The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hemodynamic Shear Stresses in Mouse Aortas: Implications for Atherogenesis
Abstract
Objective— The hemodynamic environment is a determinant of susceptibility to atherosclerosis in the vasculature. Although mouse models are commonly used in atherosclerosis studies, little is known about local variations in wall shear stress (WSS) in the mouse and whether the levels of WSS are comparable to those in humans. The objective of this study was to determine WSS values in the mouse aorta and to relate these to expression of gene products associated with atherosclerosis. Methods and Results— Using micro-CT and ultrasound methodologies we developed a computational fluid dynamics model of the mouse aorta and found values of WSS to be much larger than those for humans. We also used a quantum dot-based approach to study vascular cell adhesion molecule-1 and intercellular adhesion molecule-1 expression on the aortic intima and demonstrated that increased expression for these molecules occurs where WSS was relatively low for the mouse. Conclusions— Despite large differences in WSS in the two species, the spatial distributions of atherogenic molecules in the mouse aorta are similar to atherosclerotic plaque localization found in human aortas. These results suggest that relative differences in WSS or in the direction of WSS, as opposed to the absolute magnitude, may be relevant determinants of flow-mediated inflammatory responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
Rode, B., Shi, J., Endesh, N., Drinkhill, M. J., Webster, P. J., Lotteau, S. J., Bailey, M. A., Yuldasheva, N. Y., Ludlow, M. J., Cubbon, R. M., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00429-3 · Cited by 305
Xiao, H., Lu, M., Lin, T. Y., Chen, Z., Chen, G., Wang, W.-C., Marin, T., Shentu, T.-P., Wen, L., Gongol, B., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.002714 · Cited by 257
The blood clearance kinetics and pathway of polymeric micelles in cancer drug delivery
Sun, X., Wang, G., Zhang, H., Hu, S., Liu, X., Tang, J., & Shen, Y. (2018) · ACS Nano · doi:10.1021/acsnano.8b02830 · Cited by 253
Costa, P. F., Albers, H. J., Linssen, J. E. A., Middelkamp, H. H. T., van der Hout, L., Passier, R., van den Berg, A., Malda, J., & van der Meer, A. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00202e · Cited by 226
Metadata
- Authors
- Suo, J., Ferrara, D. E., Sorescu, D., Guldberg, R. E., Taylor, W. R., & Giddens, D. P.
- Venue
- Arteriosclerosis, Thrombosis, and Vascular Biology
- Published
- 2007-02
- Volume
- 27
- Issue
- 2
- Pages
- 346-351
- ISSN
- 1079-5642 (ISSN-L)
- 1524-4636
- OpenAlex
- W2157122108
- Cited by
- 294
- References
- 1
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemodynamic Shear Stresses in Mouse Aortas: Implications for Atherogenesis. https://app.cochat.ai/papers/10.1161/01.atv.0000253492.45717.46
- The paper
- Suo, J., Ferrara, D. E., Sorescu, D., Guldberg, R. E., Taylor, W. R., & Giddens, D. P. (2007). Hemodynamic Shear Stresses in Mouse Aortas: Implications for Atherogenesis. Arteriosclerosis, Thrombosis, and Vascular Biology. https://doi.org/10.1161/01.atv.0000253492.45717.46
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.