CoChat

Predictors of Outcomes in Hypoxic-Ischemic Encephalopathy following Hypothermia: A Meta-Analysis

Open access
Ouwehand, Sabine, Smidt, Lisanne C.A., Dudink, Jeroen, Benders, Manon J.N.L., de Vries, Linda S., Groenendaal, Floris, van der Aa, Niek E. · 2020 · Neonatology
Cited by 107

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Introduction: Prediction of neurodevelopmental outcome in infants with hypoxic-ischemic encephalopathy remains an important challenge. Various studies have shown that the predictive ability of different modalities changed after the introduction of therapeutic hypothermia. This paper reviews the diagnostic test accuracy of the different modalities that are being used to predict neurodevelopmental outcomes following therapeutic hypothermia. Methods: A systematic literature search was performed using Embase and PubMed. Two reviewers independently included eligible studies and extracted data. The quality of the studies was assessed using the Quality in Prognosis Studies Tool. Meta-analyses were performed where possible. Results: Forty-seven articles and 3 conference abstracts were included, reporting on 3,072infants of whom 39% died or had an adverse neurodevelopmental outcome. A meta-analysis could be performed using 37 articles on (amplitude-integrated) electroencephalography (EEG), conventional magnetic resonance imaging (MRI), diffusion-weighted imaging (DWI), and proton magnetic resonance spectroscopy (1 H-MRS). Amplitude-integrated EEG (aEEG) at 24 and 72 h showed similar high diagnostic OR, while aEEG at 6 h and EEG performed less, both due to a low specificity. For MRI, most studies reported scoring systems in which early (<8 days) MRI performed better than late (≥8 days) MRI. Injury to the posterior limb of the internal capsule on MRI or to the thalami on DWI were strong individual predictors, as was an increased lactate/N-acetylaspartate peak on 1 H-MRS. Conclusions: In the era of therapeutic hypothermia, the different modalities remain good predictors of neurodevelopmental outcome. However, timing should be taken into account. aEEG may initially be false positive and gets more reliable after 24 h. In contrast, MRI should be used during the first week, as its predictive value decreases afterwards.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000505519

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 107

Metadata

Authors
Ouwehand, S., Smidt, L. C. A., Dudink, J., Benders, M. J. N. L., de Vries, L. S., Groenendaal, F., & van der Aa, N. E.
Venue
Neonatology
Publisher
S. Karger AG
Published
2020
Volume
117
Issue
4
Pages
411-427
ISSN
  • 1661-7800 (ISSN-L)
  • 1661-7819
OpenAlex
W3014634030
Cited by
107
References
5
FWCI
4.01
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.