Cited by 6Power Quality and HarmonicsMultilevel Inverters and ConvertersElectromagnetic Compatibility and Noise Suppression

Mitigation of supply current harmonics in fuzzy-logic based 3-phase induction motor

Open access
Sivakumar, Arunachalam, Thiyagarajan, Muthamizhan, Kanagarathinam, Karthick·2023·International Journal of Power Electronics and Drive Systems (IJPEDS)

Abstract

A parallel active power filter is employed to enrich the quality of power in the power grid with non-linear loads. The induction motor drive requires better performance in many applications. The overall performance enhancement is performed by mitigating the delivery of current harmonics and related warmness losses in an induction motor. In this paper, comprehensive performance evaluation of a 3-phase induction motor is mentioned with fuzzy logic controller-based shunt active filter (SAF), and the outcomes are compared with proportional integral (PI) and proportional derivative controller (PID) controller. In this work, a new scheme of shunt active filters is connected at the supply side of the vertical speed indicator VSI fed induction motor. The simulation was performed by a fuzzy logic controller (FLC) based 3-f induction motor drive (IMD) using parallel SAF. Simulation result from MATLAB/Simulink software has been presented to understand the reduction in harmonics by introducing an active filter near the supply side. A fuzzy suitable judgment controller is brought on this work to develop the induction motor dynamic response. Analysis of the simulation outcomes, the usage of MATLAB/Simulink software program for the proposed FLC managed induction motor had been demonstrated and overall performance enhancement of induction motor was discussed.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.11591/ijpeds.v14.i1.pp266-274

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The performance of the proposed filter was analysed against the existing shunt active filter for the single-drive induction motor system.

    “The performance of proposed filter is analysed with the existing shunt active filter [30,31] for single drive induction motor system.”

    From Enriched I-Q Active Filter Based Harmonics Mitigation in Rectifier-Inverter Fed Induction Motor Drive (2025) · cites this paper as [31]

    The Control Technique section (pp. 271–272) compares a fuzzy-logic-controlled induction motor drive with PI- and PID-controlled drives, both with and without a shunt active filter. This supports a performance comparison for an induction motor drive, but the paper does not identify a distinct existing shunt active filter as the comparator. (LLM, conf=0.82)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 31

