The DOI matches its Crossref record.
Micropipette aspiration of cultured bovine aortic endothelial cells exposed to shear stress.
Open accessAbstract
The mechanical properties of cultured bovine aortic endothelial cells exposed to a fluid-imposed shear stress were studied using the micropipette technique. The cells, which were attached to a Thermanox plastic substrate, were exposed to a specific steady shear stress of either 10, 30, or 85 dynes/cm2 and for a duration ranging from 0.5 to 24 hours. Morphological changes in shape and orientation were observed, and following each experiment, the mechanical properties were measured using the micropipette aspiration technique applied to cells detached from the substrate. Fluorescent microscopy was carried out to observe cytoskeletal F-actin filaments stained with rhodamine phalloidin. During exposure to shear, the en face shape of the endothelial cells on the substrate became more elongated and their long axis became oriented to the direction of flow. There was also an alteration in the F-actin filaments. These changes were dependent on both the level of shear stress and the duration of exposure. After detachment, the cells exposed to shear maintained their deformed shape. This is in contrast to cells in a static, no-flow environment which became spherical in shape upon detachment. Cells exposed to shear stress demonstrated a mechanical stiffness significantly greater than that of control cells, which was dependent on both the level of shear stress and the duration of exposure. Furthermore, it appears that the influence of shear stress on endothelial cell mechanical stiffness may be related to alterations in cytoskeletal structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Micropipette aspiration of living cells
Hochmuth, R. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00175-x · Cited by 1,423
Extracellular Matrix Rigidity Causes Strengthening of Integrin–Cytoskeleton Linkages
Choquet, D., Felsenfeld, D. P., & Sheetz, M. P. (1997) · Cell · doi:10.1016/s0092-8674(00)81856-5 · Cited by 1,245
Mechanical models for living cells—a review
Lim, C. T., Zhou, E. H., & Quek, S. T. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.12.008 · Cited by 719
Metadata
- Authors
- Sato, M., Levesque, M. J., & Nerem, R. M.
- Venue
- Arteriosclerosis: An Official Journal of the American Heart Association, Inc.
- Published
- 1987-05
- Volume
- 7
- Issue
- 3
- Pages
- 276-286
- ISSN
- 0276-5047 (ISSN-L)
- OpenAlex
- W2127696028
- Cited by
- 224
- References
- 0
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micropipette aspiration of cultured bovine aortic endothelial cells exposed to shear stress. https://app.cochat.ai/papers/10.1161/01.atv.7.3.276
- The paper
- Sato, M., Levesque, M. J., & Nerem, R. M. (1987). Micropipette aspiration of cultured bovine aortic endothelial cells exposed to shear stress. Arteriosclerosis: An Official Journal of the American Heart Association, Inc. https://doi.org/10.1161/01.atv.7.3.276
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.