Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 342

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Transbronchial Cryobiopsies for the Diagnosis of Diffuse Parenchymal Lung Diseases: Expert Statement from the Cryobiopsy Working Group on Safety and Utility and a Call for Standardization of the Procedure

Open access
Hetzel, Jürgen, Maldonado, Fabien, Ravaglia, Claudia, Wells, Athol U., Colby, Thomas V., Tomassetti, Sara, Ryu, Jay H., Fruchter, Oren, Piciucchi, Sara, Dubini, Alessandra, Cavazza, Alberto, Chilosi, Marco, Sverzellati, Nicola, Valeyre, Dominique, Leduc, Dimitri, Walsh, Simon L.F., Gasparini, Stefano, Hetzel, Martin, Hagmeyer, Lars, Haentschel, Maik, Eberhardt, Ralf, Darwiche, Kaid, Yarmus, Lonny B., Torrego, Alfonso, Krishna, Ganesh, Shah, Pallav L., Annema, Jouke T., Herth, Felix J.F., Poletti, Venerino · 2018 · Respiration

Abstract

Transbronchial cryobiopsies (TBCB) have recently been introduced as a promising and safer alternative to surgical lung biopsy in the diagnostic approach to diffuse parenchymal lung diseases (DPLD). Despite a substantial and expanding body of literature, the technique has not yet been standardized and its place in the diagnostic algorithm of DPLD remains to be defined. In part, this reflects concerns over the diagnostic yield and safety of the procedure, together with the rapid spread of the technique without competency and safety standards; furthermore, there is a substantial procedural variability among centers and interventional pulmonologists. We report this expert statement proposed during the third international conference on “Transbronchial Cryobiopsy in Diffuse Parenchymal Lung Disease” (Ravenna, October 27–28, 2016), which formulates evidence- and expert-based suggestions on the indications, contraindications, patient selection, and procedural aspects of the procedure. The following 5 domains were reviewed: (1) what is the role of TBCB in the diagnostic evaluation of DPLD: patient selection; (2) pathological considerations; (3) contraindications and safety considerations; (4) how should TBCB be performed and in what procedural environment; and (5) who should perform TBCB. Finally, the existence of white paper recommendations may also reassure local hospital credentialing committees tasked with endorsing an adoption of the technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000484055

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 342

Metadata

Authors
Hetzel, J., Maldonado, F., Ravaglia, C., Wells, A. U., Colby, T. V., Tomassetti, S., Ryu, J. H., Fruchter, O., Piciucchi, S., Dubini, A., Cavazza, A., Chilosi, M., Sverzellati, N., Valeyre, D., Leduc, D., Walsh, S. L. F., Gasparini, S., Hetzel, M., Hagmeyer, L., Haentschel, M., Eberhardt, R., Darwiche, K., Yarmus, L. B., Torrego, A., Krishna, G., Shah, P. L., Annema, J. T., Herth, F. J. F., & Poletti, V.
Venue
Respiration
Publisher
S. Karger AG
Published
2018
Volume
95
Issue
3
Pages
188-200
ISSN
  • 0025-7931 (ISSN-L)
  • 1423-0356
OpenAlex
W2784138308
Cited by
342
References
56
FWCI
33.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.