  1. W. -J. Lee, Y. Son and J. -I. Ha, "Single-phase active power filtering method using diode-rectifier-fed motor drive," IEEE Transactions on Industry Applications, vol. 51, no. 3, pp. 2227-2236, 2015, doi: 10.1109/TIA.2014.2365629. · DOI
  2. C. Qiao, K. M. Smedley and F. Maddaleno, "A single-phase active power filter with one-cycle control under unipolar operation," IEEE Transactions on Circuits and Systems I: Regular Papers, vol. 51, no. 8, pp. 1623-1630, 2004, doi: 10.1109/TCSI.2004.832801. · DOI
  3. K. K. Kumar, and R. G. Rao, "Fuzzy tuned PID controller with DQ0 reference frame technique based active power filter," International Journal of Electrical and Information Engineering, vol. 8, no. 3, pp. 640-645, 2014.
  4. H. Doğan, and R. Akkaya, "A simple control scheme for single-phase shunt active power filter with fuzzy logic based DC bus voltage controller," Proceedings of the International Multiconference of Engineers and Computer Scientists [IMECS 2009], vol. 2, PP. 1-5, 2009.
  5. L. D. Sahu and S. P. Dubey, "ANN-based hybrid active power filter for harmonics elimination with distorted mains," International Journal of Power Electronics and Drive System, vol. 2, no. 3, pp. 241-248, 2012.
  6. K. A. Siva, S. N. Muthu, "Reduction of source current harmonics in R and RL load with active filter at source end," Asian Journal of Research in Social Sciences and Humanities, vol. 6, no. 10, pp. 298-310, 2016, doi: 10.5958/2249-7315.2016.01015.7. · DOI
  7. C. L. Anooja and N. Leena, "Single-phase shunt active filter with fuzzy controller for harmonic mitigation," International Journal of Scientific & Engineering Research, vol. 4, no. 9, pp. 445-450, 2013.
  8. A. A. Stonier et al., "Fuzzy logic control for solar PV fed modular multilevel inverter towards marine water pumping applications," IEEE Access, vol. 9, pp. 88524-88534, 2021, doi: 10.1109/ACCESS.2021.3090254. · DOI
  9. F. Pottker de Souza and I. Barbi, "Single-phase active power filters for distributed power factor correction," IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018), 2000, pp. 500-505 vol. 1, doi: 10.1109/PESC.2000.878912. · DOI
  10. L. P. Kunjumuhammed and M. K. Mishra, "A control algorithm for single-phase active power filter under non-stiff voltage source," IEEE Transactions on Power Electronics, vol. 21, no. 3, pp. 822-825, 2006, doi: 10.1109/TPEL.2006.874939. · DOI
  11. D. A. Torrey and A. M. A. M. Al-Zamel, "Single-phase active power filters for multiple nonlinear loads," IEEE Transactions on Power Electronics, vol. 10, no. 3, pp. 263-272, 1995, doi: 10.1109/63.387990. · DOI
  12. H. Akagi, E. H. Watanabe, and M. Aredes, "Shunt Active Filters," Instantaneous Power Theory and Applications to Power Conditioning, John Wiley & Sons Inc, ch.4, pp. 109-216, 2007.
  13. A. Acharya, S. Murthy, V. John, and T. Saboo, "Filters for active front end motor drives," ISRO-IISC STC Symposium, ISRO- IISc Space Technology Cell project: ISTC244, pp. 1-5, 2011.
  14. T. Muthamizhan, M. Aijaz and T. Venkateswarlu, "Active shunt power filter using ANN controller for wind turbine -PMSG interfaced to grid," 2nd International Conference for Emerging Technology (INCET), 2021, pp. 1-7, doi: 10.1109/INCET51464.2021.9456123. · DOI
  15. T. Thentral, R. Rathakrishnan, V. Anbalagan, K. Dhandapani, U. Sengamalai and P. Ramasamy, "Mitigation of current harmonics in multi-drive system," International Journal of Power Electronics and Drive Systems, vol. 13, no. 1, pp. 113-121, 2022, doi: 10.11591/ijpeds.v13.i1.pp113-121. · DOI · Paper page
  16. C. S. Lam and M. C. Wong, "Design and control of hybrid active power filters," Springer, New York, ch.1-4, pp. 1-84, 2014.
  17. D. A. Mistry, B. Dheeraj, R. Gautam, M. S. Meena and S. Mikkili, "Power quality improvement using PI and fuzzy logic controller based shunt active filter," International Journal of Electronics and Communication Engineering, vol. 8, no. 4, pp. 661- 667, 2014.
  18. N. B. Muthuselvan, S. S. Dash and P. Somasundaram, "A high-performance induction motor drive system using fuzzy logic controller," TENCON 2006 -2006 IEEE Region 10 Conference, 2006, pp. 1-4, doi: 10.1109/TENCON.2006.343938. · DOI
