja.1000060108 · DOI
- 10.1159%2F000141843 · DOI
- 10.1111%2Fj.1469-7580.2006.00619.x · DOI · Paper page
- 10.1111%2Fj.1469-7580.2010.01271.x · DOI
- 10.1097%2FBRS.0b013e31818bd6b1 · doi:10.1097/brs.0b013e31818bd6b1
- 10.1007%2FBF00229408 · DOI
- 10.1159%2F000047908 · DOI · Paper page
- 10.1002%2Fjmor.1051910207 · DOI · Paper page
- 10.1016%2F0021-9290%2890%2990373-B · DOI · Paper page
- 10.1177%2F036354658701500504 · DOI · Paper page
- 10.1002%2Fjmor.1052160106 · DOI · Paper page
- 10.1159%2F000147482 · doi:10.1159/000147482
- 10.1002%2Far.1092340406 · DOI
- 10.1016%2Fj.jbiomech.2008.09.027 · DOI · Paper page
- 10.1016%2FS0929-8266%2800%2900084-7 · DOI
- 10.1097%2F00007632-199806150-00005 · doi:10.1097/00007632-199806150-00005
- 10.1016%2Fj.jbiomech.2009.07.011 · DOI · Paper page
- 10.1148%2Frg.253045711 · DOI · Paper page
- 10.1016%2F0006-8993%2884%2990970-3 · DOI
- 10.1007%2Fs00421-007-0549-x · doi:10.1007/s00421-007-0549-x
- 10.1002%2Fjmor.1051620207 · doi:10.1002/jmor.1051620207
- 10.1007%2Fs00167-005-0701-2 · DOI
- 10.1046%2Fj.1469-7580.2001.19940429.x · doi:10.1046/j.1469-7580.2001.19940429.x
- 10.2106%2FJBJS.F.00094 · doi:10.2106/jbjs.f.00094
- 10.1007%2Fs00421-008-0980-7 · DOI · Paper page
- 10.1037%2F%2F0033-2909.86.2.420 · DOI · Paper page
- 10.1007%2FBF01560195 · DOI
- 10.1007%2Fs11999-008-0594-8 · DOI · Paper page
- 10.1097%2F00003086-198310000-00042 · DOI · Paper page
- 10.1159%2F000085004 · DOI · Paper page
Cited by
Tendinous Inscriptions of the Rectus Abdominis: A Comprehensive Review
Rai, R., Azih, L. C., Iwanaga, J., Loukas, M., Mortazavi, M., Oskouian, R. J., & Tubbs, R. S. (2018) · Cureus · doi:10.7759/cureus.3100 · Cited by 12
“As such, other areas of the human body can have tendinous inscriptions such as the semitendinosus muscle, semispinalis capitis, splenius capitis, and the internal/external abdominal obliques muscles [24-27].”
BackgroundKellis, E., & Balidou, A. (2014) · Journal of Morphology · doi:10.1002/jmor.20196 · Cited by 8
Self-citation
Metadata
- Authors
- Kellis, E., Galanis, N., Natsis, K., & Kapetanos, G.
- Venue
- Cells Tissues Organs
- Publisher
- S. Karger AG
- Published
- 2011-08-09
- Volume
- 195
- Issue
- 4
- Pages
- 365-376
- ISSN
- 1422-6405
- 1422-6421
- Cited by
- 15
- References
- 3
- Language
- en
- Licence
- www.karger.com/Services/SiteLicenses (vor)
- www.karger.com/Services/SiteLicenses (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.