The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Binaural Hearing after Cochlear Implantation in Subjects with Unilateral Sensorineural Deafness and Tinnitus
Abstract
The aim of this clinical study was to assess speech recognition in noise after cochlear implantation in subjects with single-sided deafness and incapacitating tinnitus. 20 subjects complaining of severe intractable tinnitus unresponsive to treatment received a MED-EL cochlear implant (CI). 11 subjects had normal hearing (NH group) on the contralateral side, while 9 used a hearing aid (HA group). The subjects were tested in noise in two listening conditions, i.e. with their acoustic hearing only and with adding the CI to the acoustic hearing (binaural). Subjective improvement in daily life was evaluated using the Speech Spatial and Qualities Hearing Scale (SSQ). The summation effect (3.3 dB for the HA group and 0.6 dB for the NH group) is not significant in both groups. A significant squelch effect of adding the CI was seen for the HA users (3.8 dB), but not for the NH group (1.2 dB). Additionally, a significant effect of adding the CI was found for the spatial configuration where noise is presented in front and speech on the CI side for both the HA group (6.5 dB) and the NH group (1.7 dB). Results of the SSQ show a significant overall benefit of wearing the CI for both groups. The preliminary results of these 20 subjects suggest that cochlear implantation can improve hearing in people suffering from single-sided deafness combined with tinnitus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Speech, Spatial and Qualities of Hearing Scale (SSQ)
Gatehouse, S., & Noble, W. (2004) · International Journal of Audiology · doi:10.1080/14992020400050014 · Cited by 1,385
Sound Localization by Human Listeners
Middlebrooks, J. C., & Green, D. M. (1991) · Annual Review of Psychology · doi:10.1146/annurev.ps.42.020191.001031 · Cited by 1,210
Improving the Reliability of Testing the Speech Reception Threshold for Sentences
Plomp, R., & Mimpen, A. M. (1979) · International Journal of Audiology · doi:10.3109/00206097909072618 · Cited by 722
The effect of head-induced interaural time and level differences on speech intelligibility in noise
Bronkhorst, A. W., & Plomp, R. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.395906 · Cited by 513
Transformation of sound pressure level from the free field to the eardrum in the horizontal plane
Shaw, E. A. G. (1974) · The Journal of the Acoustical Society of America · doi:10.1121/1.1903522 · Cited by 471
Schleich, P., Nopp, P., & D’Haese, P. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000130792.43315.97 · Cited by 268
Cited by
Cochlear Implants as a Treatment Option for Unilateral Hearing Loss, Severe Tinnitus and Hyperacusis
Ramos Macías, A., Falcón González, J. C., Manrique, M., Morera, C., García-Ibáñez, L., Cenjor, C., Coudert-Koall, C., & Killian, M. (2015) · Audiology and Neurotology · doi:10.1159/000380750 · Cited by 46
Metadata
- Authors
- Vermeire, K., & Van de Heyning, P.
- Venue
- Audiology and Neurotology
- Publisher
- S. Karger AG
- Published
- 2008-11-13
- Volume
- 14
- Issue
- 3
- Pages
- 163-171
- ISSN
- 1420-3030 (ISSN-L)
- 1421-9700
- OpenAlex
- W2015335876
- Cited by
- 337
- References
- 6
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Binaural Hearing after Cochlear Implantation in Subjects with Unilateral Sensorineural Deafness and Tinnitus. https://app.cochat.ai/papers/10.1159/000171478
- The paper
- Vermeire, K., & Van de Heyning, P. (2009). Binaural Hearing after Cochlear Implantation in Subjects with Unilateral Sensorineural Deafness and Tinnitus. Audiology and Neurotology. https://doi.org/10.1159/000171478
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.