CoChat

Variation in Deep Brain Stimulation Electrode Impedance over Years Following Electrode Implantation

Open access
Satzer, David, Lanctin, David, Eberly, Lynn E., Abosch, Aviva · 2014 · Stereotactic and Functional Neurosurgery
Cited by 91

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Deep brain stimulation (DBS) electrode impedance is a major determinant of current delivery to target tissues, but long-term variation in impedance has received little attention. Objectives: To assess the relationship between electrode impedance and time in a large DBS patient population and characterize the relationship between contact activity and impedance. Methods: We collected retrospective impedance and programming data from 128 electrodes in 84 patients with Parkinson's disease, essential tremor or dystonia. Effects of time, contact activity, stimulation voltage and other parameters on impedance were assessed. We also examined impedance changes following contact activation and deactivation. Results: Impedance decreased by 73 Ω/year (p < 0.001), with 72% of contacts following a downward trend. Impedance was on average 163 Ω lower in active contacts (p < 0.001). Contact activation and inactivation were associated with a more (p < 0.001) and less (p = 0.016) rapid decline in impedance, respectively. Higher stimulation voltages were associated with lower impedance values (p < 0.001). Contact number and electrode model were also significant predictors of impedance. Conclusions: Impedance decreases gradually in a stimulation-dependent manner. These trends have implications for long-term programming, the development of a closed-loop DBS device and current understanding of the electrode-tissue interface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000358014

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 91

Metadata

Authors
Satzer, D., Lanctin, D., Eberly, L. E., & Abosch, A.
Venue
Stereotactic and Functional Neurosurgery
Publisher
S. Karger AG
Published
2014
Volume
92
Issue
2
Pages
94-102
ISSN
  • 1011-6125 (ISSN-L)
  • 1423-0372
OpenAlex
W2004070622
Cited by
91
References
1
FWCI
3.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variation in Deep Brain Stimulation Electrode Impedance over Years Following Electrode Implantation. https://app.cochat.ai/papers/10.1159/000358014
The paper
Satzer, D., Lanctin, D., Eberly, L. E., & Abosch, A. (2014). Variation in Deep Brain Stimulation Electrode Impedance over Years Following Electrode Implantation. Stereotactic and Functional Neurosurgery. https://doi.org/10.1159/000358014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.