The Anaerobic Threshold: Definition, Physiological Significance and Identification
The DOI matches its Crossref record.
Abstract
During exercise, the oxygen consumption above which aerobic energy production is supplemented by anaerobic mechanisms, causing a sustained increase in lactate and metabolic acidosis, is termed the anaerobic threshold (AT). The oxygen consumption at the AT depends on factors that affect oxygen delivery to the tissues. It is increased when oxygen flow is enhanced and decreased when oxygen flow is diminished. Its value is quite low in patients with heart disease. The AT is an important functional demarcation since the physiological responses to exercise are different above the AT compared to below the AT. Above the AT, in addition to the development of metabolic acidosis, exercise endurance is reduced, VO2 kinetics are slowed so that a steady state is delayed, and VE increases disproportionately to the metabolic requirement and a progressive tachypnea develops. The AT can be measured directly from the lactate concentration with precise threshold detection from a log-log transformation of lactate and VO2. This threshold also defines the VO2 above which the lactate/pyruvate ratio increases. As bicarbonate changes reciprocally with lactate, its measurement can also be used to estimate the lactate threshold. But most convenient are gas exchange measurements made during exercise testing which can be used to noninvasively detect the lactate or anaerobic threshold. These methods are based on the physical-chemical event of buffering lactic acid with bicarbonate, and the increased CO2 output which occurs in association with the acute development of a metabolic acidosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aerobic vs anaerobic exercise training effects on the cardiovascular system
Patel, H., Alkhawam, H., Madanieh, R., Shah, N., Kosmas, C. E., & Vittorio, T. J. (2017) · World Journal of Cardiology · doi:10.4330/wjc.v9.i2.134 · Cited by 296
Cadore, E. L., Izquierdo, M., Conceição, M., Radaelli, R., Pinto, R. S., Baroni, B. M., Vaz, M. A., Alberton, C. L., Pinto, S. S., Cunha, G., et al. (2012) · Experimental Gerontology · doi:10.1016/j.exger.2012.04.002 · Cited by 237
“In addition, to confirm the data, VT2 was determined using the CO2 ventilatory equivalent (VE/VCO2) (Wasserman, 1986).”
MethodCerebral oxygenation declines at exercise intensities above the respiratory compensation threshold
Bhambhani, Y., Malik, R., & Mookerjee, S. (2007) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.08.009 · Cited by 184
Quantitative Poincar� plot analysis of heart rate variability: effect of endurance training
Mourot, L., Bouhaddi, M., Perrey, S., Rouillon, J.-D., & Regnard, J. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0917-0 · Cited by 178
“The ventilatory threshold (VT) was assessed from the relation between time of exercise and selected ventilatory parameters (RER, _ V E, _ V E/ _ V O2 and _ V E/ _ V CO2 ratios) (Wasserman 1986) by three blinded Table 1 Characteristics of the subjects.”
MethodCadore, E. L., Izquierdo, M., Pinto, S. S., Alberton, C. L., Pinto, R. S., Baroni, B. M., Vaz, M. A., Lanferdini, F. J., Radaelli, R., González-Izal, M., et al. (2013) · AGE · doi:10.1007/s11357-012-9405-y · Cited by 166
“In addition, to confirm the data, VT 2 was determined using the CO 2 ventilatory equivalent (Wasserman 1986).”
MethodMourot, L., Bouhaddi, M., Tordi, N., Rouillon, J.-D., & Regnard, J. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1119-0 · Cited by 164
“VT was assessed from the relationships between R, _V E, _V E/ _V O2 ratio, _V E/ _V CO2 ratio, and power output (Wasserman 1986) by three experts blind with respect to the condition they were evaluating.”
MethodComparison of indirect calorimetry and a new breath 13C/12C ratio method during strenuous exercise
Romijn, J. A., Coyle, E. F., Hibbert, J., & Wolfe, R. R. (1992) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1992.263.1.e64 · Cited by 110
Racinais, S., Buchheit, M., & Girard, O. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00142 · Cited by 77
Contreras-Briceño, F., Espinosa-Ramirez, M., Keim-Bagnara, V., Carreño-Román, M., Rodríguez-Villagra, R., Villegas-Belmar, F., Viscor, G., Gabrielli, L., Andía, M. E., Araneda, O. F., et al. (2022) · Life · doi:10.3390/life12030444 · Cited by 17
“…the criterion used by experienced researchers, who determine RCP considering the abrupt increase in the ventilatory equivalent of carbon dioxide production ( V̇ E· V̇ CO 2−1 ) and decrease in the pressure value at the end of CO 2 expiration (Pet-CO 2 ) during exercise, above aerobic threshold [43].”
Metadata
- Authors
- Wasserman, K.
- Venue
- Advances in Cardiology
- Publisher
- S. Karger AG
- Published
- 2015-04-16
- Volume
- 35
- Pages
- 1-23
- ISSN
- 0065-2326 (ISSN-L)
- 1662-2839
- OpenAlex
- W1665557198
- Cited by
- 139
- References
- 0
- FWCI
- 50.76
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.