In vivo modulation of endothelial F-actin microfilaments by experimental alterations in shear stress.
Open accessThe DOI matches its Crossref record.
Abstract
F-actin microfilament reorganization in response to alterations in shear stress has not been experimentally tested in vivo. In the current study, we analyzed changes in F-actin distribution in endothelial cells around the site of a coarctation performed in the midabdominal aorta of rabbits. The coarctation caused a 60% decrease in luminal diameter and produced three distinct zones: 1) a high shear region immediately upstream of the coarct (Zone I); 2) a region of low, fluctuating shear immediately downstream of the coarct (Zone II); and 3) an annular vortex characterized by high shear extending 0.5 to 3 mm downstream of the coarct (Zone III). Endothelial cells of control abdominal aortas were ellipsoid in shape and aligned in the direction of blood flow. They displayed a prominent circumferential band of microfilaments and short, thin stress fibers. Near coarctations, cells of Zone I were much more elongate, and stress fibers were markedly thicker and longer than in control abdominal aortas. In Zone II, cells were polygonal in shape and showed a prominent peripheral band of microfilaments and central stress fibers. Zone III cells were similar in shape to control abdominal aortic endothelial cells but showed very striking central stress fibers. These findings indicate that in vivo F-actin microfilament distribution can be modulated by experimentally altering flow conditions. F-actin redistribution in response to elevated shear stresses may increase cell-substrate adhesion and thus maintain endothelial integrity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“(293), who show that in the high-shear region immediately upstream of the stenosis throat, ECs are much more elongated, and stress fibers are markedly thicker and longer than in control aortas, and that in the region of low and reciprocating shear immediately downstream of the stenosis, ECs are polygonal in shape and…”
BackgroundMechanotransduction and endothelial cell homeostasis: the wisdom of the cell
Chien, S. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01047.2006 · Cited by 907
Huot, J., Houle, F., Marceau, F., & Landry, J. (1997) · Circulation Research · doi:10.1161/01.res.80.3.383 · Cited by 567
Malek, A. M., & Izumo, S. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.4.713 · Cited by 531
Metadata
- Authors
- Kim, D. W., Gotlieb, A. I., & Langille, B. L.
- Venue
- Arteriosclerosis: An Official Journal of the American Heart Association, Inc.
- Published
- 1989-07
- Volume
- 9
- Issue
- 4
- Pages
- 439-445
- ISSN
- 0276-5047 (ISSN-L)
- OpenAlex
- W2134734946
- Cited by
- 149
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo modulation of endothelial F-actin microfilaments by experimental alterations in shear stress. https://app.cochat.ai/papers/10.1161/01.atv.9.4.439
- The paper
- Kim, D. W., Gotlieb, A. I., & Langille, B. L. (1989). In vivo modulation of endothelial F-actin microfilaments by experimental alterations in shear stress. Arteriosclerosis: An Official Journal of the American Heart Association, Inc. https://doi.org/10.1161/01.atv.9.4.439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.