  19. N. B. Muthuselvan, S. S. Dash and P. Somasundaram, "Artificial neural network controlled shunt active power filter," Annual IEEE India Conference, 2006, pp. 1-5, doi: 10.1109/INDCON.2006.302852. · DOI
  20. F. Mekri, M. Machmoum, N. Ait-Ahmed and B. Mazari, "Comparative study of voltage controllers for series active power filter," Electric Power Systems Research, 80, pp. 615-626, 2010.
  21. B. Singh, K. Al-Haddad and A. Chandra, "A review of active filters for power quality improvement," IEEE Transactions on Industrial Electronics, vol. 46, no. 5, pp. 960-971, 1999, doi: 10.1109/41.793345. · DOI
  22. A. Sivakumar and N. B. M. Selvan, "Harmonic analysis in induction motor drive with boost converter," International Journal of Printing, Packaging & Allied Sciences, vol.4, no.2, pp. 1159-1165, 2016.  ISSN: 2088-8694 Int J Pow Elec & Dri Syst, Vol. 14, No. 1, March 2023: 266-274 274
  23. A. Sivakumar, T. Muthamizhan, N. O. Gunasekhar, R. Ramesh, "A novel sensorless speed control strategy of induction motor based on vector control," International Review of Electrical Engineering, vol. 8, no. 4, pp. 1211-1217, 2013.
  24. W. L. Ming and Q. C. Zhong, "Current-stress reduction for the neutral inductor of θ -converters," IEEE Transactions on Power Electronics, vol. 32, no. 4, pp. 2794-2807, 2017, doi: 10.1109/TPEL.2016.2581201. · DOI
  25. Q. C. Zhong and W. L. Ming, "A θ-converter that reduces common mode currents, output voltage ripples, and total capacitance required," IEEE Transactions on Power Electronics, vol. 31, no. 12, pp. 8435-8447, 2016, doi: 10.1109/TPEL.2016.2519345. · DOI
  26. A. Sivakumar and N. B. M. Selvan, "Reduction of source current harmonics in ANN controlled induction motor," Alexandria Engineering Journal, vol. 57, no. 3, pp. 1489-1499, doi: 10.1016/j.aej.2017.03.048. · DOI
  27. N. Farah et al., "A novel self-tuning fuzzy logic controller based induction motor drive system: an experimental approach," IEEE Access, vol. 7, pp. 68172-68184, 2019, doi: 10.1109/ACCESS.2019.2916087. · DOI
  28. A. Belgacem, Y. Miloud, M. Mostefai and F. Belgacem, "Fuzzy logic direct torque control of induction motor for photovoltaic water pumping system," International Journal of Power Electronics and Drive Systems, vol. 13, no. 3, pp. 1822-1832, 2022, doi: 10.11591/ijpeds.v13.i3.pp1822-1832. · DOI
  29. M. D. Raman, C. Easwaran, V. K. Srinivasan and B. Chockalingam, "Development of performance characterization in VSI fed induction motor drives using random PWM," International Journal of Power Electronics and Drive Systems, vol. 13, no. 2, pp. 1469-1477, doi: 10.11591/ijpeds.v13.i3.pp1469-1477. · DOI
  30. S. R. Das, D. P. Mishra, P. K. Ray, S. R. Salkuti and A. K. Sahoo, "Power quality improvement using fuzzy logic-based compensation in a hybrid power system," International Journal of Power Electronics and Drive Systems, vol. 12, no. 1, pp. 576- 584, 2021, doi: 10.11591/ijpeds.v12.i1.pp576-584. · DOI
  31. G. Tahri, Z. A. Foitih and A. Tahri, "Fuzzy logic control of active and reactive power for a grid-connected photovoltaic system using a three-level neutral-point-clamped inverter," International Journal of Power Electronics and Drive System, vol. 12, no. 1, pp. 453-462, doi: 10.11591/ijpeds.v12.i1.pp453-462. · DOI

Cited by

Sorted by citations

Authors
Sivakumar, A., Thiyagarajan, M., & Kanagarathinam, K.
Venue
International Journal of Power Electronics and Drive Systems (IJPEDS)
Published
2023-03-01
Volume
14
Issue
1
Pages
266
ISSN
  • 2722-256X (ISSN-L)
  • 2088-8694
OpenAlex
W4313654676
Cited by
6
References
0
Citations by year
2025: 1 · 2024: 3 · 2023: 2
FWCI
0.45
Type
journal article
Language
en
Open access
Locations
  • International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering (publishedVersion, cc-by-sa)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
Keywords
current harmonic mitigation, fuzzy logic controller, shunt active power filter, three-phase induction motor, nonlinear loads, power quality

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review